A Comparative Study on Aqueous Chitosan Solution and Various Submucosal Injection Fluids Using a Three-Dimensional Sensor
BACKGROUND/AIMS: Chitosan, a natural polymer widely used in the biomaterials field, has been proposed as a potential submucosal injection solution. The purpose of this study was to compare the performance and efficacy of aqueous chitosan solution and commercialized submucosal injection fluids using...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Editorial Office of Gut and Liver
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7960965/ https://www.ncbi.nlm.nih.gov/pubmed/32390408 http://dx.doi.org/10.5009/gnl19383 |
Sumario: | BACKGROUND/AIMS: Chitosan, a natural polymer widely used in the biomaterials field, has been proposed as a potential submucosal injection solution. The purpose of this study was to compare the performance and efficacy of aqueous chitosan solution and commercialized submucosal injection fluids using a three-dimensional sensor and to evaluate the efficacy of the measured parameters. METHODS: Normal saline (0.9% NaCl), as a control, Eleview(®) (Poloxamer 188), Blue Eye(TM) (0.4% hyaluronic acid), and aqueous chitosan solution (2.0%) were injected into the submucosa of porcine stomachs ex vivo. The mucosal elevation height, elevated surface area, and angle of the tangent of the submucosal fluid cushion were measured using a three-dimensional sensor. The rates of change for each variable were calculated, and the correlation between parameters was analyzed. Tissue specimens were stained with hematoxylin and eosin. RESULTS: All variables exhibited the highest values under chitosan injection. The mucosal elevation height rate of change differed significantly between normal saline and chitosan solution (p=0.024). The elevated surface area rates of change for normal saline and Eleview(®) were significantly different from those for TS-905 and chitosan solution (p=0.006 and p=0.009, respectively). Further, height, area, and angle showed a positive correlation (p<0.001). A histological examination revealed an even distribution of aqueous chitosan within the submucosa without tissue damage. CONCLUSIONS: Aqueous chitosan was superior to normal saline and Eleview(®) and was noninferior to TS-905. A three-dimensional sensor and the measured parameters were effective and useful for evaluating the performance of submucosal fluids. |
---|