Cargando…

Finite element analysis of double‐plate fixation using reversed locking compression‐distal femoral plates for Vancouver B1 periprosthetic femoral fractures

BACKGROUND: Internal fixation is recommended for treating Vancouver B1 periprosthetic femoral fractures. Although several fixation procedures have been developed with high fixation stability and union rates, long-term weight-bearing constructs are still lacking. Therefore, the aim of the present stu...

Descripción completa

Detalles Bibliográficos
Autores principales: Takahashi, Daisuke, Noyama, Yoshihiro, Asano, Tsuyoshi, Shimizu, Tomohiro, Irie, Tohru, Terkawi, Mohamad Alaa, Iwasaki, Norimasa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7956136/
https://www.ncbi.nlm.nih.gov/pubmed/33714273
http://dx.doi.org/10.1186/s12891-021-04152-5
_version_ 1783664374731243520
author Takahashi, Daisuke
Noyama, Yoshihiro
Asano, Tsuyoshi
Shimizu, Tomohiro
Irie, Tohru
Terkawi, Mohamad Alaa
Iwasaki, Norimasa
author_facet Takahashi, Daisuke
Noyama, Yoshihiro
Asano, Tsuyoshi
Shimizu, Tomohiro
Irie, Tohru
Terkawi, Mohamad Alaa
Iwasaki, Norimasa
author_sort Takahashi, Daisuke
collection PubMed
description BACKGROUND: Internal fixation is recommended for treating Vancouver B1 periprosthetic femoral fractures. Although several fixation procedures have been developed with high fixation stability and union rates, long-term weight-bearing constructs are still lacking. Therefore, the aim of the present study was to evaluate the stability of a double-plate procedure using reversed contralateral locking compression-distal femoral plates for fixation of Vancouver B1 periprosthetic femoral fractures under full weight-bearing. METHODS: Single- and double-plate fixation procedures for locking compression-distal femoral plates were analysed under an axial load of 1,500 N by finite element analysis and biomechanical loading tests. A vertical loading test was performed to the prosthetic head, and the displacements and strains were calculated based on load-displacement and load-strain curves generated by the static compression tests. RESULTS: The finite element analysis revealed that double-plate fixation significantly reduced stress concentration at the lateral plate place on the fracture site. Under full weight-bearing, the maximum von Mises stress in the lateral plate was 268 MPa. On the other hand, the maximum stress in the single-plating method occurred at the defect level of the femur with a maximum stress value of 1,303 MPa. The principal strains of single- and double-plate fixation were 0.63 % and 0.058 %, respectively. Consistently, in the axial loading test, the strain values at a 1,500 N loading of the single- and double-plate fixation methods were 1,274.60 ± 11.53 and 317.33 ± 8.03 (× 10(− 6)), respectively. CONCLUSIONS: The present study suggests that dual-plate fixation with reversed locking compression-distal femoral plates may be an excellent treatment procedure for patients with Vancouver B1 fractures, allowing for full weight-bearing in the early postoperative period.
format Online
Article
Text
id pubmed-7956136
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-79561362021-03-16 Finite element analysis of double‐plate fixation using reversed locking compression‐distal femoral plates for Vancouver B1 periprosthetic femoral fractures Takahashi, Daisuke Noyama, Yoshihiro Asano, Tsuyoshi Shimizu, Tomohiro Irie, Tohru Terkawi, Mohamad Alaa Iwasaki, Norimasa BMC Musculoskelet Disord Research Article BACKGROUND: Internal fixation is recommended for treating Vancouver B1 periprosthetic femoral fractures. Although several fixation procedures have been developed with high fixation stability and union rates, long-term weight-bearing constructs are still lacking. Therefore, the aim of the present study was to evaluate the stability of a double-plate procedure using reversed contralateral locking compression-distal femoral plates for fixation of Vancouver B1 periprosthetic femoral fractures under full weight-bearing. METHODS: Single- and double-plate