Cargando…

Target Detection Using Ternary Classification During a Rapid Serial Visual Presentation Task Using Magnetoencephalography Data

Background: The rapid serial visual presentation (RSVP) paradigm is a high-speed paradigm of brain–computer interface (BCI) applications. The target stimuli evoke event-related potential (ERP) activity of odd-ball effect, which can be used to detect the onsets of targets. Thus, the neural control ca...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Chuncheng, Qiu, Shuang, Wang, Shengpei, He, Huiguang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7952612/
https://www.ncbi.nlm.nih.gov/pubmed/33716702
http://dx.doi.org/10.3389/fncom.2021.619508
_version_ 1783663765410021376
author Zhang, Chuncheng
Qiu, Shuang
Wang, Shengpei
He, Huiguang
author_facet Zhang, Chuncheng
Qiu, Shuang
Wang, Shengpei
He, Huiguang
author_sort Zhang, Chuncheng
collection PubMed
description Background: The rapid serial visual presentation (RSVP) paradigm is a high-speed paradigm of brain–computer interface (BCI) applications. The target stimuli evoke event-related potential (ERP) activity of odd-ball effect, which can be used to detect the onsets of targets. Thus, the neural control can be produced by identifying the target stimulus. However, the ERPs in single trials vary in latency and length, which makes it difficult to accurately discriminate the targets against their neighbors, the near-non-targets. Thus, it reduces the efficiency of the BCI paradigm. Methods: To overcome the difficulty of ERP detection against their neighbors, we proposed a simple but novel ternary classification method to train the classifiers. The new method not only distinguished the target against all other samples but also further separated the target, near-non-target, and other, far-non-target samples. To verify the efficiency of the new method, we performed the RSVP experiment. The natural scene pictures with or without pedestrians were used; the ones with pedestrians were used as targets. Magnetoencephalography (MEG) data of 10 subjects were acquired during presentation. The SVM and CNN in EEGNet architecture classifiers were used to detect the onsets of target. Results: We obtained fairly high target detection scores using SVM and EEGNet classifiers based on MEG data. The proposed ternary classification method showed that the near-non-target samples can be discriminated from others, and the separation significantly increased the ERP detection scores in the EEGNet classifier. Moreover, the visualization of the new method suggested the different underling of SVM and EEGNet classifiers in ERP detection of the RSVP experiment. Conclusion: In the RSVP experiment, the near-non-target samples contain separable ERP activity. The ERP detection scores can be increased using classifiers of the EEGNet model, by separating the non-target into near- and far-targets based on their delay against targets.
format Online
Article
Text
id pubmed-7952612
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-79526122021-03-13 Target Detection Using Ternary Classification During a Rapid Serial Visual Presentation Task Using Magnetoencephalography Data Zhang, Chuncheng Qiu, Shuang Wang, Shengpei He, Huiguang Front Comput Neurosci Neuroscience Background: The rapid serial visual presentation (RSVP) paradigm is a high-speed paradigm of brain–computer interface (BCI) applications. The target stimuli evoke event-related potential (ERP) activity of odd-ball effect, which can be used to detect the onsets of targets. Thus, the neural control can be produced by identifying the target stimulus. However, the ERPs in single trials vary in latency and length, which makes it difficult to accurately discriminate the targets against their neighbors, the near-non-targets. Thus, it reduces the efficiency of the BCI paradigm. Methods: To overcome the difficulty of ERP detection against their neighbors, we proposed a simple but novel ternary classification method to train the classifiers. The new method not only distinguished the target against all other samples but also further separated the target, near-non-target, and other, far-non-target samples. To verify the efficiency of the new method, we performed the RSVP experiment. The natural scene pictures with or without pedestrians were used; the ones with pedestrians were used as targets. Magnetoencephalography (MEG) data of 10 subjects were acquired during presentation. The SVM and CNN in EEGNet architecture classifiers were used to detect the onsets of target. Results: We obtained fairly high target detection scores using SVM and EEGNet classifiers based on MEG data. The proposed ternary classification method showed that the near-non-target samples can be discriminated from others, and the separation significantly increased the ERP detection scores in the EEGNet classifier. Moreover, the visualization of the new method suggested the different underling of SVM and EEGNet classifiers in ERP detection of the RSVP experiment. Conclusion: In the RSVP experiment, the near-non-target samples contain separable ERP activity. The ERP detection scores can be increased using classifiers of the EEGNet model, by separating the non-target into near- and far-targets based on their delay against targets. Frontiers Media S.A. 2021-02-26 /pmc/articles/PMC7952612/ /pubmed/33716702 http://dx.doi.org/10.3389/fncom.2021.619508 Text en Copyright © 2021 Zhang, Qiu, Wang and He. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Zhang, Chuncheng
Qiu, Shuang
Wang, Shengpei
He, Huiguang
Target Detection Using Ternary Classification During a Rapid Serial Visual Presentation Task Using Magnetoencephalography Data
title Target Detection Using Ternary Classification During a Rapid Serial Visual Presentation Task Using Magnetoencephalography Data
title_full Target Detection Using Ternary Classification During a Rapid Serial Visual Presentation Task Using Magnetoencephalography Data
title_fullStr Target Detection Using Ternary Classification During a Rapid Serial Visual Presentation Task Using Magnetoencephalography Data
title_full_unstemmed Target Detection Using Ternary Classification During a Rapid Serial Visual Presentation Task Using Magnetoencephalography Data
title_short Target Detection Using Ternary Classification During a Rapid Serial Visual Presentation Task Using Magnetoencephalography Data
title_sort target detection using ternary classification during a rapid serial visual presentation task using magnetoencephalography data
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7952612/
https://www.ncbi.nlm.nih.gov/pubmed/33716702
http://dx.doi.org/10.3389/fncom.2021.619508
work_keys_str_mv AT zhangchuncheng targetdetectionusingternaryclassificationduringarapidserialvisualpresentationtaskusingmagnetoencephalographydata
AT qiushuang targetdetectionusingternaryclassificationduringarapidserialvisualpresentationtaskusingmagnetoencephalographydata
AT wangshengpei targetdetectionusingternaryclassificationduringarapidserialvisualpresentationtaskusingmagnetoencephalographydata
AT hehuiguang targetdetectionusingternaryclassificationduringarapidserialvisualpresentationtaskusingmagnetoencephalographydata