Cargando…
Robustness of a Combined Modified Dixon and PROPELLER Sequence with Two Interleaved Echoes in Clinical Head and Neck MRI
PURPOSE: The combination of modified Dixon (mDixon) and periodically rotated overlapping parallel lines with enhanced reconstruction sequence with two interleaved echoes, which promotes uniform fat-suppression and motion insensitivity, has recently become available for commercial magnetic resonance...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Japanese Society for Magnetic Resonance in Medicine
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7952203/ https://www.ncbi.nlm.nih.gov/pubmed/32269186 http://dx.doi.org/10.2463/mrms.mp.2019-0161 |
_version_ | 1783663676774940672 |
---|---|
author | Shigenaga, Yutaka Takenaka, Daisuke Hashimoto, Tomohisa Ishida, Takayuki |
author_facet | Shigenaga, Yutaka Takenaka, Daisuke Hashimoto, Tomohisa Ishida, Takayuki |
author_sort | Shigenaga, Yutaka |
collection | PubMed |
description | PURPOSE: The combination of modified Dixon (mDixon) and periodically rotated overlapping parallel lines with enhanced reconstruction sequence with two interleaved echoes, which promotes uniform fat-suppression and motion insensitivity, has recently become available for commercial magnetic resonance imaging (MRI) scanners. To compare the robustness of this combination sequence with that of standard Cartesian mDixon sequence for fat-suppressed T(2)-weighted imaging in clinical head and neck MRI. METHODS: Fifty patients with head and neck tumors were involved this study. All patients underwent MRI using both the combination and standard sequences. Two radiologists independently scored motion artifacts and water–fat separation error using a 4-point scale (1, unacceptable; 4, excellent). Furthermore, comprehensive comparative evaluation was performed using a 5-point scale (1, substantially inferior; 5, substantially superior). Data were statistically analyzed using the Wilcoxon signed-rank test. RESULTS: In the motion artifact assessment, ratings of 3 or 4 points were assigned to 45% (observer-1, 58.0%; observer-2, 32.0%) and 97% (100%; 94.0%) of images for the standard and combination sequences, respectively (P < 0.001). For the water–fat separation error assessment, ratings of 3 or 4 points were assigned to 100% (100%; 100%) and 85% (84.0%; 86.0%) of images, respectively (P < 0.001). In the comprehensive evaluation, of the 100 cases (observer-1, 50; observer-2, 50), 96 were rated at four or five points. In cases with slight or no motion artifacts and water–fat separation errors, the combination sequence was superior to the standard sequence in term of noise and sharpness, and equal in terms of contrast. CONCLUSION: Although water–fat separation errors increased significantly in the combination sequence, most of these were acceptable. The significantly decreased motion artifacts in the combination sequence significantly improved image quality overall. |
format | Online Article Text |
id | pubmed-7952203 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Japanese Society for Magnetic Resonance in Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-79522032021-03-16 Robustness of a Combined Modified Dixon and PROPELLER Sequence with Two Interleaved Echoes in Clinical Head and Neck MRI Shigenaga, Yutaka Takenaka, Daisuke Hashimoto, Tomohisa Ishida, Takayuki Magn Reson Med Sci Major Paper PURPOSE: The combination of modified Dixon (mDixon) and periodically rotated overlapping parallel lines with enhanced reconstruction sequence with two interleaved echoes, which promotes uniform fat-suppression and motion insensitivity, has recently become available for commercial magnetic resonance imaging (MRI) scanners. To compare the robustness of this combination sequence with that of standard Cartesian mDixon sequence for fat-suppressed T(2)-weighted imaging in clinical head and neck MRI. METHODS: Fifty patients with head and neck tumors were involved this study. All patients underwent MRI using both the combination and standard sequences. Two radiologists independently scored motion artifacts and water–fat separation error using a 4-point scale (1, unacceptable; 4, excellent). Furthermore, comprehensive comparative evaluation was performed using a 5-point scale (1, substantially inferior; 5, substantially superior). Data were statistically analyzed using the Wilcoxon signed-rank test. RESULTS: In the motion artifact assessment, ratings of 3 or 4 points were assigned to 45% (observer-1, 58.0%; observer-2, 32.0%) and 97% (100%; 94.0%) of images for the standard and combination sequences, respectively (P < 0.001). For the water–fat separation error assessment, ratings of 3 or 4 points were assigned to 100% (100%; 100%) and 85% (84.0%; 86.0%) of images, respectively (P < 0.001). In the comprehensive evaluation, of the 100 cases (observer-1, 50; observer-2, 50), 96 were rated at four or five points. In cases with slight or no motion artifacts and water–fat separation errors, the combination sequence was superior to the standard sequence in term of noise and sharpness, and equal in terms of contrast. CONCLUSION: Although water–fat separation errors increased significantly in the combination sequence, most of these were acceptable. The significantly decreased motion artifacts in the combination sequence significantly improved image quality overall. Japanese Society for Magnetic Resonance in Medicine 2020-04-07 /pmc/articles/PMC7952203/ /pubmed/32269186 http://dx.doi.org/10.2463/mrms.mp.2019-0161 Text en © 2021 Japanese Society for Magnetic Resonance in Medicine This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/ |
spellingShingle | Major Paper Shigenaga, Yutaka Takenaka, Daisuke Hashimoto, Tomohisa Ishida, Takayuki Robustness of a Combined Modified Dixon and PROPELLER Sequence with Two Interleaved Echoes in Clinical Head and Neck MRI |
title | Robustness of a Combined Modified Dixon and PROPELLER Sequence with Two Interleaved Echoes in Clinical Head and Neck MRI |
title_full | Robustness of a Combined Modified Dixon and PROPELLER Sequence with Two Interleaved Echoes in Clinical Head and Neck MRI |
title_fullStr | Robustness of a Combined Modified Dixon and PROPELLER Sequence with Two Interleaved Echoes in Clinical Head and Neck MRI |
title_full_unstemmed | Robustness of a Combined Modified Dixon and PROPELLER Sequence with Two Interleaved Echoes in Clinical Head and Neck MRI |
title_short | Robustness of a Combined Modified Dixon and PROPELLER Sequence with Two Interleaved Echoes in Clinical Head and Neck MRI |
title_sort | robustness of a combined modified dixon and propeller sequence with two interleaved echoes in clinical head and neck mri |
topic | Major Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7952203/ https://www.ncbi.nlm.nih.gov/pubmed/32269186 http://dx.doi.org/10.2463/mrms.mp.2019-0161 |
work_keys_str_mv | AT shigenagayutaka robustnessofacombinedmodifieddixonandpropellersequencewithtwointerleavedechoesinclinicalheadandneckmri AT takenakadaisuke robustnessofacombinedmodifieddixonandpropellersequencewithtwointerleavedechoesinclinicalheadandneckmri AT hashimototomohisa robustnessofacombinedmodifieddixonandpropellersequencewithtwointerleavedechoesinclinicalheadandneckmri AT ishidatakayuki robustnessofacombinedmodifieddixonandpropellersequencewithtwointerleavedechoesinclinicalheadandneckmri |