Cargando…

The effect of capsule tension ring on posterior capsule opacification: A meta-analysis

BACKGROUND: Posterior capsule opacification is one of the most common complications after cataract surgery. Studies have suggested that the introduction of a capsule tension ring might play a critical role in the prevention of capsule opacification, yet quantitative evidence is still lacking. This w...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Kaikai, Dong, Yuchen, Zhao, Meisheng, Nie, Lili, Ding, Xinfen, Zhu, Chao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7959402/
https://www.ncbi.nlm.nih.gov/pubmed/33720958
http://dx.doi.org/10.1371/journal.pone.0246316
_version_ 1783664963106111488
author Zhang, Kaikai
Dong, Yuchen
Zhao, Meisheng
Nie, Lili
Ding, Xinfen
Zhu, Chao
author_facet Zhang, Kaikai
Dong, Yuchen
Zhao, Meisheng
Nie, Lili
Ding, Xinfen
Zhu, Chao
author_sort Zhang, Kaikai
collection PubMed
description BACKGROUND: Posterior capsule opacification is one of the most common complications after cataract surgery. Studies have suggested that the introduction of a capsule tension ring might play a critical role in the prevention of capsule opacification, yet quantitative evidence is still lacking. This work consists of a meta-analysis on available data in order to explore the influence of a capsule tension ring on posterior capsule opacification. METHODS: A comprehensive review of the literature on capsule tension ring and posterior capsule opacification was carried out using the Embase, Pubmed, Web of Science, and Cochrane electronic databases. The selected studies included randomized controlled trials, retrospective studies and prospective studies published before June 2020. The studies of interest were selected by two reviewers independently from the included studies. Odds ratios (ORs) and standardized mean differences (SMD) were used in order to assess the association. A fixed-effects model or a random-effects model was applied to combine data according to heterogeneities. Sensitivity analysis was used to assess the heterogeneity of the studies. Publication bias was estimated using the Egger test. Statistical analysis was performed using the stata15.1 software. RESULTS: The meta-analysis included in total 8 studies involving 379 cases and 333 controls. There was a statistically significant difference of Nd:YAG laser capsulotomy rate (OR=0.241, 95% CI: 0.145, 0.400 I(2)=42.1%) between the capsule tension ring group and the control group, indicating that the tension ring reduced the Nd:YAG laser capsulotomy rate. Further studies with continuous data also revealed that the use of capsule tension ring was associated with a lower posterior capsule opacification score (SMD = -1.402, 95% CI: -2.448, -0.355 I(2)=95.0%). The sensitivity analysis suggested that the result of the re-combined analysis did not change notably, indicating that the result was reliable and stable. Both pooled analysis showed no evidence of publication bias. CONCLUSION: The findings of this meta-analysis confirmed that capsule tension ring might reduce capsule opacification. Further studies should be made to validate the result.
format Online
Article
Text
id pubmed-7959402
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-79594022021-03-25 The effect of capsule tension ring on posterior capsule opacification: A meta-analysis Zhang, Kaikai Dong, Yuchen Zhao, Meisheng Nie, Lili Ding, Xinfen Zhu, Chao PLoS One Collection Review BACKGROUND: Posterior capsule opacification is one of the most common complications after cataract surgery. Studies have suggested that the introduction of a capsule tension ring might play a critical role in the prevention of capsule opacification, yet quantitative evidence is still lacking. This work consists of a meta-analysis on available data in order to explore the influence of a capsule tension ring on posterior capsule opacification. METHODS: A comprehensive review of the literature on capsule tension ring and posterior capsule opacification was carried out using the Embase, Pubmed, Web of Science, and Cochrane electronic databases. The selected studies included randomized controlled trials, retrospective studies and prospective studies published before June 2020. The studies of interest were selected by two reviewers independently from the included studies. Odds ratios (ORs) and standardized mean differences (SMD) were used in order to assess the association. A fixed-effects model or a random-effects model was applied to combine data according to heterogeneities. Sensitivity analysis was used to assess the heterogeneity of the studies. Publication bias was estimated using the Egger test. Statistical analysis was performed using the stata15.1 software. RESULTS: The meta-analysis included in total 8 studies involving 379 cases and 333 controls. There was a statistically significant difference of Nd:YAG laser capsulotomy rate (OR=0.241, 95% CI: 0.145, 0.400 I(2)=42.1%) between the capsule tension ring group and the control group, indicating that the tension ring reduced the Nd:YAG laser capsulotomy rate. Further studies with continuous data also revealed that the use of capsule tension ring was associated with a lower posterior capsule opacification score (SMD = -1.402, 95% CI: -2.448, -0.355 I(2)=95.0%). The sensitivity analysis suggested that the result of the re-combined analysis did not change notably, indicating that the result was reliable and stable. Both pooled analysis showed no evidence of publication bias. CONCLUSION: The findings of this meta-analysis confirmed that capsule tension ring might reduce capsule opacification. Further studies should be made to validate the result. Public Library of Science 2021-03-15 /pmc/articles/PMC7959402/ /pubmed/33720958 http://dx.doi.org/10.1371/journal.pone.0246316 Text en © 2021 Zhang et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Collection Review
Zhang, Kaikai
Dong, Yuchen
Zhao, Meisheng
Nie, Lili
Ding, Xinfen
Zhu, Chao
The effect of capsule tension ring on posterior capsule opacification: A meta-analysis
title The effect of capsule tension ring on posterior capsule opacification: A meta-analysis
title_full The effect of capsule tension ring on posterior capsule opacification: A meta-analysis
title_fullStr The effect of capsule tension ring on posterior capsule opacification: A meta-analysis
title_full_unstemmed The effect of capsule tension ring on posterior capsule opacification: A meta-analysis
title_short The effect of capsule tension ring on posterior capsule opacification: A meta-analysis
title_sort effect of capsule tension ring on posterior capsule opacification: a meta-analysis
topic Collection Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7959402/
https://www.ncbi.nlm.nih.gov/pubmed/33720958
http://dx.doi.org/10.1371/journal.pone.0246316
work_keys_str_mv AT zhangkaikai theeffectofcapsuletensionringonposteriorcapsuleopacificationametaanalysis
AT dongyuchen theeffectofcapsuletensionringonposteriorcapsuleopacificationametaanalysis
AT zhaomeisheng theeffectofcapsuletensionringonposteriorcapsuleopacificationametaanalysis
AT nielili theeffectofcapsuletensionringonposteriorcapsuleopacificationametaanalysis
AT dingxinfen theeffectofcapsuletensionringonposteriorcapsuleopacificationametaanalysis
AT zhuchao theeffectofcapsuletensionringonposteriorcapsuleopacificationametaanalysis
AT zhangkaikai effectofcapsuletensionringonposteriorcapsuleopacificationametaanalysis
AT dongyuchen effectofcapsuletensionringonposteriorcapsuleopacificationametaanalysis
AT zhaomeisheng effectofcapsuletensionringonposteriorcapsuleopacificationametaanalysis
AT nielili effectofcapsuletensionringonposteriorcapsuleopacificationametaanalysis
AT dingxinfen effectofcapsuletensionringonposteriorcapsuleopacificationametaanalysis
AT zhuchao effectofcapsuletensionringonposteriorcapsuleopacificationametaanalysis