Cargando…

Comparison of new implantation of cardiac implantable electronic device between tertiary and non-tertiary hospitals: a Korean nationwide study

This study compared the characteristics and mortality of new implantation of cardiac implantable electronic device (CIED) between tertiary and non-tertiary hospitals. From national health insurance claims data in Korea, 17,655 patients, who underwent first and new implantation of CIED between 2013 a...

Descripción completa

Detalles Bibliográficos
Autores principales: Han, Seungbong, Park, Gyung-Min, Kim, Yong-Giun, Hwang, Ki Won, Kwon, Chang Hee, Roh, Jae-Hyung, Park, Sangwoo, Won, Ki-Bum, Ann, Soe Hee, Kim, Shin-Jae, Lee, Sang-Gon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7961055/
https://www.ncbi.nlm.nih.gov/pubmed/33723278
http://dx.doi.org/10.1038/s41598-021-83160-w
_version_ 1783665174450798592
author Han, Seungbong
Park, Gyung-Min
Kim, Yong-Giun
Hwang, Ki Won
Kwon, Chang Hee
Roh, Jae-Hyung
Park, Sangwoo
Won, Ki-Bum
Ann, Soe Hee
Kim, Shin-Jae
Lee, Sang-Gon
author_facet Han, Seungbong
Park, Gyung-Min
Kim, Yong-Giun
Hwang, Ki Won
Kwon, Chang Hee
Roh, Jae-Hyung
Park, Sangwoo
Won, Ki-Bum
Ann, Soe Hee
Kim, Shin-Jae
Lee, Sang-Gon
author_sort Han, Seungbong
collection PubMed
description This study compared the characteristics and mortality of new implantation of cardiac implantable electronic device (CIED) between tertiary and non-tertiary hospitals. From national health insurance claims data in Korea, 17,655 patients, who underwent first and new implantation of CIED between 2013 and 2017, were enrolled. Patients were categorized into the tertiary hospital group (n = 11,560) and non-tertiary hospital group (n = 6095). Clinical outcomes including in-hospital death and all-cause death were compared between the two groups using propensity-score matched analysis. Patients in non-tertiary hospitals were older and had more comorbidities than those in tertiary hospitals. The study population had a mean follow-up of 2.1 ± 1.2 years. In the propensity-score matched permanent pacemaker group (n = 5076 pairs), the incidence of in-hospital death (odds ratio [OR]: 0.76, 95% confidence interval [CI]: 0.43–1.32, p = 0.33) and all-cause death (hazard ratio [HR]: 0.92, 95% CI 0.81–1.05, p = 0.24) were not significantly different between tertiary and non-tertiary hospitals. These findings were consistently observed in the propensity-score matched implantable cardioverter-defibrillator group (n = 992 pairs, OR for in-hospital death: 1.76, 95% CI 0.51–6.02, p = 0.37; HR for all-cause death: 0.95, 95% CI 0.72–1.24, p = 0.70). In patients undergoing first and new implantation of CIED in Korea, mortality was not different between tertiary and non-tertiary hospitals.
format Online
Article
Text
id pubmed-7961055
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-79610552021-03-19 Comparison of new implantation of cardiac implantable electronic device between tertiary and non-tertiary hospitals: a Korean nationwide study Han, Seungbong Park, Gyung-Min Kim, Yong-Giun Hwang, Ki Won Kwon, Chang Hee Roh, Jae-Hyung Park, Sangwoo Won, Ki-Bum Ann, Soe Hee Kim, Shin-Jae Lee, Sang-Gon Sci Rep Article This study compared the characteristics and mortality of new implantation of cardiac implantable electronic device (CIED) between tertiary and non-tertiary hospitals. From national health insurance claims data in Korea, 17,655 patients, who underwent first and new implantation of CIED between 2013 and 2017, were enrolled. Patients were categorized into the tertiary hospital group (n = 11,560) and non-tertiary hospital group (n = 6095). Clinical outcomes including in-hospital death and all-cause death were compared between the two groups using propensity-score matched analysis. Patients in non-tertiary hospitals were older and had more comorbidities than those in tertiary hospitals. The study population had