Cargando…
Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study
BACKGROUND: Due to a high incidence of cardiac implantable electronic device-associated infective endocarditis (CIED-IE) in cases of Staphylococcus aureus bacteremia (SAB) and high mortality with conservative management, guidelines advocate device removal in all subjects with SAB. We aimed to invest...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Open Academia
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7962178/ https://www.ncbi.nlm.nih.gov/pubmed/33777330 http://dx.doi.org/10.48101/ujms.v126.5653 |
_version_ | 1783665417994108928 |
---|---|
author | Pichtchoulin, Sara Selmeryd, Ingrid Freyhult, Elisabeth Hedberg, Pär Selmeryd, Jonas |
author_facet | Pichtchoulin, Sara Selmeryd, Ingrid Freyhult, Elisabeth Hedberg, Pär Selmeryd, Jonas |
author_sort | Pichtchoulin, Sara |
collection | PubMed |
description | BACKGROUND: Due to a high incidence of cardiac implantable electronic device-associated infective endocarditis (CIED-IE) in cases of Staphylococcus aureus bacteremia (SAB) and high mortality with conservative management, guidelines advocate device removal in all subjects with SAB. We aimed to investigate the clinical course of SAB in patients with a CIED (SAB+CIED) in a Swedish county hospital setting and relate it to guideline recommendations. METHODS: All CIED carriers with SAB, excluding clinical pocket infections, in the County of Västmanland during 2010–2017 were reviewed retrospectively. RESULTS: There were 61 cases of SAB+CIED during the study period, and CIED-IE was diagnosed in 13/61 (21%) cases. In-hospital death occurred in 19/61 (31%) cases, 34/61 (56%) cases were discharged with CIED device retained, and 8/61 (13%) cases were discharged after device removal. Subjects dying during hospitalization were elderly and diseased. No events was seen if the CIED was removed. Among four discharged cases with conservatively managed CIED-IE one relapse occured. Among 30 cases discharged with retained CIED and no evidence of IE, 22/30 (73%) cases had an uneventful follow-up, whereas adverse events secondary to overlooked CIED-IE were likely in 1/30 (3%) cases and could not be definitely excluded in additionally 4/30 (13%) cases. CONCLUSIONS: During the study period, management became more active and prognosis improved. The heterogeneity within the population of SAB+CIED suggests that a management strategy based on an individual risk/benefit analysis could be an alternative to mandatory device removal. |
format | Online Article Text |
id | pubmed-7962178 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Open Academia |
record_format | MEDLINE/PubMed |
spelling | pubmed-79621782021-03-25 Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study Pichtchoulin, Sara Selmeryd, Ingrid Freyhult, Elisabeth Hedberg, Pär Selmeryd, Jonas Ups J Med Sci Original Article BACKGROUND: Due to a high incidence of cardiac implantable electronic device-associated infective endocarditis (CIED-IE) in cases of Staphylococcus aureus bacteremia (SAB) and high mortality with conservative management, guidelines advocate device removal in all subjects with SAB. We aimed to investigate the clinical course of SAB in patients with a CIED (SAB+CIED) in a Swedish county hospital setting and relate it to guideline recommendations. METHODS: All CIED carriers with SAB, excluding clinical pocket infections, in the County of Västmanland during 2010–2017 were reviewed retrospectively. RESULTS: There were 61 cases of SAB+CIED during the study period, and CIED-IE was diagnosed in 13/61 (21%) cases. In-hospital death occurred in 19/61 (31%) cases, 34/61 (56%) cases were discharged with CIED device retained, and 8/61 (13%) cases were discharged after device removal. Subjects dying during hospitalization were elderly and diseased. No events was seen if the CIED was removed. Among four discharged cases with conservatively managed CIED-IE one relapse occured. Among 30 cases discharged with retained CIED and no evidence of IE, 22/30 (73%) cases had an uneventful follow-up, whereas adverse events secondary to overlooked CIED-IE were likely in 1/30 (3%) cases and could not be definitely excluded in additionally 4/30 (13%) cases. CONCLUSIONS: During the study period, management became more active and prognosis improved. The heterogeneity within the population of SAB+CIED suggests that a management strategy based on an individual risk/benefit analysis could be an alternative to mandatory device removal. Open Academia 2021-03-05 /pmc/articles/PMC7962178/ /pubmed/33777330 http://dx.doi.org/10.48101/ujms.v126.5653 Text en © 2021 The Author(s). Published by Upsala Medical Society. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Pichtchoulin, Sara Selmeryd, Ingrid Freyhult, Elisabeth Hedberg, Pär Selmeryd, Jonas Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study |
title | Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study |
title_full | Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study |
title_fullStr | Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study |
title_full_unstemmed | Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study |
title_short | Staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study |
title_sort | staphylococcus aureus bacteremia and cardiac implantable electronic devices in a county hospital setting: a population-based retrospective cohort study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7962178/ https://www.ncbi.nlm.nih.gov/pubmed/33777330 http://dx.doi.org/10.48101/ujms.v126.5653 |
work_keys_str_mv | AT pichtchoulinsara staphylococcusaureusbacteremiaandcardiacimplantableelectronicdevicesinacountyhospitalsettingapopulationbasedretrospectivecohortstudy AT selmerydingrid staphylococcusaureusbacteremiaandcardiacimplantableelectronicdevicesinacountyhospitalsettingapopulationbasedretrospectivecohortstudy AT freyhultelisabeth staphylococcusaureusbacteremiaandcardiacimplantableelectronicdevicesinacountyhospitalsettingapopulationbasedretrospectivecohortstudy AT hedbergpar staphylococcusaureusbacteremiaandcardiacimplantableelectronicdevicesinacountyhospitalsettingapopulationbasedretrospectivecohortstudy AT selmerydjonas staphylococcusaureusbacteremiaandcardiacimplantableelectronicdevicesinacountyhospitalsettingapopulationbasedretrospectivecohortstudy |