Real-time isothermal nucleic acid amplification detection in resource-limited settings: a description of an open-source miniature fluorimeter

BACKGROUND: The detection and quantification of nucleic acids traditionally relies on PCR, which requires the use of expensive thermocyclers with integrated fluorescence detection of amplicons. While isothermal nucleic acid amplification technologies eliminate the need for thermocycling, fluorescenc...

Descripción completa

Detalles Bibliográficos
Autores principales: Coole, Jackson, Kortum, Alex, Tang, Yubo, Vohra, Imran, Natoli, Mary, Kundrod, Kathryn, Richards-Kortum, Rebecca
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license. Published by Elsevier Ltd. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7952084/
http://dx.doi.org/10.1016/S2214-109X(21)00114-5
_version_ 1783663650568929280
author Coole, Jackson
Kortum, Alex
Tang, Yubo
Vohra, Imran
Natoli, Mary
Kundrod, Kathryn
Richards-Kortum, Rebecca
author_facet Coole, Jackson
Kortum, Alex
Tang, Yubo
Vohra, Imran
Natoli, Mary
Kundrod, Kathryn
Richards-Kortum, Rebecca
author_sort Coole, Jackson
collection PubMed
description BACKGROUND: The detection and quantification of nucleic acids traditionally relies on PCR, which requires the use of expensive thermocyclers with integrated fluorescence detection of amplicons. While isothermal nucleic acid amplification technologies eliminate the need for thermocycling, fluorescence-based detection of products is still required for real-time, quantitative readout. Several commercially available isothermal heaters with integrated fluorescence detection exist, but the cost of these devices remains a significant barrier to the use of isothermal nucleic acid amplification in low-resource settings. A low-cost device for nucleic acid amplification detection could be used to contain the spread of the SARS-CoV-2 virus during the current pandemic as well as other disease targets in the future. Increasing COVID-19 testing capacity is particularly relevant when variations of the virus that appear to be more infectious are spreading rapidly and efforts to scale up delivery of COVID-19 vaccines are in the early stages. Here, we describe a modular, low-cost fluorimeter for use in resource-limited settings that lack access to and infrastructure for traditional testing platforms. METHODS: We present a fluorimeter that is constructed from off-the-shelf components enclosed in a compact 3D printed housing that removes the need for specialised optical alignment. The fluorimeter is designed to be placed atop a commercially available heat block holding a PCR-tube and was optimised to detect fluorescein (FITC) dye. The modular design allows it to be easily adapted for use with other dyes commonly used as reporters in nucleic acid amplification reactions. FINDINGS: Clinical applicability of the system was demonstrated using the system to measure amplification with two different isothermal amplification technologies with significantly different temperature, volume, and fluorescence requirements: recombinase polymerase amplification (RPA) and reverse transcription loop-mediated isothermal amplification (RT-LAMP). RPA detection was demonstrated with a positive control DNA provided in a commercial kit while RT-LAMP detection of clinically meaningful levels of SARS-CoV-2 RNA was demonstrated in a custom RT-LAMP assay. In a preliminary analysis of nasopharyngeal swab samples from 74 individuals, the custom RT-LAMP assay showed a positive agreement of 92·3% and a negative agreement of 91·4% with the SARS-CoV-2 RT-qPCR test developed by the US Centers for Disease Control and Prevention. INTERPRETATION: This open-source system was designed to improve accessibility to nucleic acid testing with isothermal amplification methods. The system can be easily produced using only a low-end 3D printer. Moreover, the use of single-board computers obviates the need to produce printed circuit boards. At a time when global supply chains are at their most fragile, open-source diagnostic equipment has the potential to reduce pandemic-related health inequities. FUNDING: International AIDS vaccine Initiative IAVI and USAID: award AID-OAA-A16-00032.
format Online
Article
Text
id pubmed-7952084
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license. Published by Elsevier Ltd.
record_format MEDLINE/PubMed
spelling pubmed-79520842021-03-12 Real-time isothermal nucleic acid amplification detection in resource-limited settings: a description of an open-source miniature fluorimeter Coole, Jackson Kortum, Alex Tang, Yubo Vohra, Imran Natoli, Mary Kundrod, Kathryn Richards-Kortum, Rebecca Lancet Glob Health Abstracts BACKGROUND: The detection and quantification of nucleic acids traditionally relies on PCR, which requires the use of expensive thermocyclers with integrated fluorescence detection of amplicons. While isothermal nucleic acid amplification technologies eliminate the need for thermocycling, fluorescence-based detection of products is still required for real-time, quantitative readout. Several commercially available isothermal heaters with integrated fluorescence