Cargando…

Volume Resistivity of Viton Polymer under Thermal Aging

This study examines the influence of various electrical parameters on the volume resistivity of the Viton fluoroelastomer. The transient current, the temperature dependence of volume resistivity, the voltage dependence of resistivity, and the surface morphology of Viton insulators are investigated f...

Descripción completa

Detalles Bibliográficos
Autores principales: Abdihamzehkolaei, Alireza, Ahad, Md Tanvir, Siddique, Zahed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7959314/
https://www.ncbi.nlm.nih.gov/pubmed/33802368
http://dx.doi.org/10.3390/polym13050773
_version_ 1783664945072701440
author Abdihamzehkolaei, Alireza
Ahad, Md Tanvir
Siddique, Zahed
author_facet Abdihamzehkolaei, Alireza
Ahad, Md Tanvir
Siddique, Zahed
author_sort Abdihamzehkolaei, Alireza
collection PubMed
description This study examines the influence of various electrical parameters on the volume resistivity of the Viton fluoroelastomer. The transient current, the temperature dependence of volume resistivity, the voltage dependence of resistivity, and the surface morphology of Viton insulators are investigated for new and aged specimens. An accelerated aging process has been employed in order to simulate the natural aging of insulators in service. A detailed comparison between the new and aged samples is presented. The transient effect, which is a challenge to the resistivity measurement of insulators, has been investigated. The first 60 s of the resistivity measurement test showed a significant influence from the transient effect and should be excluded from the data. The volume resistivity of both new and aged samples decreased when the temperature increased. However, the resistivity of the aged sample was lower than the new one at all tested temperatures. When the temperature increased from 35 to 190 °C, resistivity decreased from 4.77 × 10(10) to 6.99 × 10(8) Ω-cm for the new sample and from 2.6 × 10(10) to 6.68 × 10(8) Ω-cm for the aged sample under 500 V. Additionally, the results from this study showed that the volume resistivity is inversely proportional to the applied voltage. Finally, scanning electron microscope (SEM) micrographs/images allowed us to closely examine the surface morphology of new and aged Viton samples. The surface of aged samples has been recognized with higher surface roughness and more significant surface cracks leading to poor performance under high voltage applications.
format Online
Article
Text
id pubmed-7959314
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79593142021-03-16 Volume Resistivity of Viton Polymer under Thermal Aging Abdihamzehkolaei, Alireza Ahad, Md Tanvir Siddique, Zahed Polymers (Basel) Article This study examines the influence of various electrical parameters on the volume resistivity of the Viton fluoroelastomer. The transient current, the temperature dependence of volume resistivity, the voltage dependence of resistivity, and the surface morphology of Viton insulators are investigated for new and aged specimens. An accelerated aging process has been employed in order to simulate the natural aging of insulators in service. A detailed comparison between the new and aged samples is presented. The transient effect, which is a challenge to the resistivity measurement of insulators, has been investigated. The first 60 s of the resistivity measurement test showed a significant influence from the transient effect and should be excluded from the data. The volume resistivity of both new and aged samples decreased when the temperature increased. However, the resistivity of the aged sample was lower than the new one at all tested temperatures. When the temperature increased from 35 to 190 °C, resistivity decreased from 4.77 × 10(10) to 6.99 × 10(8) Ω-cm for the new sample and from 2.6 × 10(10) to 6.68 × 10(8) Ω-cm for the aged sample under 500 V. Additionally, the results from this study showed that the volume resistivity is inversely proportional to the applied voltage. Finally, scanning electron microscope (SEM) micrographs/images allowed us to closely examine the surface morphology of new and aged Viton samples. The surface of aged samples has been recognized with higher surface roughness and more significant surface cracks leading to poor performance under high voltage applications. MDPI 2021-03-03 /pmc/articles/PMC7959314/ /pubmed/33802368 http://dx.doi.org/10.3390/polym13050773 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Abdihamzehkolaei, Alireza
Ahad, Md Tanvir
Siddique, Zahed
Volume Resistivity of Viton Polymer under Thermal Aging
title Volume Resistivity of Viton Polymer under Thermal Aging
title_full Volume Resistivity of Viton Polymer under Thermal Aging
title_fullStr Volume Resistivity of Viton Polymer under Thermal Aging
title_full_unstemmed Volume Resistivity of Viton Polymer under Thermal Aging
title_short Volume Resistivity of Viton Polymer under Thermal Aging
title_sort volume resistivity of viton polymer under thermal aging
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7959314/
https://www.ncbi.nlm.nih.gov/pubmed/33802368
http://dx.doi.org/10.3390/polym13050773
work_keys_str_mv AT abdihamzehkolaeialireza volumeresistivityofvitonpolymerunderthermalaging
AT ahadmdtanvir volumeresistivityofvitonpolymerunderthermalaging
AT siddiquezahed volumeresistivityofvitonpolymerunderthermalaging