Cargando…

Modeling, Fabrication and Integration of Wearable Smart Sensors in a Monitoring Platform for Diabetic Patients

The monitoring of some parameters, such as pressure loads, temperature, and glucose level in sweat on the plantar surface, is one of the most promising approaches for evaluating the health state of the diabetic foot and for preventing the onset of inflammatory events later degenerating in ulcerative...

Descripción completa

Detalles Bibliográficos
Autores principales: De Pascali, Chiara, Francioso, Luca, Giampetruzzi, Lucia, Rescio, Gabriele, Signore, Maria Assunta, Leone, Alessandro, Siciliano, Pietro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7962045/
https://www.ncbi.nlm.nih.gov/pubmed/33800949
http://dx.doi.org/10.3390/s21051847
_version_ 1783665392333357056
author De Pascali, Chiara
Francioso, Luca
Giampetruzzi, Lucia
Rescio, Gabriele
Signore, Maria Assunta
Leone, Alessandro
Siciliano, Pietro
author_facet De Pascali, Chiara
Francioso, Luca
Giampetruzzi, Lucia
Rescio, Gabriele
Signore, Maria Assunta
Leone, Alessandro
Siciliano, Pietro
author_sort De Pascali, Chiara
collection PubMed
description The monitoring of some parameters, such as pressure loads, temperature, and glucose level in sweat on the plantar surface, is one of the most promising approaches for evaluating the health state of the diabetic foot and for preventing the onset of inflammatory events later degenerating in ulcerative lesions. This work presents the results of sensors microfabrication, experimental characterization and FEA-based thermal analysis of a 3D foot-insole model, aimed to advance in the development of a fully custom smart multisensory hardware–software monitoring platform for the diabetic foot. In this system, the simultaneous detection of temperature-, pressure- and sweat-based glucose level by means of full custom microfabricated sensors distributed on eight reading points of a smart insole will be possible, and the unit for data acquisition and wireless transmission will be fully integrated into the platform. Finite element analysis simulations, based on an accurate bioheat transfer model of the metabolic response of the foot tissue, demonstrated that subcutaneous inflamed lesions located up to the muscle layer, and ischemic damage located not below the reticular/fat layer, can be successfully detected. The microfabrication processes and preliminary results of functional characterization of flexible piezoelectric pressure sensors and glucose sensors are presented. Full custom pressure sensors generate an electric charge in the range 0–20 pC, proportional to the applied load in the range 0–4 N, with a figure of merit of 4.7 ± 1 GPa. The disposable glucose sensors exhibit a 0–6 mM (0–108 mg/dL) glucose concentration optimized linear response (for sweat-sensing), with a LOD of 3.27 µM (0.058 mg/dL) and a sensitivity of 21 µA/mM cm(2) in the PBS solution. The technical prerequisites and experimental sensing performances were assessed, as preliminary step before future integration into a second prototype, based on a full custom smart insole with enhanced sensing functionalities.
format Online
Article
Text
id pubmed-7962045
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79620452021-03-17 Modeling, Fabrication and Integration of Wearable Smart Sensors in a Monitoring Platform for Diabetic Patients De Pascali, Chiara Francioso, Luca Giampetruzzi, Lucia Rescio, Gabriele Signore, Maria Assunta Leone, Alessandro Siciliano, Pietro Sensors (Basel) Article The monitoring of some parameters, such as pressure loads, temperature, and glucose level in sweat on the plantar surface, is one of the most promising approaches for evaluating the health state of the diabetic foot and for preventing the onset of inflammatory events later degenerating in ulcerative lesions. This work presents the results of sensors microfabrication, experimental characterization and FEA-based thermal analysis of a 3D foot-insole model, aimed to advance in the development of a fully custom smart multisensory hardware–software monitoring platform for the diabetic foot. In this system, the simultaneous detection of temperature-, pressure- and sweat-based glucose level by means of full custom microfabricated sensors distributed on eight reading points of a smart insole will be possible, and the unit for data acquisition and wireless transmission will be fully integrated into the platform. Finite element analysis simulations, based on an accurate bioheat transfer model of the metabolic response of the foot tissue, demonstrated that subcutaneous inflamed lesions located up to the muscle layer, and ischemic damage located not below the reticular/fat layer, can be successfully detected. The microfabrication processes and preliminary results of functional characterization of flexible piezoelectric pressure sensors and glucose sensors are presented. Full custom pressure sensors generate an electric charge in the range 0–20 pC, proportional to the applied load in the range 0–4 N, with a figure of merit of 4.7 ± 1 GPa. The disposable glucose sensors exhibit a 0–6 mM (0–108 mg/dL) glucose concentration optimized linear response (for sweat-sensing), with a LOD of 3.27 µM (0.058 mg/dL) and a sensitivity of 21 µA/mM cm(2) in the PBS solution. The technical prerequisites and experimental sensing performances were assessed, as preliminary step before future integration into a second prototype, based on a full custom smart insole with enhanced sensing functionalities. MDPI 2021-03-06 /pmc/articles/PMC7962045/ /pubmed/33800949 http://dx.doi.org/10.3390/s21051847 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
De Pascali, Chiara
Francioso, Luca
Giampetruzzi, Lucia
Rescio, Gabriele
Signore, Maria Assunta
Leone, Alessandro
Siciliano, Pietro
Modeling, Fabrication and Integration of Wearable Smart Sensors in a Monitoring Platform for Diabetic Patients
title Modeling, Fabrication and Integration of Wearable Smart Sensors in a Monitoring Platform for Diabetic Patients
title_full Modeling, Fabrication and Integration of Wearable Smart Sensors in a Monitoring Platform for Diabetic Patients
title_fullStr Modeling, Fabrication and Integration of Wearable Smart Sensors in a Monitoring Platform for Diabetic Patients
title_full_unstemmed Modeling, Fabrication and Integration of Wearable Smart Sensors in a Monitoring Platform for Diabetic Patients
title_short Modeling, Fabrication and Integration of Wearable Smart Sensors in a Monitoring Platform for Diabetic Patients
title_sort modeling, fabrication and integration of wearable smart sensors in a monitoring platform for diabetic patients
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7962045/
https://www.ncbi.nlm.nih.gov/pubmed/33800949
http://dx.doi.org/10.3390/s21051847
work_keys_str_mv AT depascalichiara modelingfabricationandintegrationofwearablesmartsensorsinamonitoringplatformfordiabeticpatients
AT franciosoluca modelingfabricationandintegrationofwearablesmartsensorsinamonitoringplatformfordiabeticpatients
AT giampetruzzilucia modelingfabricationandintegrationofwearablesmartsensorsinamonitoringplatformfordiabeticpatients
AT resciogabriele modelingfabricationandintegrationofwearablesmartsensorsinamonitoringplatformfordiabeticpatients
AT signoremariaassunta modelingfabricationandintegrationofwearablesmartsensorsinamonitoringplatformfordiabeticpatients
AT leonealessandro modelingfabricationandintegrationofwearablesmartsensorsinamonitoringplatformfordiabeticpatients
AT sicilianopietro modelingfabricationandintegrationofwearablesmartsensorsinamonitoringplatformfordiabeticpatients