Cargando…

A Cost-Effective Inertial Measurement System for Tracking Movement and Triggering Kinesthetic Feedback in Lower-Limb Prosthesis Users

Advances in lower-limb prosthetic technologies have facilitated the restoration of ambulation; however, users of such technologies still experience reduced balance control, also due to the absence of proprioceptive feedback. Recent efforts have demonstrated the ability to restore kinesthetic feedbac...

Descripción completa

Detalles Bibliográficos
Autores principales: Keri, McNiel-Inyani, Shehata, Ahmed W., Marasco, Paul D., Hebert, Jacqueline S., Vette, Albert H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7961441/
https://www.ncbi.nlm.nih.gov/pubmed/33800790
http://dx.doi.org/10.3390/s21051844
_version_ 1783665261551812608
author Keri, McNiel-Inyani
Shehata, Ahmed W.
Marasco, Paul D.
Hebert, Jacqueline S.
Vette, Albert H.
author_facet Keri, McNiel-Inyani
Shehata, Ahmed W.
Marasco, Paul D.
Hebert, Jacqueline S.
Vette, Albert H.
author_sort Keri, McNiel-Inyani
collection PubMed
description Advances in lower-limb prosthetic technologies have facilitated the restoration of ambulation; however, users of such technologies still experience reduced balance control, also due to the absence of proprioceptive feedback. Recent efforts have demonstrated the ability to restore kinesthetic feedback in upper-limb prosthesis applications; however, technical solutions to trigger the required muscle vibration and provide automated feedback have not been explored for lower-limb prostheses. The study’s first objective was therefore to develop a feedback system capable of tracking lower-limb movement and automatically triggering a muscle vibrator to induce the kinesthetic illusion. The second objective was to investigate the developed system’s ability to provide kinesthetic feedback in a case participant. A low-cost, wireless feedback system, incorporating two inertial measurement units to trigger a muscle vibrator, was developed and tested in an individual with limb loss above the knee. Our system had a maximum communication delay of 50 ms and showed good tracking of Gaussian and sinusoidal movement profiles for velocities below 180 degrees per second (error < 8 degrees), mimicking stepping and walking, respectively. We demonstrated in the case participant that the developed feedback system can successfully elicit the kinesthetic illusion. Our work contributes to the integration of sensory feedback in lower-limb prostheses, to increase their use and functionality.
format Online
Article
Text
id pubmed-7961441
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79614412021-03-17 A Cost-Effective Inertial Measurement System for Tracking Movement and Triggering Kinesthetic Feedback in Lower-Limb Prosthesis Users Keri, McNiel-Inyani Shehata, Ahmed W. Marasco, Paul D. Hebert, Jacqueline S. Vette, Albert H. Sensors (Basel) Article Advances in lower-limb prosthetic technologies have facilitated the restoration of ambulation; however, users of such technologies still experience reduced balance control, also due to the absence of proprioceptive feedback. Recent efforts have demonstrated the ability to restore kinesthetic feedback in upper-limb prosthesis applications; however, technical solutions to trigger the required muscle vibration and provide automated feedback have not been explored for lower-limb prostheses. The study’s first objective was therefore to develop a feedback system capable of tracking lower-limb movement and automatically triggering a muscle vibrator to induce the kinesthetic illusion. The second objective was to investigate the developed system’s ability to provide kinesthetic feedback in a case participant. A low-cost, wireless feedback system, incorporating two inertial measurement units to trigger a muscle vibrator, was developed and tested in an individual with limb loss above the knee. Our system had a maximum communication delay of 50 ms and showed good tracking of Gaussian and sinusoidal movement profiles for velocities below 180 degrees per second (error < 8 degrees), mimicking stepping and walking, respectively. We demonstrated in the case participant that the developed feedback system can successfully elicit the kinesthetic illusion. Our work contributes to the integration of sensory feedback in lower-limb prostheses, to increase their use and functionality. MDPI 2021-03-06 /pmc/articles/PMC7961441/ /pubmed/33800790 http://dx.doi.org/10.3390/s21051844 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Keri, McNiel-Inyani
Shehata, Ahmed W.
Marasco, Paul D.
Hebert, Jacqueline S.
Vette, Albert H.
A Cost-Effective Inertial Measurement System for Tracking Movement and Triggering Kinesthetic Feedback in Lower-Limb Prosthesis Users
title A Cost-Effective Inertial Measurement System for Tracking Movement and Triggering Kinesthetic Feedback in Lower-Limb Prosthesis Users
title_full A Cost-Effective Inertial Measurement System for Tracking Movement and Triggering Kinesthetic Feedback in Lower-Limb Prosthesis Users
title_fullStr A Cost-Effective Inertial Measurement System for Tracking Movement and Triggering Kinesthetic Feedback in Lower-Limb Prosthesis Users
title_full_unstemmed A Cost-Effective Inertial Measurement System for Tracking Movement and Triggering Kinesthetic Feedback in Lower-Limb Prosthesis Users
title_short A Cost-Effective Inertial Measurement System for Tracking Movement and Triggering Kinesthetic Feedback in Lower-Limb Prosthesis Users
title_sort cost-effective inertial measurement system for tracking movement and triggering kinesthetic feedback in lower-limb prosthesis users
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7961441/
https://www.ncbi.nlm.nih.gov/pubmed/33800790
http://dx.doi.org/10.3390/s21051844
work_keys_str_mv AT kerimcnielinyani acosteffectiveinertialmeasurementsystemfortrackingmovementandtriggeringkinestheticfeedbackinlowerlimbprosthesisusers
AT shehataahmedw acosteffectiveinertialmeasurementsystemfortrackingmovementandtriggeringkinestheticfeedbackinlowerlimbprosthesisusers
AT marascopauld acosteffectiveinertialmeasurementsystemfortrackingmovementandtriggeringkinestheticfeedbackinlowerlimbprosthesisusers
AT hebertjacquelines acosteffectiveinertialmeasurementsystemfortrackingmovementandtriggeringkinestheticfeedbackinlowerlimbprosthesisusers
AT vettealberth acosteffectiveinertialmeasurementsystemfortrackingmovementandtriggeringkinestheticfeedbackinlowerlimbprosthesisusers
AT kerimcnielinyani costeffectiveinertialmeasurementsystemfortrackingmovementandtriggeringkinestheticfeedbackinlowerlimbprosthesisusers
AT shehataahmedw costeffectiveinertialmeasurementsystemfortrackingmovementandtriggeringkinestheticfeedbackinlowerlimbprosthesisusers
AT marascopauld costeffectiveinertialmeasurementsystemfortrackingmovementandtriggeringkinestheticfeedbackinlowerlimbprosthesisusers
AT hebertjacquelines costeffectiveinertialmeasurementsystemfortrackingmovementandtriggeringkinestheticfeedbackinlowerlimbprosthesisusers
AT vettealberth costeffectiveinertialmeasurementsystemfortrackingmovementandtriggeringkinestheticfeedbackinlowerlimbprosthesisusers