Cargando…

Direct and indirect evidence of efficacy and safety of rapid exercise tests for exertional desaturation in Covid-19: a rapid systematic review

BACKGROUND: Even when resting pulse oximetry is normal in the patient with acute Covid-19, hypoxia can manifest on exertion. We summarise the literature on the performance of different rapid tests for exertional desaturation and draw on this evidence base to provide guidance in the context of acute...

Descripción completa

Detalles Bibliográficos
Autores principales: Kalin, Asli, Javid, Babak, Knight, Matthew, Inada-Kim, Matt, Greenhalgh, Trisha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7961172/
https://www.ncbi.nlm.nih.gov/pubmed/33726854
http://dx.doi.org/10.1186/s13643-021-01620-w
_version_ 1783665201361453056
author Kalin, Asli
Javid, Babak
Knight, Matthew
Inada-Kim, Matt
Greenhalgh, Trisha
author_facet Kalin, Asli
Javid, Babak
Knight, Matthew
Inada-Kim, Matt
Greenhalgh, Trisha
author_sort Kalin, Asli
collection PubMed
description BACKGROUND: Even when resting pulse oximetry is normal in the patient with acute Covid-19, hypoxia can manifest on exertion. We summarise the literature on the performance of different rapid tests for exertional desaturation and draw on this evidence base to provide guidance in the context of acute Covid-19. MAIN RESEARCH QUESTIONS: 1. What exercise tests have been used to assess exertional hypoxia at home or in an ambulatory setting in the context of Covid-19 and to what extent have they been validated? 2. What exercise tests have been used to assess exertional hypoxia in other lung conditions, to what extent have they been validated and what is the applicability of these studies to acute Covid-19? METHOD: AMED, CINAHL, EMBASE MEDLINE, Cochrane and PubMed using LitCovid, Scholar and Google databases were searched to September 2020. Studies where participants had Covid-19 or another lung disease and underwent any form of exercise test which was compared to a reference standard were eligible. Risk of bias was assessed using QUADAS 2. A protocol for the review was published on the Medrxiv database. RESULTS: Of 47 relevant papers, 15 were empirical studies, of which 11 described an attempt to validate one or more exercise desaturation tests in lung diseases other than Covid-19. In all but one of these, methodological quality was poor or impossible to fully assess. None had been designed as a formal validation study (most used simple tests of correlation). Only one validation study (comparing a 1-min sit-to-stand test [1MSTST] with reference to the 6-min walk test [6MWT] in 107 patients with interstitial lung disease) contained sufficient raw data for us to calculate the sensitivity (88%), specificity (81%) and positive and negative predictive value (79% and 89% respectively) of the 1MSTST. The other 4 empirical studies included two predictive studies on patients with Covid-19, and two on HIV-positive patients with suspected pneumocystis pneumonia. We found no studies on the 40-step walk test (a less demanding test that is widely used in clinical practice to assess Covid-19 patients). Heterogeneity of study design precluded meta-analysis. DISCUSSION: Exertional desaturation tests have not yet been validated in patients with (or suspected of having) Covid-19. A stronger evidence base exists for the diagnostic accuracy of the 1MSTST in chronic long-term pulmonary disease; the relative intensity of this test may raise safety concerns in remote consultations or unstable patients. The less strenuous 40-step walk test should be urgently evaluated. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13643-021-01620-w.
format Online
Article
Text
id pubmed-7961172
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-79611722021-03-16 Direct and indirect evidence of efficacy and safety of rapid exercise tests for exertional desaturation in Covid-19: a rapid systematic review Kalin, Asli Javid, Babak Knight, Matthew Inada-Kim, Matt Greenhalgh, Trisha Syst Rev Research BACKGROUND: Even when resting pulse oximetry is normal in the patient with acute Covid-19, hypoxia can manifest on exertion. We summarise the literature on the performance of different rapid tests for exertional desaturation and draw on this evidence base to provide guidance in the context of acute Covid-19. MAIN RESEARCH QUESTIONS: 1. What exercise tests have been used to assess exertional hypoxia at home or in an ambulatory setting in the context of Covid-19 and to what extent have they been validated? 