Cargando…
Dosimetric comparison between volumetric modulated arc therapy planning techniques for prostate cancer in the presence of intrafractional organ deformation
The purpose of this study was to compare single-arc (SA) and double-arc (DA) treatment plans, which are planning techniques often used in prostate cancer volumetric modulated arc therapy (VMAT), in the presence of intrafractional deformation (ID) to determine which technique is superior in terms of...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7948894/ https://www.ncbi.nlm.nih.gov/pubmed/33341880 http://dx.doi.org/10.1093/jrr/rraa123 |
_version_ | 1783663455889260544 |
---|---|
author | Varnava, Maria Sumida, Iori Oda, Michio Kurosu, Keita Isohashi, Fumiaki Seo, Yuji Otani, Keisuke Ogawa, Kazuhiko |
author_facet | Varnava, Maria Sumida, Iori Oda, Michio Kurosu, Keita Isohashi, Fumiaki Seo, Yuji Otani, Keisuke Ogawa, Kazuhiko |
author_sort | Varnava, Maria |
collection | PubMed |
description | The purpose of this study was to compare single-arc (SA) and double-arc (DA) treatment plans, which are planning techniques often used in prostate cancer volumetric modulated arc therapy (VMAT), in the presence of intrafractional deformation (ID) to determine which technique is superior in terms of target dose coverage and sparing of the organs at risk (OARs). SA and DA plans were created for 27 patients with localized prostate cancer. ID was introduced to the clinical target volume (CTV), rectum and bladder to obtain blurred dose distributions using an in-house software. ID was based on the motion probability function of each structure voxel and the intrafractional motion of the respective organs. From the resultant blurred dose distributions of SA and DA plans, various parameters, including the tumor control probability, normal tissue complication probability, homogeneity index, conformity index, modulation complexity score for VMAT, dose–volume indices and monitor units (MUs), were evaluated to compare the two techniques. Statistical analysis showed that most CTV and rectum parameters were significantly larger for SA plans than for DA plans (P < 0.05). Furthermore, SA plans had fewer MUs and were less complex (P < 0.05). The significant differences observed had no clinical significance, indicating that both plans are comparable in terms of target and OAR dosimetry when ID is considered. The use of SA plans is recommended for prostate cancer VMAT because they can be delivered in shorter treatment times than DA plans, and therefore benefit the patients. |
format | Online Article Text |
id | pubmed-7948894 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-79488942021-03-16 Dosimetric comparison between volumetric modulated arc therapy planning techniques for prostate cancer in the presence of intrafractional organ deformation Varnava, Maria Sumida, Iori Oda, Michio Kurosu, Keita Isohashi, Fumiaki Seo, Yuji Otani, Keisuke Ogawa, Kazuhiko J Radiat Res Oncology/Medicine The purpose of this study was to compare single-arc (SA) and double-arc (DA) treatment plans, which are planning techniques often used in prostate cancer volumetric modulated arc therapy (VMAT), in the presence of intrafractional deformation (ID) to determine which technique is superior in terms of target dose coverage and sparing of the organs at risk (OARs). SA and DA plans were created for 27 patients with localized prostate cancer. ID was introduced to the clinical target volume (CTV), rectum and bladder to obtain blurred dose distributions using an in-house software. ID was based on the motion probability function of each structure voxel and the intrafractional motion of the respective organs. From the resultant blurred dose distributions of SA and DA plans, various parameters, including the tumor control probability, normal tissue complication probability, homogeneity index, conformity index, modulation complexity score for VMAT, dose–volume indices and monitor units (MUs), were evaluated to compare the two techniques. Statistical analysis showed that most CTV and rectum parameters were significantly larger for SA plans than for DA plans (P < 0.05). Furthermore, SA plans had fewer MUs and were less complex (P < 0.05). The significant differences observed had no clinical significance, indicating that both plans are comparable in terms of target and OAR dosimetry when ID is considered. The use of SA plans is recommended for prostate cancer VMAT because they can be delivered in shorter treatment times than DA plans, and therefore benefit the patients. Oxford University Press 2020-12-21 /pmc/articles/PMC7948894/ /pubmed/33341880 http://dx.doi.org/10.1093/jrr/rraa123 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Oncology/Medicine Varnava, Maria Sumida, Iori Oda, Michio Kurosu, Keita Isohashi, Fumiaki Seo, Yuji Otani, Keisuke Ogawa, Kazuhiko Dosimetric comparison between volumetric modulated arc therapy planning techniques for prostate cancer in the presence of intrafractional organ deformation |
title | Dosimetric comparison between volumetric modulated arc therapy planning techniques for prostate cancer in the presence of intrafractional organ deformation |
title_full | Dosimetric comparison between volumetric modulated arc therapy planning techniques for prostate cancer in the presence of intrafractional organ deformation |
title_fullStr | Dosimetric comparison between volumetric modulated arc therapy planning techniques for prostate cancer in the presence of intrafractional organ deformation |
title_full_unstemmed | Dosimetric comparison between volumetric modulated arc therapy planning techniques for prostate cancer in the presence of intrafractional organ deformation |
title_short | Dosimetric comparison between volumetric modulated arc therapy planning techniques for prostate cancer in the presence of intrafractional organ deformation |
title_sort | dosimetric comparison between volumetric modulated arc therapy planning techniques for prostate cancer in the presence of intrafractional organ deformation |
topic | Oncology/Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7948894/ https://www.ncbi.nlm.nih.gov/pubmed/33341880 http://dx.doi.org/10.1093/jrr/rraa123 |
work_keys_str_mv | AT varnavamaria dosimetriccomparisonbetweenvolumetricmodulatedarctherapyplanningtechniquesforprostatecancerinthepresenceofintrafractionalorgandeformation AT sumidaiori dosimetriccomparisonbetweenvolumetricmodulatedarctherapyplanningtechniquesforprostatecancerinthepresenceofintrafractionalorgandeformation AT odamichio dosimetriccomparisonbetweenvolumetricmodulatedarctherapyplanningtechniquesforprostatecancerinthepresenceofintrafractionalorgandeformation AT kurosukeita dosimetriccomparisonbetweenvolumetricmodulatedarctherapyplanningtechniquesforprostatecancerinthepresenceofintrafractionalorgandeformation AT isohashifumiaki dosimetriccomparisonbetweenvolumetricmodulatedarctherapyplanningtechniquesforprostatecancerinthepresenceofintrafractionalorgandeformation AT seoyuji dosimetriccomparisonbetweenvolumetricmodulatedarctherapyplanningtechniquesforprostatecancerinthepresenceofintrafractionalorgandeformation AT otanikeisuke dosimetriccomparisonbetweenvolumetricmodulatedarctherapyplanningtechniquesforprostatecancerinthepresenceofintrafractionalorgandeformation AT ogawakazuhiko dosimetriccomparisonbetweenvolumetricmodulatedarctherapyplanningtechniquesforprostatecancerinthepresenceofintrafractionalorgandeformation |