detection exist, but the cost of these devices remains a significant barrier to the use of isothermal nucleic acid amplification in low-resource settings. A low-cost device for nucleic acid amplification detection could be used to contain the spread of the SARS-CoV-2 virus during the current pandemic as well as other disease targets in the future. Increasing COVID-19 testing capacity is particularly relevant when variations of the virus that appear to be more infectious are spreading rapidly and efforts to scale up delivery of COVID-19 vaccines are in the early stages. Here, we describe a modular, low-cost fluorimeter for use in resource-limited settings that lack access to and infrastructure for traditional testing platforms. METHODS: We present a fluorimeter that is constructed from off-the-shelf components enclosed in a compact 3D printed housing that removes the need for specialised optical alignment. The fluorimeter is designed to be placed atop a commercially available heat block holding a PCR-tube and was optimised to detect fluorescein (FITC) dye. The modular design allows it to be easily adapted for use with other dyes commonly used as reporters in nucleic acid amplification reactions. FINDINGS: Clinical applicability of the system was demonstrated using the system to measure amplification with two different isothermal amplification technologies with significantly different temperature, volume, and fluorescence requirements: recombinase polymerase amplification (RPA) and reverse transcription loop-mediated isothermal amplification (RT-LAMP). RPA detection was demonstrated with a positive control DNA provided in a commercial kit while RT-LAMP detection of clinically meaningful levels of SARS-CoV-2 RNA was demonstrated in a custom RT-LAMP assay. In a preliminary analysis of nasopharyngeal swab samples from 74 individuals, the custom RT-LAMP assay showed a positive agreement of 92·3% and a negative agreement of 91·4% with the SARS-CoV-2 RT-qPCR test developed by the US Centers for Disease Control and Prevention. INTERPRETATION: This open-source system was designed to improve accessibility to nucleic acid testing with isothermal amplification methods. The system can be easily produced using only a low-end 3D printer. Moreover, the use of single-board computers obviates the need to produce printed circuit boards. At a time when global supply chains are at their most fragile, open-source diagnostic equipment has the potential to reduce pandemic-related health inequities. FUNDING: International AIDS vaccine Initiative IAVI and USAID: award AID-OAA-A16-00032. The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license. Published by Elsevier Ltd. 2021-03 2021-03-11 /pmc/articles/PMC7952084/ http://dx.doi.org/10.1016/S2214-109X(21)00114-5 Text en © 2021 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Abstracts
Coole, Jackson
Kortum, Alex
Tang, Yubo
Vohra, Imran
Natoli, Mary
Kundrod, Kathryn
Richards-Kortum, Rebecca
Real-time isothermal nucleic acid amplification detection in resource-limited settings: a description of an open-source miniature fluorimeter
title Real-time isothermal nucleic acid amplification detection in resource-limited settings: a description of an open-source miniature fluorimeter
title_full Real-time isothermal nucleic acid amplification detection in resource-limited settings: a description of an open-source miniature fluorimeter
title_fullStr Real-time isothermal nucleic acid amplification detection in resource-limited settings: a description of an open-source miniature fluorimeter
title_full_unstemmed Real-time isothermal nucleic acid amplification detection in resource-limited settings: a description of an open-source miniature fluorimeter
title_short Real-time isothermal nucleic acid amplification detection in resource-limited settings: a description of an open-source miniature fluorimeter
title_sort real-time isothermal nucleic acid amplification detection in resource-limited settings: a description of an open-source miniature fluorimeter
topic Abstracts
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7952084/
http://dx.doi.org/10.1016/S2214-109X(21)00114-5
work_keys_str_mv AT coolejackson realtimeisothermalnucleicacidamplificationdetectioninresourcelimitedsettingsadescriptionofanopensourceminiaturefluorimeter
AT kortumalex realtimeisothermalnucleicacidamplificationdetectioninresourcelimitedsettingsadescriptionofanopensourceminiaturefluorimeter
AT tangyubo realtimeisothermalnucleicacidamplificationdetectioninresourcelimitedsettingsadescriptionofanopensourceminiaturefluorimeter
AT vohraimran realtimeisothermalnucleicacidamplificationdetectioninresourcelimitedsettingsadescriptionofanopensourceminiaturefluorimeter
AT natolimary realtimeisothermalnucleicacidamplificationdetectioninresourcelimitedsettingsadescriptionofanopensourceminiaturefluorimeter
AT kundrodkathryn realtimeisothermalnucleicacidamplificationdetectioninresourcelimitedsettingsadescriptionofanopensourceminiaturefluorimeter
AT richardskortumrebecca realtimeisothermalnucleicacidamplificationdetectioninresourcelimitedsettingsadescriptionofanopensourceminiaturefluorimeter