Cargando…

Comparison of Tooth- and Bone-Borne Appliances on the Stress Distributions and Displacement Patterns in the Facial Skeleton in Surgically Assisted Rapid Maxillary Expansion—A Finite Element Analysis (FEA) Study

The aim of this study was to compare the reduced stresses according to Huber’s hypothesis and the displacement pattern in the region of the facial skeleton using a tooth- or bone-borne appliance in surgically assisted rapid maxillary expansion (SARME). In the current literature, the lack of updated...

Descripción completa

Detalles Bibliográficos
Autores principales: Nowak, Rafał, Olejnik, Anna, Gerber, Hanna, Frątczak, Roman, Zawiślak, Ewa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7957660/
https://www.ncbi.nlm.nih.gov/pubmed/33804454
http://dx.doi.org/10.3390/ma14051152
_version_ 1783664700013150208
author Nowak, Rafał
Olejnik, Anna
Gerber, Hanna
Frątczak, Roman
Zawiślak, Ewa
author_facet Nowak, Rafał
Olejnik, Anna
Gerber, Hanna
Frątczak, Roman
Zawiślak, Ewa
author_sort Nowak, Rafał
collection PubMed
description The aim of this study was to compare the reduced stresses according to Huber’s hypothesis and the displacement pattern in the region of the facial skeleton using a tooth- or bone-borne appliance in surgically assisted rapid maxillary expansion (SARME). In the current literature, the lack of updated reports about biomechanical effects in bone-borne appliances used in SARME is noticeable. Finite element analysis (FEA) was used for this study. Six facial skeleton models were created, five with various variants of osteotomy and one without osteotomy. Two different appliances for maxillary expansion were used for each model. The three-dimensional (3D) model of the facial skeleton was created on the basis of spiral computed tomography (CT) scans of a 32-year-old patient with maxillary constriction. The finite element model was built using ANSYS 15.0 software, in which the computations were carried out. Stress distributions and displacement values along the 3D axes were found for each osteotomy variant with the expansion of the tooth- and the bone-borne devices at a level of 0.5 mm. The investigation showed that in the case of a full osteotomy of the maxilla, as described by Bell and Epker in 1976, the method of fixing the appliance for maxillary expansion had no impact on the distribution of the reduced stresses according to Huber’s hypothesis in the facial skeleton. In the case of the bone-borne appliance, the load on the teeth, which may lead to periodontal and orthodontic complications, was eliminated. In the case of a full osteotomy of the maxilla, displacements in the buccolingual direction for all the variables of the bone-borne appliance were slightly bigger than for the tooth-borne appliance.
format Online
Article
Text
id pubmed-7957660
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79576602021-03-16 Comparison of Tooth- and Bone-Borne Appliances on the Stress Distributions and Displacement Patterns in the Facial Skeleton in Surgically Assisted Rapid Maxillary Expansion—A Finite Element Analysis (FEA) Study Nowak, Rafał Olejnik, Anna Gerber, Hanna Frątczak, Roman Zawiślak, Ewa Materials (Basel) Article The aim of this study was to compare the reduced stresses according to Huber’s hypothesis and the displacement pattern in the region of the facial skeleton using a tooth- or bone-borne appliance in surgically assisted rapid maxillary expansion (SARME). In the current literature, the lack of updated reports about biomechanical effects in bone-borne appliances used in SARME is noticeable. Finite element analysis (FEA) was used for this study. Six facial skeleton models were created, five with various variants of osteotomy and one without osteotomy. Two different appliances for maxillary expansion were used for each model. The three-dimensional (3D) model of the facial skeleton was created on the basis of spiral computed tomography (CT) scans of a 32-year-old patient with maxillary constriction. The finite element model was built using ANSYS 15.0 software, in which the computations were carried out. Stress distributions and displacement values along the 3D axes were found for each osteotomy variant with the expansion of the tooth- and the bone-borne devices at a level of 0.5 mm. The investigation showed that in the case of a full osteotomy of the maxilla, as described by Bell and Epker in 1976, the method of fixing the appliance for maxillary expansion had no impact on the distribution of the reduced stresses according to Huber’s hypothesis in the facial skeleton. In the case of the bone-borne appliance, the load on the teeth, which may lead to periodontal and orthodontic complications, was eliminated. In the case of a full osteotomy of the maxilla, displacements in the buccolingual direction for all the variables of the bone-borne appliance were slightly bigger than for the tooth-borne appliance. MDPI 2021-03-01 /pmc/articles/PMC7957660/ /pubmed/33804454 http://dx.doi.org/10.3390/ma14051152 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Nowak, Rafał
Olejnik, Anna
Gerber, Hanna
Frątczak, Roman
Zawiślak, Ewa
Comparison of Tooth- and Bone-Borne Appliances on the Stress Distributions and Displacement Patterns in the Facial Skeleton in Surgically Assisted Rapid Maxillary Expansion—A Finite Element Analysis (FEA) Study
title Comparison of Tooth- and Bone-Borne Appliances on the Stress Distributions and Displacement Patterns in the Facial Skeleton in Surgically Assisted Rapid Maxillary Expansion—A Finite Element Analysis (FEA) Study
title_full Comparison of Tooth- and Bone-Borne Appliances on the Stress Distributions and Displacement Patterns in the Facial Skeleton in Surgically Assisted Rapid Maxillary Expansion—A Finite Element Analysis (FEA) Study
title_fullStr Comparison of Tooth- and Bone-Borne Appliances on the Stress Distributions and Displacement Patterns in the Facial Skeleton in Surgically Assisted Rapid Maxillary Expansion—A Finite Element Analysis (FEA) Study
title_full_unstemmed Comparison of Tooth- and Bone-Borne Appliances on the Stress Distributions and Displacement Patterns in the Facial Skeleton in Surgically Assisted Rapid Maxillary Expansion—A Finite Element Analysis (FEA) Study
title_short Comparison of Tooth- and Bone-Borne Appliances on the Stress Distributions and Displacement Patterns in the Facial Skeleton in Surgically Assisted Rapid Maxillary Expansion—A Finite Element Analysis (FEA) Study
title_sort comparison of tooth- and bone-borne appliances on the stress distributions and displacement patterns in the facial skeleton in surgically assisted rapid maxillary expansion—a finite element analysis (fea) study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7957660/
https://www.ncbi.nlm.nih.gov/pubmed/33804454
http://dx.doi.org/10.3390/ma14051152
work_keys_str_mv AT nowakrafał comparisonoftoothandboneborneappliancesonthestressdistributionsanddisplacementpatternsinthefacialskeletoninsurgicallyassistedrapidmaxillaryexpansionafiniteelementanalysisfeastudy
AT olejnikanna comparisonoftoothandboneborneappliancesonthestressdistributionsanddisplacementpatternsinthefacialskeletoninsurgicallyassistedrapidmaxillaryexpansionafiniteelementanalysisfeastudy
AT gerberhanna comparisonoftoothandboneborneappliancesonthestressdistributionsanddisplacementpatternsinthefacialskeletoninsurgicallyassistedrapidmaxillaryexpansionafiniteelementanalysisfeastudy
AT fratczakroman comparisonoftoothandboneborneappliancesonthestressdistributionsanddisplacementpatternsinthefacialskeletoninsurgicallyassistedrapidmaxillaryexpansionafiniteelementanalysisfeastudy
AT zawislakewa comparisonoftoothandboneborneappliancesonthestressdistributionsanddisplacementpatternsinthefacialskeletoninsurgicallyassistedrapidmaxillaryexpansionafiniteelementanalysisfeastudy