a mean follow-up of 2.1 ± 1.2 years. In the propensity-score matched permanent pacemaker group (n = 5076 pairs), the incidence of in-hospital death (odds ratio [OR]: 0.76, 95% confidence interval [CI]: 0.43–1.32, p = 0.33) and all-cause death (hazard ratio [HR]: 0.92, 95% CI 0.81–1.05, p = 0.24) were not significantly different between tertiary and non-tertiary hospitals. These findings were consistently observed in the propensity-score matched implantable cardioverter-defibrillator group (n = 992 pairs, OR for in-hospital death: 1.76, 95% CI 0.51–6.02, p = 0.37; HR for all-cause death: 0.95, 95% CI 0.72–1.24, p = 0.70). In patients undergoing first and new implantation of CIED in Korea, mortality was not different between tertiary and non-tertiary hospitals. Nature Publishing Group UK 2021-03-15 /pmc/articles/PMC7961055/ /pubmed/33723278 http://dx.doi.org/10.1038/s41598-021-83160-w Text en © The Author(s) 2021 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Han, Seungbong
Park, Gyung-Min
Kim, Yong-Giun
Hwang, Ki Won
Kwon, Chang Hee
Roh, Jae-Hyung
Park, Sangwoo
Won, Ki-Bum
Ann, Soe Hee
Kim, Shin-Jae
Lee, Sang-Gon
Comparison of new implantation of cardiac implantable electronic device between tertiary and non-tertiary hospitals: a Korean nationwide study
title Comparison of new implantation of cardiac implantable electronic device between tertiary and non-tertiary hospitals: a Korean nationwide study
title_full Comparison of new implantation of cardiac implantable electronic device between tertiary and non-tertiary hospitals: a Korean nationwide study
title_fullStr Comparison of new implantation of cardiac implantable electronic device between tertiary and non-tertiary hospitals: a Korean nationwide study
title_full_unstemmed Comparison of new implantation of cardiac implantable electronic device between tertiary and non-tertiary hospitals: a Korean nationwide study
title_short Comparison of new implantation of cardiac implantable electronic device between tertiary and non-tertiary hospitals: a Korean nationwide study
title_sort comparison of new implantation of cardiac implantable electronic device between tertiary and non-tertiary hospitals: a korean nationwide study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7961055/
https://www.ncbi.nlm.nih.gov/pubmed/33723278
http://dx.doi.org/10.1038/s41598-021-83160-w
work_keys_str_mv AT hanseungbong comparisonofnewimplantationofcardiacimplantableelectronicdevicebetweentertiaryandnontertiaryhospitalsakoreannationwidestudy
AT parkgyungmin comparisonofnewimplantationofcardiacimplantableelectronicdevicebetweentertiaryandnontertiaryhospitalsakoreannationwidestudy
AT kimyonggiun comparisonofnewimplantationofcardiacimplantableelectronicdevicebetweentertiaryandnontertiaryhospitalsakoreannationwidestudy
AT hwangkiwon comparisonofnewimplantationofcardiacimplantableelectronicdevicebetweentertiaryandnontertiaryhospitalsakoreannationwidestudy
AT kwonchanghee comparisonofnewimplantationofcardiacimplantableelectronicdevicebetweentertiaryandnontertiaryhospitalsakoreannationwidestudy
AT rohjaehyung comparisonofnewimplantationofcardiacimplantableelectronicdevicebetweentertiaryandnontertiaryhospitalsakoreannationwidestudy
AT parksangwoo comparisonofnewimplantationofcardiacimplantableelectronicdevicebetweentertiaryandnontertiaryhospitalsakoreannationwidestudy
AT wonkibum comparisonofnewimplantationofcardiacimplantableelectronicdevicebetweentertiaryandnontertiaryhospitalsakoreannationwidestudy
AT annsoehee comparisonofnewimplantationofcardiacimplantableelectronicdevicebetweentertiaryandnontertiaryhospitalsakoreannationwidestudy
AT kimshinjae comparisonofnewimplantationofcardiacimplantableelectronicdevicebetweentertiaryandnontertiaryhospitalsakoreannationwidestudy
AT leesanggon comparisonofnewimplantationofcardiacimplantableelectronicdevicebetweentertiaryandnontertiaryhospitalsakoreannationwidestudy