Cargando…

Wearable Technology May Assist in Retraining Foot Strike Patterns in Previously Injured Military Service Members: A Prospective Case Series

A rearfoot strike (RFS) pattern with increased average vertical loading rates (AVLR) while running has been associated with injury. This study evaluated the ability of an instrumented sock, which provides real-time foot strike and cadence audio biofeedback, to transition previously injured military...

Descripción completa

Detalles Bibliográficos
Autores principales: Goss, Donald L., Watson, Daniel J., Miller, Erin M., Weart, Amy N., Szymanek, Eliza B., Freisinger, Gregory M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7952986/
https://www.ncbi.nlm.nih.gov/pubmed/33718868
http://dx.doi.org/10.3389/fspor.2021.630937
_version_ 1783663842735161344
author Goss, Donald L.
Watson, Daniel J.
Miller, Erin M.
Weart, Amy N.
Szymanek, Eliza B.
Freisinger, Gregory M.
author_facet Goss, Donald L.
Watson, Daniel J.
Miller, Erin M.
Weart, Amy N.
Szymanek, Eliza B.
Freisinger, Gregory M.
author_sort Goss, Donald L.
collection PubMed
description A rearfoot strike (RFS) pattern with increased average vertical loading rates (AVLR) while running has been associated with injury. This study evaluated the ability of an instrumented sock, which provides real-time foot strike and cadence audio biofeedback, to transition previously injured military service members from a RFS to a non-rearfoot strike (NRFS) running pattern. Nineteen RFS runners (10 males, 9 females) were instructed to wear the instrumented socks to facilitate a change in foot strike while completing an independent walk-to-run progression and lower extremity exercise program. Kinetic data were collected during treadmill running while foot strike was determined using video analysis at initial (T1), post-intervention (T2), and follow-up (T3) data collections. Nearly all runners (18/19) transitioned to a NRFS pattern following intervention (8 ± 2.4 weeks after the initial visit). Most participants (16/18) maintained the transition at follow-up (5 ± 0.8 weeks after the post-intervention visit). AVLR of the involved and uninvolved limb decreased 29% from initial [54.7 ± 13.2 bodyweights per sec (BW/s) and 55.1 ± 12.7 BW/s] to post-intervention (38.7 ± 10.1 BW/s and 38.9 ± 10.0 BW/s), respectively. This effect persisted 5-weeks later at follow-up, representing an overall 30% reduction on the involved limb and 24% reduction on the uninvolved limb. Cadence increased from the initial to the post-intervention time-point (p = 0.045); however, this effect did not persist at follow-up (p = 0.08). With technology provided feedback from instrumented socks, approximately 90% of participants transitioned to a NRFS pattern, decreased AVLR, reduced stance time and maintained these running adaptations 5-weeks later.
format Online
Article
Text
id pubmed-7952986
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-79529862021-03-13 Wearable Technology May Assist in Retraining Foot Strike Patterns in Previously Injured Military Service Members: A Prospective Case Series Goss, Donald L. Watson, Daniel J. Miller, Erin M. Weart, Amy N. Szymanek, Eliza B. Freisinger, Gregory M. Front Sports Act Living Sports and Active Living A rearfoot strike (RFS) pattern with increased average vertical loading rates (AVLR) while running has been associated with injury. This study evaluated the ability of an instrumented sock, which provides real-time foot strike and cadence audio biofeedback, to transition previously injured military service members from a RFS to a non-rearfoot strike (NRFS) running pattern. Nineteen RFS runners (10 males, 9 females) were instructed to wear the instrumented socks to facilitate a change in foot strike while completing an independent walk-to-run progression and lower extremity exercise program. Kinetic data were collected during treadmill running while foot strike was determined using video analysis at initial (T1), post-intervention (T2), and follow-up (T3) data collections. Nearly all runners (18/19) transitioned to a NRFS pattern following intervention (8 ± 2.4 weeks after the initial visit). Most participants (16/18) maintained the transition at follow-up (5 ± 0.8 weeks after the post-intervention visit). AVLR of the involved and uninvolved limb decreased 29% from initial [54.7 ± 13.2 bodyweights per sec (BW/s) and 55.1 ± 12.7 BW/s] to post-intervention (38.7 ± 10.1 BW/s and 38.9 ± 10.0 BW/s), respectively. This effect persisted 5-weeks later at follow-up, representing an overall 30% reduction on the involved limb and 24% reduction on the uninvolved limb. Cadence increased from the initial to the post-intervention time-point (p = 0.045); however, this effect did not persist at follow-up (p = 0.08). With technology provided feedback from instrumented socks, approximately 90% of participants transitioned to a NRFS pattern, decreased AVLR, reduced stance time and maintained these running adaptations 5-weeks later. Frontiers Media S.A. 2021-02-26 /pmc/articles/PMC7952986/ /pubmed/33718868 http://dx.doi.org/10.3389/fspor.2021.630937 Text en Copyright © 2021 Goss, Watson, Miller, Weart, Szymanek and Freisinger. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Sports and Active Living
Goss, Donald L.
Watson, Daniel J.
Miller, Erin M.
Weart, Amy N.
Szymanek, Eliza B.
Freisinger, Gregory M.
Wearable Technology May Assist in Retraining Foot Strike Patterns in Previously Injured Military Service Members: A Prospective Case Series
title Wearable Technology May Assist in Retraining Foot Strike Patterns in Previously Injured Military Service Members: A Prospective Case Series
title_full Wearable Technology May Assist in Retraining Foot Strike Patterns in Previously Injured Military Service Members: A Prospective Case Series
title_fullStr Wearable Technology May Assist in Retraining Foot Strike Patterns in Previously Injured Military Service Members: A Prospective Case Series
title_full_unstemmed Wearable Technology May Assist in Retraining Foot Strike Patterns in Previously Injured Military Service Members: A Prospective Case Series
title_short Wearable Technology May Assist in Retraining Foot Strike Patterns in Previously Injured Military Service Members: A Prospective Case Series
title_sort wearable technology may assist in retraining foot strike patterns in previously injured military service members: a prospective case series
topic Sports and Active Living
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7952986/
https://www.ncbi.nlm.nih.gov/pubmed/33718868
http://dx.doi.org/10.3389/fspor.2021.630937
work_keys_str_mv AT gossdonaldl wearabletechnologymayassistinretrainingfootstrikepatternsinpreviouslyinjuredmilitaryservicemembersaprospectivecaseseries
AT watsondanielj wearabletechnologymayassistinretrainingfootstrikepatternsinpreviouslyinjuredmilitaryservicemembersaprospectivecaseseries
AT millererinm wearabletechnologymayassistinretrainingfootstrikepatternsinpreviouslyinjuredmilitaryservicemembersaprospectivecaseseries
AT weartamyn wearabletechnologymayassistinretrainingfootstrikepatternsinpreviouslyinjuredmilitaryservicemembersaprospectivecaseseries
AT szymanekelizab wearabletechnologymayassistinretrainingfootstrikepatternsinpreviouslyinjuredmilitaryservicemembersaprospectivecaseseries
AT freisingergregorym wearabletechnologymayassistinretrainingfootstrikepatternsinpreviouslyinjuredmilitaryservicemembersaprospectivecaseseries