Sudden cardiac death after implantation of a cardiac resynchronization therapy pacemaker: a case report illustrating that not always less is more

BACKGROUND: Cardiac resynchronization therapy (CRT) improves symptoms and survival in selected patients with systolic heart failure and ventricular conduction delay. In subjects without prior life-threatening ventricular arrhythmia, clinicians have to select between implanting a CRT pacemaker (CRT-P...

Descripción completa

Detalles Bibliográficos
Autores principales: Vollmann, Dirk, Hansen, Claudius, Hunold, Peter, Lüthje, Lars
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7954243/
https://www.ncbi.nlm.nih.gov/pubmed/33738405
http://dx.doi.org/10.1093/ehjcr/ytaa540
_version_ 1783664038462357504
author Vollmann, Dirk
Hansen, Claudius
Hunold, Peter
Lüthje, Lars
author_facet Vollmann, Dirk
Hansen, Claudius
Hunold, Peter
Lüthje, Lars
author_sort Vollmann, Dirk
collection PubMed
description BACKGROUND: Cardiac resynchronization therapy (CRT) improves symptoms and survival in selected patients with systolic heart failure and ventricular conduction delay. In subjects without prior life-threatening ventricular arrhythmia, clinicians have to select between implanting a CRT pacemaker (CRT-P) or a more complex device with additional defibrillator capability (CRT-D). This individual decision can be challenging in light of the available evidence and the potential risks and benefits. CASE SUMMARY: A 76-year-old male with non-ischaemic cardiomyopathy, heart failure New York Heart Association Class III, left bundle branch block (QRS duration 185 ms) and a left ventricular ejection fraction of 30% despite optimal medical therapy was indicated for CRT. In light of the patient characteristics and clinical condition, a CRT-P device was implanted. No complication occurred, and the patient was discharged after an appropriate device function was confirmed. Despite the clinical improvement, he died suddenly without prior symptoms approximately 2 months thereafter. Post-mortem device interrogation provided no evidence for device malfunction and confirmed sudden cardiac death (SCD) due to spontaneous ventricular fibrillation. DISCUSSION: Patients indicated for CRT often have overlapping internal cardioverter defibrillator indication for the primary prevention of SCD. By weighing individual risks and potential benefits, clinicians have to decide whether to implant a CRT-P (less is more) or a more complex and costly CRT-D device. Despite careful consideration of patient characteristics and clinical conditions, however, SCD can occur in subjects categorized as low risk and implanted with a CRT-P. More data from randomized clinical trials are needed to better support physicians in the often challenging process of selecting the most appropriate device for CRT.
format Online
Article
Text
id pubmed-7954243
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-79542432021-03-17 Sudden cardiac death after implantation of a cardiac resynchronization therapy pacemaker: a case report illustrating that not always less is more Vollmann, Dirk Hansen, Claudius Hunold, Peter Lüthje, Lars Eur Heart J Case Rep Classical Case Report BACKGROUND: Cardiac resynchronization therapy (CRT) improves symptoms and survival in selected patients with systolic heart failure and ventricular conduction delay. In subjects without prior life-threatening ventricular arrhythmia, clinicians have to select between implanting a CRT pacemaker (CRT-P) or a more complex device with additional defibrillator capability (CRT-D). This individual decision can be challenging in light of the available evidence and the potential risks and benefits. CASE SUMMARY: A 76-year-old male with non-ischaemic cardiomyopathy, heart failure New York Heart Association Class III, left bundle branch block (QRS duration 185 ms) and a left ventricular ejection fraction of 30% despite optimal medical therapy was indicated for CRT. In light of the patient characteristics and clinical condition, a CRT-P device was implanted. No complication occurred, and the patient was discharged after an appropriate device function was confirmed. Despite the clinical improvement, he died suddenly without prior symptoms approximately 2 months thereafter. Post-mortem device interrogation provided no evidence for device malfunction and confirmed sudden cardiac death (SCD) due to spontaneous ventricular fibrillation. DISCUSSION: Patients indicated for CRT often have overlapping internal cardioverter defibrillator indication for the primary prevention of SCD. By weighing individual risks and potential benefits, clinicians have to decide whether to implant a CRT-P (less is more) or a more complex and costly CRT-D device. Despite careful consideration of patient characteristics and clinical conditions, however, SCD can occur in subjects categorized as low risk and implanted with a CRT-P. More data from randomized clinical trials are needed to better support physicians in the often challenging process of selecting the most appropriate device for CRT. Oxford University Press 2021-01-01 /pmc/articles/PMC7954243/ /pubmed/33738405 http://dx.doi.org/10.1093/ehjcr/ytaa540 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of the European Society of Cardiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Classical Case Report
Vollmann, Dirk
Hansen, Claudius
Hunold, Peter
Lüthje, Lars
Sudden cardiac death after implantation of a cardiac resynchronization therapy pacemaker: a case report illustrating that not always less is more
title Sudden cardiac death after implantation of a cardiac resynchronization therapy pacemaker: a case report illustrating that not always less is more
title_full Sudden cardiac death after implantation of a cardiac resynchronization therapy pacemaker: a case report illustrating that not always less is more
title_fullStr Sudden cardiac death after implantation of a cardiac resynchronization therapy pacemaker: a case report illustrating that not always less is more
title_full_unstemmed Sudden cardiac death after implantation of a cardiac resynchronization therapy pacemaker: a case report illustrating that not always less is more
title_short Sudden cardiac death after implantation of a cardiac resynchronization therapy pacemaker: a case report illustrating that not always less is more
title_sort sudden cardiac death after implantation of a cardiac resynchronization therapy pacemaker: a case report illustrating that not always less is more
topic Classical Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7954243/
https://www.ncbi.nlm.nih.gov/pubmed/33738405
http://dx.doi.org/10.1093/ehjcr/ytaa540
work_keys_str_mv AT vollmanndirk suddencardiacdeathafterimplantationofacardiacresynchronizationtherapypacemakeracasereportillustratingthatnotalwayslessismore
AT hansenclaudius suddencardiacdeathafterimplantationofacardiacresynchronizationtherapypacemakeracasereportillustratingthatnotalwayslessismore
AT hunoldpeter suddencardiacdeathafterimplantationofacardiacresynchronizationtherapypacemakeracasereportillustratingthatnotalwayslessismore
AT luthjelars suddencardiacdeathafterimplantationofacardiacresynchronizationtherapypacemakeracasereportillustratingthatnotalwayslessismore