Cargando…

A thermochromic tissue-mimicking phantom model for verification of ablation plans in thermal ablation

BACKGROUND: Our study aims to develop a novel tissue-mimicking thermochromic with tumor model for visualization of thermal ablation and verification of ablation plans METHODS: Polyacrylamide gel was mixed with thermochromic ink to produce a phantom model. A phantom model embedded in a tumor model wa...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Yan, Zhao, Lin, Zhong, Xinyu, Ding, Jianmin, Zhou, Hongyu, Wang, Fengmei, Jing, Xiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7944255/
https://www.ncbi.nlm.nih.gov/pubmed/33708981
http://dx.doi.org/10.21037/atm-21-523
_version_ 1783662650087964672
author Zhou, Yan
Zhao, Lin
Zhong, Xinyu
Ding, Jianmin
Zhou, Hongyu
Wang, Fengmei
Jing, Xiang
author_facet Zhou, Yan
Zhao, Lin
Zhong, Xinyu
Ding, Jianmin
Zhou, Hongyu
Wang, Fengmei
Jing, Xiang
author_sort Zhou, Yan
collection PubMed
description BACKGROUND: Our study aims to develop a novel tissue-mimicking thermochromic with tumor model for visualization of thermal ablation and verification of ablation plans METHODS: Polyacrylamide gel was mixed with thermochromic ink to produce a phantom model. A phantom model embedded in a tumor model was constructed and used to evaluate the ablation procedure. The phantom models were randomly divided into complete ablation group and incomplete ablation group. The ablation planning of the tumor was on the 3D US and performed on a phantom model. We guide the ablation procedures according to the ablation planning. The results measured in a gross specimen of the phantom model were compared with the expected results in ablation planning. RESULTS: The color of the model changes from cream white to magenta after heating. The mono-site ablation area is a spheroid after thermal ablation with a size of 3.0×1.8 cm at 60 W, 5 minutes, 3.5×2.5 cm at 60 W, 10 minutes, and 4.0×3.5 cm at 60 W, 15 minutes, respectively. According to the ablation planning, a total of 4 ablation points were needed to retrieve the complete ablation of a 3.0 cm tumor. The complete ablation and incomplete ablation were proved by a gross specimen of the phantom model as we expected CONCLUSIONS: A novel thermochromic tissue-mimicking phantom model with a spherical tumor model has been designed and developed. The ablation area can be visualized on this phantom model by the permanent color change. This phantom model can assess the ablation planning system's accuracy and train operators for ultrasound-guided thermal ablation.
format Online
Article
Text
id pubmed-7944255
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-79442552021-03-10 A thermochromic tissue-mimicking phantom model for verification of ablation plans in thermal ablation Zhou, Yan Zhao, Lin Zhong, Xinyu Ding, Jianmin Zhou, Hongyu Wang, Fengmei Jing, Xiang Ann Transl Med Original Article BACKGROUND: Our study aims to develop a novel tissue-mimicking thermochromic with tumor model for visualization of thermal ablation and verification of ablation plans METHODS: Polyacrylamide gel was mixed with thermochromic ink to produce a phantom model. A phantom model embedded in a tumor model was constructed and used to evaluate the ablation procedure. The phantom models were randomly divided into complete ablation group and incomplete ablation group. The ablation planning of the tumor was on the 3D US and performed on a phantom model. We guide the ablation procedures according to the ablation planning. The results measured in a gross specimen of the phantom model were compared with the expected results in ablation planning. RESULTS: The color of the model changes from cream white to magenta after heating. The mono-site ablation area is a spheroid after thermal ablation with a size of 3.0×1.8 cm at 60 W, 5 minutes, 3.5×2.5 cm at 60 W, 10 minutes, and 4.0×3.5 cm at 60 W, 15 minutes, respectively. According to the ablation planning, a total of 4 ablation points were needed to retrieve the complete ablation of a 3.0 cm tumor. The complete ablation and incomplete ablation were proved by a gross specimen of the phantom model as we expected CONCLUSIONS: A novel thermochromic tissue-mimicking phantom model with a spherical tumor model has been designed and developed. The ablation area can be visualized on this phantom model by the permanent color change. This phantom model can assess the ablation planning system's accuracy and train operators for ultrasound-guided thermal ablation. AME Publishing Company 2021-02 /pmc/articles/PMC7944255/ /pubmed/33708981 http://dx.doi.org/10.21037/atm-21-523 Text en 2021 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Zhou, Yan
Zhao, Lin
Zhong, Xinyu
Ding, Jianmin
Zhou, Hongyu
Wang, Fengmei
Jing, Xiang
A thermochromic tissue-mimicking phantom model for verification of ablation plans in thermal ablation
title A thermochromic tissue-mimicking phantom model for verification of ablation plans in thermal ablation
title_full A thermochromic tissue-mimicking phantom model for verification of ablation plans in thermal ablation
title_fullStr A thermochromic tissue-mimicking phantom model for verification of ablation plans in thermal ablation
title_full_unstemmed A thermochromic tissue-mimicking phantom model for verification of ablation plans in thermal ablation
title_short A thermochromic tissue-mimicking phantom model for verification of ablation plans in thermal ablation
title_sort thermochromic tissue-mimicking phantom model for verification of ablation plans in thermal ablation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7944255/
https://www.ncbi.nlm.nih.gov/pubmed/33708981
http://dx.doi.org/10.21037/atm-21-523
work_keys_str_mv AT zhouyan athermochromictissuemimickingphantommodelforverificationofablationplansinthermalablation
AT zhaolin athermochromictissuemimickingphantommodelforverificationofablationplansinthermalablation
AT zhongxinyu athermochromictissuemimickingphantommodelforverificationofablationplansinthermalablation
AT dingjianmin athermochromictissuemimickingphantommodelforverificationofablationplansinthermalablation
AT zhouhongyu athermochromictissuemimickingphantommodelforverificationofablationplansinthermalablation
AT wangfengmei athermochromictissuemimickingphantommodelforverificationofablationplansinthermalablation
AT jingxiang athermochromictissuemimickingphantommodelforverificationofablationplansinthermalablation
AT zhouyan thermochromictissuemimickingphantommodelforverificationofablationplansinthermalablation
AT zhaolin thermochromictissuemimickingphantommodelforverificationofablationplansinthermalablation
AT zhongxinyu thermochromictissuemimickingphantommodelforverificationofablationplansinthermalablation
AT dingjianmin thermochromictissuemimickingphantommodelforverificationofablationplansinthermalablation
AT zhouhongyu thermochromictissuemimickingphantommodelforverificationofablationplansinthermalablation
AT wangfengmei thermochromictissuemimickingphantommodelforverificationofablationplansinthermalablation
AT jingxiang thermochromictissuemimickingphantommodelforverificationofablationplansinthermalablation