Cargando…

The Variability of Pelvic Obliquity Measurements in Patients with Neuromuscular Scoliosis

Pelvic obliquity (PO), or pelvic alignment in the coronal plane, is an important radiographic parameter to indicate fusion levels and judge success of scoliosis correction in patients with neuromuscular scoliosis. There are multiple commonly used techniques to measure PO that have good to excellent...

Descripción completa

Detalles Bibliográficos
Autores principales: Karkenny, Alexa J., Magee, Lacey C., Landrum, Matthew R., Anari, Jason B., Spiegel, David, Baldwin, Keith
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Journal of Bone and Joint Surgery, Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7963507/
https://www.ncbi.nlm.nih.gov/pubmed/33748643
http://dx.doi.org/10.2106/JBJS.OA.20.00143
_version_ 1783665618419974144
author Karkenny, Alexa J.
Magee, Lacey C.
Landrum, Matthew R.
Anari, Jason B.
Spiegel, David
Baldwin, Keith
author_facet Karkenny, Alexa J.
Magee, Lacey C.
Landrum, Matthew R.
Anari, Jason B.
Spiegel, David
Baldwin, Keith
author_sort Karkenny, Alexa J.
collection PubMed
description Pelvic obliquity (PO), or pelvic alignment in the coronal plane, is an important radiographic parameter to indicate fusion levels and judge success of scoliosis correction in patients with neuromuscular scoliosis. There are multiple commonly used techniques to measure PO that have good to excellent interrater and intrarater reliability, but these different methods yield inconsistent values when used on the same radiograph. This study evaluates the inconsistency in the magnitude of PO measurements for patients with neuromuscular scoliosis among 5 common measurement techniques. METHODS: Radiographs of 63 patients with neuromuscular scoliosis were evaluated by 5 raters. Each rater measured PO on each radiograph using the Osebold, O’Brien, Allen and Ferguson, Lindseth, and Maloney techniques. Patients were divided into 2 cohorts based on coronal balance or imbalance. Interrater and intrarater analyses were performed using a 2-way random effects model to calculate absolute agreement. The mean difference in PO between all possible pairs of the techniques was compared using a 2-tailed t test. RESULTS: The Maloney and Osebold techniques demonstrated excellent interrater reliability, and the Maloney, Osebold, and O’Brien techniques demonstrated excellent intrarater reliability. Significant differences in PO measurement were found in 6 of the 10 comparisons for the balanced spines and 8 of the 10 comparisons for the unbalanced spines. Variability in measurement was captured by best-fit lines, which demonstrated greater dispersion between the means for the Osebold and Maloney techniques in the unbalanced spines than in the balanced spines. CONCLUSIONS: To our knowledge, this study is the first to evaluate mean differences in magnitude of PO among common measurement techniques while accounting for coronal imbalance. Although there is no gold standard for measuring PO, the Maloney and Osebold techniques are the most consistent. This study suggests that those 2 techniques can be used interchangeably when the spine is coronally balanced, but the Osebold technique becomes more inconsistent than the Maloney technique when coronal imbalance exceeds 2 cm. CLINICAL RELEVANCE: This information is relevant to surgeons using PO to plan fusion levels and striving for objective ways to judge correction intraoperatively as well as for researchers compiling PO data from multiple centers or studies.
format Online
Article
Text
id pubmed-7963507
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Journal of Bone and Joint Surgery, Inc.
record_format MEDLINE/PubMed
spelling pubmed-79635072021-03-18 The Variability of Pelvic Obliquity Measurements in Patients with Neuromuscular Scoliosis Karkenny, Alexa J. Magee, Lacey C. Landrum, Matthew R. Anari, Jason B. Spiegel, David Baldwin, Keith JB JS Open Access Scientific Articles Pelvic obliquity (PO), or pelvic alignment in the coronal plane, is an important radiographic parameter to indicate fusion levels and judge success of scoliosis correction in patients with neuromuscular scoliosis. There are multiple commonly used techniques to measure PO that have good to excellent interrater and intrarater reliability, but these different methods yield inconsistent values when used on the same radiograph. This study