Cargando…
Grating Spectrometry and Spatial Heterodyne Fourier Transform Spectrometry: Comparative Noise Analysis for Raman Measurements
The desire for portable Raman spectrometers is continuously driving the development of novel spectrometer architectures where miniaturisation can be achieved without the penalty of a poorer detection performance. Spatial heterodyne spectrometers are emerging as potential candidates for challenging t...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7961646/ https://www.ncbi.nlm.nih.gov/pubmed/33044086 http://dx.doi.org/10.1177/0003702820957311 |
_version_ | 1783665306490634240 |
---|---|
author | Ciaffoni, Luca Matousek, Pavel Parker, William McCormack, Elin A. Mortimer, Hugh |
author_facet | Ciaffoni, Luca Matousek, Pavel Parker, William McCormack, Elin A. Mortimer, Hugh |
author_sort | Ciaffoni, Luca |
collection | PubMed |
description | The desire for portable Raman spectrometers is continuously driving the development of novel spectrometer architectures where miniaturisation can be achieved without the penalty of a poorer detection performance. Spatial heterodyne spectrometers are emerging as potential candidates for challenging the dominance of traditional grating spectrometers, thanks to their larger etendue and greater potential for miniaturisation. This paper provides a generic analytical model for estimating and comparing the detection performance of Raman spectrometers based on grating spectrometer and spatial heterodyne spectrometer designs by deriving the analytical expressions for the performance estimator (signal-to-noise ratio, SNR) for both types of spectrometers. The analysis shows that, depending on the spectral characteristics of the Raman light and on the values of some instrument-specific parameters, the ratio of the SNR estimates for the two spectrometers ([Formula: see text]) can vary as much as by two orders of magnitude. Limit cases of these equations are presented for a subset of spectral regimes which are of practical importance in real-life applications of Raman spectroscopy. In particular, under the experimental conditions where the background signal is comparable or larger than the target Raman line and shot noise is the dominant noise contribution, the value of [Formula: see text] is, to a first order of approximation, dependent solely on the relative values of each spectrometer’s etendue and on the number of row pixels in the detector array. For typical values of the key instrument-specific parameters (e.g., etendue, number of pixels, spectral bandwidth), the analysis shows that spatial heterodyne spectrometer-based Raman spectrometers have the potential to compete with compact grating spectrometer designs for delivering in a much smaller footprint (10–30 times) levels of detection performance that are approximately only five to ten times poorer. |
format | Online Article Text |
id | pubmed-7961646 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-79616462021-03-30 Grating Spectrometry and Spatial Heterodyne Fourier Transform Spectrometry: Comparative Noise Analysis for Raman Measurements Ciaffoni, Luca Matousek, Pavel Parker, William McCormack, Elin A. Mortimer, Hugh Appl Spectrosc Articles The desire for portable Raman spectrometers is continuously driving the development of novel spectrometer architectures where miniaturisation can be achieved without the penalty of a poorer detection performance. Spatial heterodyne spectrometers are emerging as potential candidates for challenging the dominance of traditional grating spectrometers, thanks to their larger etendue and greater potential for miniaturisation. This paper provides a generic analytical model for estimating and comparing the detection performance of Raman spectrometers based on grating spectrometer and spatial heterodyne spectrometer designs by deriving the analytical expressions for the performance estimator (signal-to-noise ratio, SNR) for both types of spectrometers. The analysis shows that, depending on the spectral characteristics of the Raman light and on the values of some instrument-specific parameters, the ratio of the SNR estimates for the two spectrometers ([Formula: see text]) can vary as much as by two orders of magnitude. Limit cases of these equations are presented for a subset of spectral regimes which are of practical importance in real-life applications of Raman spectroscopy. In particular, under the experimental conditions where the background signal is comparable or larger than the target Raman line and shot noise is the dominant noise contribution, the value of [Formula: see text] is, to a first order of approximation, dependent solely on the relative values of each spectrometer’s etendue and on the number of row pixels in the detector array. For typical values of the key instrument-specific parameters (e.g., etendue, number of pixels, spectral bandwidth), the analysis shows that spatial heterodyne spectrometer-based Raman spectrometers have the potential to compete with compact grating spectrometer designs for delivering in a much smaller footprint (10–30 times) levels of detection performance that are approximately only five to ten times poorer. SAGE Publications 2020-10-12 2021-03 /pmc/articles/PMC7961646/ /pubmed/33044086 http://dx.doi.org/10.1177/0003702820957311 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Articles Ciaffoni, Luca Matousek, Pavel Parker, William McCormack, Elin A. Mortimer, Hugh Grating Spectrometry and Spatial Heterodyne Fourier Transform Spectrometry: Comparative Noise Analysis for Raman Measurements |
title | Grating Spectrometry and Spatial Heterodyne Fourier Transform Spectrometry: Comparative Noise Analysis for Raman Measurements |
title_full | Grating Spectrometry and Spatial Heterodyne Fourier Transform Spectrometry: Comparative Noise Analysis for Raman Measurements |
title_fullStr | Grating Spectrometry and Spatial Heterodyne Fourier Transform Spectrometry: Comparative Noise Analysis for Raman Measurements |
title_full_unstemmed | Grating Spectrometry and Spatial Heterodyne Fourier Transform Spectrometry: Comparative Noise Analysis for Raman Measurements |
title_short | Grating Spectrometry and Spatial Heterodyne Fourier Transform Spectrometry: Comparative Noise Analysis for Raman Measurements |
title_sort | grating spectrometry and spatial heterodyne fourier transform spectrometry: comparative noise analysis for raman measurements |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7961646/ https://www.ncbi.nlm.nih.gov/pubmed/33044086 http://dx.doi.org/10.1177/0003702820957311 |
work_keys_str_mv | AT ciaffoniluca gratingspectrometryandspatialheterodynefouriertransformspectrometrycomparativenoiseanalysisforramanmeasurements AT matousekpavel gratingspectrometryandspatialheterodynefouriertransformspectrometrycomparativenoiseanalysisforramanmeasurements AT parkerwilliam gratingspectrometryandspatialheterodynefouriertransformspectrometrycomparativenoiseanalysisforramanmeasurements AT mccormackelina gratingspectrometryandspatialheterodynefouriertransformspectrometrycomparativenoiseanalysisforramanmeasurements AT mortimerhugh gratingspectrometryandspatialheterodynefouriertransformspectrometrycomparativenoiseanalysisforramanmeasurements |