Cargando…
Standardization and Quality Assessment Under the Perspective of Automated Computer-Assisted HEp-2 Immunofluorescence Assay Systems
The recent availability of automated computer-assisted diagnosis (CAD) systems for the reading and interpretation of the anti-nuclear antibody (ANA) test performed with the indirect immunofluorescence (IIF) method on HEp-2 cells, has improved the reproducibility of the results and initiated a proces...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7947926/ https://www.ncbi.nlm.nih.gov/pubmed/33717188 http://dx.doi.org/10.3389/fimmu.2021.638863 |
_version_ | 1783663330045460480 |
---|---|
author | Cinquanta, Luigi Bizzaro, Nicola Pesce, Giampaola |
author_facet | Cinquanta, Luigi Bizzaro, Nicola Pesce, Giampaola |
author_sort | Cinquanta, Luigi |
collection | PubMed |
description | The recent availability of automated computer-assisted diagnosis (CAD) systems for the reading and interpretation of the anti-nuclear antibody (ANA) test performed with the indirect immunofluorescence (IIF) method on HEp-2 cells, has improved the reproducibility of the results and initiated a process of harmonization of this test. Furthermore, CAD systems provide quantitative expression of fluorescence intensity, allowing the introduction of objective quality control procedures to the monitoring of the entire process. The calibration of the reading systems and the automated image interpretation are essential prerequisites for obtaining reproducible and harmonized IIF test results and form the basis for standardization, regardless of the computer algorithms used in the different systems. The use of automated CAD systems, facilitating control procedures, represents a step forward for the quality certification of the laboratory. |
format | Online Article Text |
id | pubmed-7947926 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-79479262021-03-12 Standardization and Quality Assessment Under the Perspective of Automated Computer-Assisted HEp-2 Immunofluorescence Assay Systems Cinquanta, Luigi Bizzaro, Nicola Pesce, Giampaola Front Immunol Immunology The recent availability of automated computer-assisted diagnosis (CAD) systems for the reading and interpretation of the anti-nuclear antibody (ANA) test performed with the indirect immunofluorescence (IIF) method on HEp-2 cells, has improved the reproducibility of the results and initiated a process of harmonization of this test. Furthermore, CAD systems provide quantitative expression of fluorescence intensity, allowing the introduction of objective quality control procedures to the monitoring of the entire process. The calibration of the reading systems and the automated image interpretation are essential prerequisites for obtaining reproducible and harmonized IIF test results and form the basis for standardization, regardless of the computer algorithms used in the different systems. The use of automated CAD systems, facilitating control procedures, represents a step forward for the quality certification of the laboratory. Frontiers Media S.A. 2021-02-25 /pmc/articles/PMC7947926/ /pubmed/33717188 http://dx.doi.org/10.3389/fimmu.2021.638863 Text en Copyright © 2021 Cinquanta, Bizzaro and Pesce http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Immunology Cinquanta, Luigi Bizzaro, Nicola Pesce, Giampaola Standardization and Quality Assessment Under the Perspective of Automated Computer-Assisted HEp-2 Immunofluorescence Assay Systems |
title | Standardization and Quality Assessment Under the Perspective of Automated Computer-Assisted HEp-2 Immunofluorescence Assay Systems |
title_full | Standardization and Quality Assessment Under the Perspective of Automated Computer-Assisted HEp-2 Immunofluorescence Assay Systems |
title_fullStr | Standardization and Quality Assessment Under the Perspective of Automated Computer-Assisted HEp-2 Immunofluorescence Assay Systems |
title_full_unstemmed | Standardization and Quality Assessment Under the Perspective of Automated Computer-Assisted HEp-2 Immunofluorescence Assay Systems |
title_short | Standardization and Quality Assessment Under the Perspective of Automated Computer-Assisted HEp-2 Immunofluorescence Assay Systems |
title_sort | standardization and quality assessment under the perspective of automated computer-assisted hep-2 immunofluorescence assay systems |
topic | Immunology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7947926/ https://www.ncbi.nlm.nih.gov/pubmed/33717188 http://dx.doi.org/10.3389/fimmu.2021.638863 |
work_keys_str_mv | AT cinquantaluigi standardizationandqualityassessmentundertheperspectiveofautomatedcomputerassistedhep2immunofluorescenceassaysystems AT bizzaronicola standardizationandqualityassessmentundertheperspectiveofautomatedcomputerassistedhep2immunofluorescenceassaysystems AT pescegiampaola standardizationandqualityassessmentundertheperspectiveofautomatedcomputerassistedhep2immunofluorescenceassaysystems |