evaluates the inconsistency in the magnitude of PO measurements for patients with neuromuscular scoliosis among 5 common measurement techniques. METHODS: Radiographs of 63 patients with neuromuscular scoliosis were evaluated by 5 raters. Each rater measured PO on each radiograph using the Osebold, O’Brien, Allen and Ferguson, Lindseth, and Maloney techniques. Patients were divided into 2 cohorts based on coronal balance or imbalance. Interrater and intrarater analyses were performed using a 2-way random effects model to calculate absolute agreement. The mean difference in PO between all possible pairs of the techniques was compared using a 2-tailed t test. RESULTS: The Maloney and Osebold techniques demonstrated excellent interrater reliability, and the Maloney, Osebold, and O’Brien techniques demonstrated excellent intrarater reliability. Significant differences in PO measurement were found in 6 of the 10 comparisons for the balanced spines and 8 of the 10 comparisons for the unbalanced spines. Variability in measurement was captured by best-fit lines, which demonstrated greater dispersion between the means for the Osebold and Maloney techniques in the unbalanced spines than in the balanced spines. CONCLUSIONS: To our knowledge, this study is the first to evaluate mean differences in magnitude of PO among common measurement techniques while accounting for coronal imbalance. Although there is no gold standard for measuring PO, the Maloney and Osebold techniques are the most consistent. This study suggests that those 2 techniques can be used interchangeably when the spine is coronally balanced, but the Osebold technique becomes more inconsistent than the Maloney technique when coronal imbalance exceeds 2 cm. CLINICAL RELEVANCE: This information is relevant to surgeons using PO to plan fusion levels and striving for objective ways to judge correction intraoperatively as well as for researchers compiling PO data from multiple centers or studies. Journal of Bone and Joint Surgery, Inc. 2021-03-10 /pmc/articles/PMC7963507/ /pubmed/33748643 http://dx.doi.org/10.2106/JBJS.OA.20.00143 Text en Copyright © 2021 The Authors. Published by The Journal of Bone and Joint Surgery, Incorporated. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Scientific Articles
Karkenny, Alexa J.
Magee, Lacey C.
Landrum, Matthew R.
Anari, Jason B.
Spiegel, David
Baldwin, Keith
The Variability of Pelvic Obliquity Measurements in Patients with Neuromuscular Scoliosis
title The Variability of Pelvic Obliquity Measurements in Patients with Neuromuscular Scoliosis
title_full The Variability of Pelvic Obliquity Measurements in Patients with Neuromuscular Scoliosis
title_fullStr The Variability of Pelvic Obliquity Measurements in Patients with Neuromuscular Scoliosis
title_full_unstemmed The Variability of Pelvic Obliquity Measurements in Patients with Neuromuscular Scoliosis
title_short The Variability of Pelvic Obliquity Measurements in Patients with Neuromuscular Scoliosis
title_sort variability of pelvic obliquity measurements in patients with neuromuscular scoliosis
topic Scientific Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7963507/
https://www.ncbi.nlm.nih.gov/pubmed/33748643
http://dx.doi.org/10.2106/JBJS.OA.20.00143
work_keys_str_mv AT karkennyalexaj thevariabilityofpelvicobliquitymeasurementsinpatientswithneuromuscularscoliosis
AT mageelaceyc thevariabilityofpelvicobliquitymeasurementsinpatientswithneuromuscularscoliosis
AT landrummatthewr thevariabilityofpelvicobliquitymeasurementsinpatientswithneuromuscularscoliosis
AT anarijasonb thevariabilityofpelvicobliquitymeasurementsinpatientswithneuromuscularscoliosis
AT spiegeldavid thevariabilityofpelvicobliquitymeasurementsinpatientswithneuromuscularscoliosis
AT baldwinkeith thevariabilityofpelvicobliquitymeasurementsinpatientswithneuromuscularscoliosis
AT karkennyalexaj variabilityofpelvicobliquitymeasurementsinpatientswithneuromuscularscoliosis
AT mageelaceyc variabilityofpelvicobliquitymeasurementsinpatientswithneuromuscularscoliosis
AT landrummatthewr variabilityofpelvicobliquitymeasurementsinpatientswithneuromuscularscoliosis
AT anarijasonb variabilityofpelvicobliquitymeasurementsinpatientswithneuromuscularscoliosis
AT spiegeldavid variabilityofpelvicobliquitymeasurementsinpatientswithneuromuscularscoliosis
AT baldwinkeith variabilityofpelvicobliquitymeasurementsinpatientswithneuromuscularscoliosis