2. What exercise tests have been used to assess exertional hypoxia in other lung conditions, to what extent have they been validated and what is the applicability of these studies to acute Covid-19? METHOD: AMED, CINAHL, EMBASE MEDLINE, Cochrane and PubMed using LitCovid, Scholar and Google databases were searched to September 2020. Studies where participants had Covid-19 or another lung disease and underwent any form of exercise test which was compared to a reference standard were eligible. Risk of bias was assessed using QUADAS 2. A protocol for the review was published on the Medrxiv database. RESULTS: Of 47 relevant papers, 15 were empirical studies, of which 11 described an attempt to validate one or more exercise desaturation tests in lung diseases other than Covid-19. In all but one of these, methodological quality was poor or impossible to fully assess. None had been designed as a formal validation study (most used simple tests of correlation). Only one validation study (comparing a 1-min sit-to-stand test [1MSTST] with reference to the 6-min walk test [6MWT] in 107 patients with interstitial lung disease) contained sufficient raw data for us to calculate the sensitivity (88%), specificity (81%) and positive and negative predictive value (79% and 89% respectively) of the 1MSTST. The other 4 empirical studies included two predictive studies on patients with Covid-19, and two on HIV-positive patients with suspected pneumocystis pneumonia. We found no studies on the 40-step walk test (a less demanding test that is widely used in clinical practice to assess Covid-19 patients). Heterogeneity of study design precluded meta-analysis. DISCUSSION: Exertional desaturation tests have not yet been validated in patients with (or suspected of having) Covid-19. A stronger evidence base exists for the diagnostic accuracy of the 1MSTST in chronic long-term pulmonary disease; the relative intensity of this test may raise safety concerns in remote consultations or unstable patients. The less strenuous 40-step walk test should be urgently evaluated. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13643-021-01620-w. BioMed Central 2021-03-16 /pmc/articles/PMC7961172/ /pubmed/33726854 http://dx.doi.org/10.1186/s13643-021-01620-w Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Kalin, Asli
Javid, Babak
Knight, Matthew
Inada-Kim, Matt
Greenhalgh, Trisha
Direct and indirect evidence of efficacy and safety of rapid exercise tests for exertional desaturation in Covid-19: a rapid systematic review
title Direct and indirect evidence of efficacy and safety of rapid exercise tests for exertional desaturation in Covid-19: a rapid systematic review
title_full Direct and indirect evidence of efficacy and safety of rapid exercise tests for exertional desaturation in Covid-19: a rapid systematic review
title_fullStr Direct and indirect evidence of efficacy and safety of rapid exercise tests for exertional desaturation in Covid-19: a rapid systematic review
title_full_unstemmed Direct and indirect evidence of efficacy and safety of rapid exercise tests for exertional desaturation in Covid-19: a rapid systematic review
title_short Direct and indirect evidence of efficacy and safety of rapid exercise tests for exertional desaturation in Covid-19: a rapid systematic review
title_sort direct and indirect evidence of efficacy and safety of rapid exercise tests for exertional desaturation in covid-19: a rapid systematic review
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7961172/
https://www.ncbi.nlm.nih.gov/pubmed/33726854
http://dx.doi.org/10.1186/s13643-021-01620-w
work_keys_str_mv AT kalinasli directandindirectevidenceofefficacyandsafetyofrapidexercisetestsforexertionaldesaturationincovid19arapidsystematicreview
AT javidbabak directandindirectevidenceofefficacyandsafetyofrapidexercisetestsforexertionaldesaturationincovid19arapidsystematicreview
AT knightmatthew directandindirectevidenceofefficacyandsafetyofrapidexercisetestsforexertionaldesaturationincovid19arapidsystematicreview
AT inadakimmatt directandindirectevidenceofefficacyandsafetyofrapidexercisetestsforexertionaldesaturationincovid19arapidsystematicreview
AT greenhalghtrisha directandindirectevidenceofefficacyandsafetyofrapidexercisetestsforexertionaldesaturationincovid19arapidsystematicreview