Immediate and early loading of hydrothermally treated, hydroxyapatite-coated dental implants: a 7-year prospective randomized clinical study

BACKGROUND: Existing research on marginal bone stability around hydroxyapatite (HA)-coated implants often lacks adequate long-term follow-up. The purpose of this randomized prospective study was to evaluate the 7-year outcome of patients with immediate and early loaded single-tooth restorations supp...

Descripción completa

Detalles Bibliográficos
Autores principales: Arghami, Afarin, Simmons, David, St. Germain, Jeanne, Maney, Pooja
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7943663/
https://www.ncbi.nlm.nih.gov/pubmed/33751297
http://dx.doi.org/10.1186/s40729-021-00299-x
_version_ 1783662540791742464
author Arghami, Afarin
Simmons, David
St. Germain, Jeanne
Maney, Pooja
author_facet Arghami, Afarin
Simmons, David
St. Germain, Jeanne
Maney, Pooja
author_sort Arghami, Afarin
collection PubMed
description BACKGROUND: Existing research on marginal bone stability around hydroxyapatite (HA)-coated implants often lacks adequate long-term follow-up. The purpose of this randomized prospective study was to evaluate the 7-year outcome of patients with immediate and early loaded single-tooth restorations supported by implants with plasma-sprayed, partially HA-coated surfaces. Forty-two patients in need of 50 single implants were treated in in the Postgraduate Periodontics Clinic of Louisiana State University School of Dentistry. Implants were randomly divided into 2 groups: Group A was immediately loaded, and Group B was early loaded. Continuous follow-up with periodic maintenance care and radiographic evaluations was performed. The primary outcome of interest was implant survival, characterized using the Kaplan–Meier method. Secondary study outcome consisted of peri-implant crestal bone level changes. Data on age, sex, bone quality, implant location, length and diameter, and prior augmentation of the site were collected. Multiple regression analyses were conducted to determine whether the independent variables were associated with bone loss. RESULTS: One implant failed to maintain stability and was removed at 3 weeks. Thirty-four patients (14 males, 20 females with a total of 42 implants) completed the 7-year follow-up visit. Average age of evaluable patients was 52 in Group A and 55 in Group B. No significant difference was observed regarding sex and age distribution between the 2 groups. No significant difference was detected in the distribution of implant locations, types of bone, implant length, implant diameter, and augmentation status of the bone between the 2 groups. After 7 years of functioning for the 42 implants examined, implant survival rate was 100% for Group A and 95.5% for Group B. The results from this study of 50 implants showed that HA-coated Zimmer Tapered Screw-Vent Implants were clinically effective, with an overall cumulative 7-year survival rate of 98.0%. When comparing radiographic bone levels between 2-year and 7-year follow-ups, no significant differences in bone loss were found between Group A and Group B. CONCLUSIONS: After 7 years in function, implants partially coated with plasma-sprayed and hydrothermally treated HA were clinically predictable when restored in occlusion immediately after or 3 weeks after implant placement.
format Online
Article
Text
id pubmed-7943663
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-79436632021-03-28 Immediate and early loading of hydrothermally treated, hydroxyapatite-coated dental implants: a 7-year prospective randomized clinical study Arghami, Afarin Simmons, David St. Germain, Jeanne Maney, Pooja Int J Implant Dent Research BACKGROUND: Existing research on marginal bone stability around hydroxyapatite (HA)-coated implants often lacks adequate long-term follow-up. The purpose of this randomized prospective study was to evaluate the 7-year outcome of patients with immediate and early loaded single-tooth restorations supported by implants with plasma-sprayed, partially HA-coated surfaces. Forty-two patients in need of 50 single implants were treated in in the Postgraduate Periodontics Clinic of Louisiana State University School of Dentistry. Implants were randomly divided into 2 groups: Group A was immediately loaded, and Group B was early loaded. Continuous follow-up with periodic maintenance care and radiographic evaluations was performed. The primary outcome of interest was implant survival, characterized using the Kaplan–Meier method. Secondary study outcome consisted of peri-implant crestal bone level changes. Data on age, sex, bone quality, implant location, length and diameter, and prior augmentation of the site were collected. Multiple regression analyses were conducted to determine whether the independent variables were associated with bone loss. RESULTS: One implant failed to maintain stability and was removed at 3 weeks. Thirty-four patients (14 males, 20 females with a total of 42 implants) completed the 7-year follow-up visit. Average age of evaluable patients was 52 in Group A and 55 in Group B. No significant difference was observed regarding sex and age distribution between the 2 groups. No significant difference was detected in the distribution of implant locations, types of bone, implant length, implant diameter, and augmentation status of the bone between the 2 groups. After 7 years of functioning for the 42 implants examined, implant survival rate was 100% for Group A and 95.5% for Group B. The results from this study of 50 implants showed that HA-coated Zimmer Tapered Screw-Vent Implants were clinically effective, with an overall cumulative 7-year survival rate of 98.0%. When comparing radiographic bone levels between 2-year and 7-year follow-ups, no significant differences in bone loss were found between Group A and Group B. CONCLUSIONS: After 7 years in function, implants partially coated with plasma-sprayed and hydrothermally treated HA were clinically predictable when restored in occlusion immediately after or 3 weeks after implant placement. Springer Berlin Heidelberg 2021-03-10 /pmc/articles/PMC7943663/ /pubmed/33751297 http://dx.doi.org/10.1186/s40729-021-00299-x Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Research
Arghami, Afarin
Simmons, David
St. Germain, Jeanne
Maney, Pooja
Immediate and early loading of hydrothermally treated, hydroxyapatite-coated dental implants: a 7-year prospective randomized clinical study
title Immediate and early loading of hydrothermally treated, hydroxyapatite-coated dental implants: a 7-year prospective randomized clinical study
title_full Immediate and early loading of hydrothermally treated, hydroxyapatite-coated dental implants: a 7-year prospective randomized clinical study
title_fullStr Immediate and early loading of hydrothermally treated, hydroxyapatite-coated dental implants: a 7-year prospective randomized clinical study
title_full_unstemmed Immediate and early loading of hydrothermally treated, hydroxyapatite-coated dental implants: a 7-year prospective randomized clinical study
title_short Immediate and early loading of hydrothermally treated, hydroxyapatite-coated dental implants: a 7-year prospective randomized clinical study
title_sort immediate and early loading of hydrothermally treated, hydroxyapatite-coated dental implants: a 7-year prospective randomized clinical study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7943663/
https://www.ncbi.nlm.nih.gov/pubmed/33751297
http://dx.doi.org/10.1186/s40729-021-00299-x
work_keys_str_mv AT arghamiafarin immediateandearlyloadingofhydrothermallytreatedhydroxyapatitecoateddentalimplantsa7yearprospectiverandomizedclinicalstudy
AT simmonsdavid immediateandearlyloadingofhydrothermallytreatedhydroxyapatitecoateddentalimplantsa7yearprospectiverandomizedclinicalstudy
AT stgermainjeanne immediateandearlyloadingofhydrothermallytreatedhydroxyapatitecoateddentalimplantsa7yearprospectiverandomizedclinicalstudy
AT maneypooja immediateandearlyloadingofhydrothermallytreatedhydroxyapatitecoateddentalimplantsa7yearprospectiverandomizedclinicalstudy