Cargando…

Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study

BACKGROUND: Due to a high incidence of cardiac implantable electronic device-associated infective endocarditis (CIED-IE) in cases of Staphylococcus aureus bacteremia (SAB) and high mortality with conservative management, guidelines advocate device removal in all subjects with SAB. We aimed to invest...

Descripción completa

Detalles Bibliográficos
Autores principales: Pichtchoulin, Sara, Selmeryd, Ingrid, Freyhult, Elisabeth, Hedberg, Pär, Selmeryd, Jonas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Open Academia 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7962178/
https://www.ncbi.nlm.nih.gov/pubmed/33777330
http://dx.doi.org/10.48101/ujms.v126.5653
_version_ 1783665417994108928
author Pichtchoulin, Sara
Selmeryd, Ingrid
Freyhult, Elisabeth
Hedberg, Pär
Selmeryd, Jonas
author_facet Pichtchoulin, Sara
Selmeryd, Ingrid
Freyhult, Elisabeth
Hedberg, Pär
Selmeryd, Jonas
author_sort Pichtchoulin, Sara
collection PubMed
description BACKGROUND: Due to a high incidence of cardiac implantable electronic device-associated infective endocarditis (CIED-IE) in cases of Staphylococcus aureus bacteremia (SAB) and high mortality with conservative management, guidelines advocate device removal in all subjects with SAB. We aimed to investigate the clinical course of SAB in patients with a CIED (SAB+CIED) in a Swedish county hospital setting and relate it to guideline recommendations. METHODS: All CIED carriers with SAB, excluding clinical pocket infections, in the County of Västmanland during 2010–2017 were reviewed retrospectively. RESULTS: There were 61 cases of SAB+CIED during the study period, and CIED-IE was diagnosed in 13/61 (21%) cases. In-hospital death occurred in 19/61 (31%) cases, 34/61 (56%) cases were discharged with CIED device retained, and 8/61 (13%) cases were discharged after device removal. Subjects dying during hospitalization were elderly and diseased. No events was seen if the CIED was removed. Among four discharged cases with conservatively managed CIED-IE one relapse occured. Among 30 cases discharged with retained CIED and no evidence of IE, 22/30 (73%) cases had an uneventful follow-up, whereas adverse events secondary to overlooked CIED-IE were likely in 1/30 (3%) cases and could not be definitely excluded in additionally 4/30 (13%) cases. CONCLUSIONS: During the study period, management became more active and prognosis improved. The heterogeneity within the population of SAB+CIED suggests that a management strategy based on an individual risk/benefit analysis could be an alternative to mandatory device removal.
format Online
Article
Text
id pubmed-7962178
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Open Academia
record_format MEDLINE/PubMed
spelling pubmed-79621782021-03-25 Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study Pichtchoulin, Sara Selmeryd, Ingrid Freyhult, Elisabeth Hedberg, Pär Selmeryd, Jonas Ups J Med Sci Original Article BACKGROUND: Due to a high incidence of cardiac implantable electronic device-associated infective endocarditis (CIED-IE) in cases of Staphylococcus aureus bacteremia (SAB) and high mortality with conservative management, guidelines advocate device removal in all subjects with SAB. We aimed to investigate the clinical course of SAB in patients with a CIED (SAB+CIED) in a Swedish county hospital setting and relate it to guideline recommendations. METHODS: All CIED carriers with SAB, excluding clinical pocket infections, in the County of Västmanland during 2010–2017 were reviewed retrospectively. RESULTS: There were 61 cases of SAB+CIED during the study period, and CIED-IE was diagnosed in 13/61 (21%) cases. In-hospital death occurred in 19/61 (31%) cases, 34/61 (56%) cases were discharged with CIED device retained, and 8/61 (13%) cases were discharged after device removal. Subjects dying during hospitalization were elderly and diseased. No events was seen if the CIED was removed. Among four discharged cases with conservatively managed CIED-IE one relapse occured. Among 30 cases discharged with retained CIED and no evidence of IE, 22/30 (73%) cases had an uneventful follow-up, whereas adverse events secondary to overlooked CIED-IE were likely in 1/30 (3%) cases and could not be definitely excluded in additionally 4/30 (13%) cases. CONCLUSIONS: During the study period, management became more active and prognosis improved. The heterogeneity within the population of SAB+CIED suggests that a management strategy based on an individual risk/benefit analysis could be an alternative to mandatory device removal. Open Academia 2021-03-05 /pmc/articles/PMC7962178/ /pubmed/33777330 http://dx.doi.org/10.48101/ujms.v126.5653 Text en © 2021 The Author(s). Published by Upsala Medical Society. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Pichtchoulin, Sara
Selmeryd, Ingrid
Freyhult, Elisabeth
Hedberg, Pär
Selmeryd, Jonas
Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study
title Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study
title_full Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study
title_fullStr Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study
title_full_unstemmed Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study
title_short Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study
title_sort staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7962178/
https://www.ncbi.nlm.nih.gov/pubmed/33777330
http://dx.doi.org/10.48101/ujms.v126.5653
work_keys_str_mv AT pichtchoulinsara staphylococcusaureusbacteremiaandcardiacimplantableelectronicdevicesinacountyhospitalsettingapopulationbasedretrospectivecohortstudy
AT selmerydingrid staphylococcusaureusbacteremiaandcardiacimplantableelectronicdevicesinacountyhospitalsettingapopulationbasedretrospectivecohortstudy
AT freyhultelisabeth staphylococcusaureusbacteremiaandcardiacimplantableelectronicdevicesinacountyhospitalsettingapopulationbasedretrospectivecohortstudy
AT hedbergpar staphylococcusaureusbacteremiaandcardiacimplantableelectronicdevicesinacountyhospitalsettingapopulationbasedretrospectivecohortstudy
AT selmerydjonas staphylococcusaureusbacteremiaandcardiacimplantableelectronicdevicesinacountyhospitalsettingapopulationbasedretrospectivecohortstudy