fixation procedures for locking compression-distal femoral plates were analysed under an axial load of 1,500 N by finite element analysis and biomechanical loading tests. A vertical loading test was performed to the prosthetic head, and the displacements and strains were calculated based on load-displacement and load-strain curves generated by the static compression tests. RESULTS: The finite element analysis revealed that double-plate fixation significantly reduced stress concentration at the lateral plate place on the fracture site. Under full weight-bearing, the maximum von Mises stress in the lateral plate was 268 MPa. On the other hand, the maximum stress in the single-plating method occurred at the defect level of the femur with a maximum stress value of 1,303 MPa. The principal strains of single- and double-plate fixation were 0.63 % and 0.058 %, respectively. Consistently, in the axial loading test, the strain values at a 1,500 N loading of the single- and double-plate fixation methods were 1,274.60 ± 11.53 and 317.33 ± 8.03 (× 10(− 6)), respectively. CONCLUSIONS: The present study suggests that dual-plate fixation with reversed locking compression-distal femoral plates may be an excellent treatment procedure for patients with Vancouver B1 fractures, allowing for full weight-bearing in the early postoperative period. BioMed Central 2021-03-13 /pmc/articles/PMC7956136/ /pubmed/33714273 http://dx.doi.org/10.1186/s12891-021-04152-5 Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Takahashi, Daisuke
Noyama, Yoshihiro
Asano, Tsuyoshi
Shimizu, Tomohiro
Irie, Tohru
Terkawi, Mohamad Alaa
Iwasaki, Norimasa
Finite element analysis of double‐plate fixation using reversed locking compression‐distal femoral plates for Vancouver B1 periprosthetic femoral fractures
title Finite element analysis of double‐plate fixation using reversed locking compression‐distal femoral plates for Vancouver B1 periprosthetic femoral fractures
title_full Finite element analysis of double‐plate fixation using reversed locking compression‐distal femoral plates for Vancouver B1 periprosthetic femoral fractures
title_fullStr Finite element analysis of double‐plate fixation using reversed locking compression‐distal femoral plates for Vancouver B1 periprosthetic femoral fractures
title_full_unstemmed Finite element analysis of double‐plate fixation using reversed locking compression‐distal femoral plates for Vancouver B1 periprosthetic femoral fractures
title_short Finite element analysis of double‐plate fixation using reversed locking compression‐distal femoral plates for Vancouver B1 periprosthetic femoral fractures
title_sort finite element analysis of double‐plate fixation using reversed locking compression‐distal femoral plates for vancouver b1 periprosthetic femoral fractures
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7956136/
https://www.ncbi.nlm.nih.gov/pubmed/33714273
http://dx.doi.org/10.1186/s12891-021-04152-5
work_keys_str_mv AT takahashidaisuke finiteelementanalysisofdoubleplatefixationusingreversedlockingcompressiondistalfemoralplatesforvancouverb1periprostheticfemoralfractures
AT noyamayoshihiro finiteelementanalysisofdoubleplatefixationusingreversedlockingcompressiondistalfemoralplatesforvancouverb1periprostheticfemoralfractures
AT asanotsuyoshi finiteelementanalysisofdoubleplatefixationusingreversedlockingcompressiondistalfemoralplatesforvancouverb1periprostheticfemoralfractures
AT shimizutomohiro finiteelementanalysisofdoubleplatefixationusingreversedlockingcompressiondistalfemoralplatesforvancouverb1periprostheticfemoralfractures
AT irietohru finiteelementanalysisofdoubleplatefixationusingreversedlockingcompressiondistalfemoralplatesforvancouverb1periprostheticfemoralfractures
AT terkawimohamadalaa finiteelementanalysisofdoubleplatefixationusingreversedlockingcompressiondistalfemoralplatesforvancouverb1periprostheticfemoralfractures
AT iwasakinorimasa finiteelementanalysisofdoubleplatefixationusingreversedlockingcompressiondistalfemoralplatesforvancouverb1periprostheticfemoralfractures