Cargando…
Measurement of ocular counter-roll using iris images during binocular fixation and head tilt
OBJECTIVE: To compare the ocular counter-roll (OCR) measured using iris images during binocular fixation and head tilt with OCR measured via fundus photography. METHODS: Fifty-three healthy college students participated in this study. The mean OCR was measured by collection of iris images and fundus...
Autores principales: | Oh, Kwang-Keun, Moon, Byeong-Yeon, Cho, Hyun Gug, Kim, Sang-Yeob, Yu, Dong-Sik |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7952848/ https://www.ncbi.nlm.nih.gov/pubmed/33719659 http://dx.doi.org/10.1177/0300060521997329 |
Ejemplares similares
-
The effect of uncorrected ametropia on ocular torsion induced by changes in fixation
por: Oh, Kwang-Keun, et al.
Publicado: (2021) -
Quantitative Evaluation of the Association Between Fixation Stability and Phoria During Short-Term Binocular Viewing
por: Kim, Sang-Yeob, et al.
Publicado: (2022) -
Effects of prolonged continuous computer gaming on physical and ocular symptoms and binocular vision functions in young healthy individuals
por: Lee, Ji-Woo, et al.
Publicado: (2019) -
No handedness effect on spatial orientation or ocular counter‐roll during lateral head tilts
por: Winnick, Ariel, et al.
Publicado: (2019) -
Use of iris pattern recognition to evaluate ocular torsional changes associated with head tilt
por: Hussein, Mohamed, et al.
Publicado: (2018)