Cargando…

Assessing Adherence to Antihypertensive Medication by Means of Dose-Dependent Reference Plasma Concentration Ranges and Ultra-High Performance Liquid Chromatography-Ion Trap Mass Spectrometry Analysis

Poor adherence to antihypertensive drug therapy is a well-recognized problem and can be assessed by mass spectrometry-based analyses of body fluids. However, contrary statements exist whether drug quantification in blood or qualitative screening in urine is more suitable. The present pilot study aim...

Descripción completa

Detalles Bibliográficos
Autores principales: Wagmann, Lea, Vollmer, Aline C., Lauder, Lucas, Mahfoud, Felix, Meyer, Markus R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7967203/
https://www.ncbi.nlm.nih.gov/pubmed/33803489
http://dx.doi.org/10.3390/molecules26051495
_version_ 1783665825034534912
author Wagmann, Lea
Vollmer, Aline C.
Lauder, Lucas
Mahfoud, Felix
Meyer, Markus R.
author_facet Wagmann, Lea
Vollmer, Aline C.
Lauder, Lucas
Mahfoud, Felix
Meyer, Markus R.
author_sort Wagmann, Lea
collection PubMed
description Poor adherence to antihypertensive drug therapy is a well-recognized problem and can be assessed by mass spectrometry-based analyses of body fluids. However, contrary statements exist whether drug quantification in blood or qualitative screening in urine is more suitable. The present pilot study aimed to further elucidate the power of blood plasma drug concentrations for adherence monitoring by developing and validating a quantification procedure for nine antihypertensive drugs (amlodipine, bisoprolol, candesartan, canrenone, carvedilol, metoprolol, olmesartan, torasemide, and valsartan) in blood plasma using liquid–liquid extraction and an ultra-high-performance liquid chromatography-ion trap mass spectrometry analysis. The procedure should then be used for an adherence assessment and compared with the results of an established qualitative urine screening. Selectivity, carryover, matrix effect, accuracy, precision, dilution integrity, and stability were successfully validated, except for amlodipine. The applicability was demonstrated by analyzing 19 plasma samples containing 28 antihypertensive drugs and comparing the measured concentrations with calculated dose-dependent reference plasma concentration ranges. The interpretation of plasma concentrations was found to be more sophisticated and time-consuming than that of urine screening results, and adherence could not be assessed in two cases (10%) due to measured plasma concentrations below the lower limit of quantification. However, 14 out of 19 subjects were classified as adherent (75%) and three as nonadherent (15%), in contrast to 19 (100%) that were claimed to be adherent based on the results of the qualitative urine screening. Nevertheless, further data is needed to estimate whether plasma quantification is superior in terms of assessing adherence to antihypertensive medication.
format Online
Article
Text
id pubmed-7967203
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79672032021-03-18 Assessing Adherence to Antihypertensive Medication by Means of Dose-Dependent Reference Plasma Concentration Ranges and Ultra-High Performance Liquid Chromatography-Ion Trap Mass Spectrometry Analysis Wagmann, Lea Vollmer, Aline C. Lauder, Lucas Mahfoud, Felix Meyer, Markus R. Molecules Article Poor adherence to antihypertensive drug therapy is a well-recognized problem and can be assessed by mass spectrometry-based analyses of body fluids. However, contrary statements exist whether drug quantification in blood or qualitative screening in urine is more suitable. The present pilot study aimed to further elucidate the power of blood plasma drug concentrations for adherence monitoring by developing and validating a quantification procedure for nine antihypertensive drugs (amlodipine, bisoprolol, candesartan, canrenone, carvedilol, metoprolol, olmesartan, torasemide, and valsartan) in blood plasma using liquid–liquid extraction and an ultra-high-performance liquid chromatography-ion trap mass spectrometry analysis. The procedure should then be used for an adherence assessment and compared with the results of an established qualitative urine screening. Selectivity, carryover, matrix effect, accuracy, precision, dilution integrity, and stability were successfully validated, except for amlodipine. The applicability was demonstrated by analyzing 19 plasma samples containing 28 antihypertensive drugs and comparing the measured concentrations with calculated dose-dependent reference plasma concentration ranges. The interpretation of plasma concentrations was found to be more sophisticated and time-consuming than that of urine screening results, and adherence could not be assessed in two cases (10%) due to measured plasma concentrations below the lower limit of quantification. However, 14 out of 19 subjects were classified as adherent (75%) and three as nonadherent (15%), in contrast to 19 (100%) that were claimed to be adherent based on the results of the qualitative urine screening. Nevertheless, further data is needed to estimate whether plasma quantification is superior in terms of assessing adherence to antihypertensive medication. MDPI 2021-03-09 /pmc/articles/PMC7967203/ /pubmed/33803489 http://dx.doi.org/10.3390/molecules26051495 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wagmann, Lea
Vollmer, Aline C.
Lauder, Lucas
Mahfoud, Felix
Meyer, Markus R.
Assessing Adherence to Antihypertensive Medication by Means of Dose-Dependent Reference Plasma Concentration Ranges and Ultra-High Performance Liquid Chromatography-Ion Trap Mass Spectrometry Analysis
title Assessing Adherence to Antihypertensive Medication by Means of Dose-Dependent Reference Plasma Concentration Ranges and Ultra-High Performance Liquid Chromatography-Ion Trap Mass Spectrometry Analysis
title_full Assessing Adherence to Antihypertensive Medication by Means of Dose-Dependent Reference Plasma Concentration Ranges and Ultra-High Performance Liquid Chromatography-Ion Trap Mass Spectrometry Analysis
title_fullStr Assessing Adherence to Antihypertensive Medication by Means of Dose-Dependent Reference Plasma Concentration Ranges and Ultra-High Performance Liquid Chromatography-Ion Trap Mass Spectrometry Analysis
title_full_unstemmed Assessing Adherence to Antihypertensive Medication by Means of Dose-Dependent Reference Plasma Concentration Ranges and Ultra-High Performance Liquid Chromatography-Ion Trap Mass Spectrometry Analysis
title_short Assessing Adherence to Antihypertensive Medication by Means of Dose-Dependent Reference Plasma Concentration Ranges and Ultra-High Performance Liquid Chromatography-Ion Trap Mass Spectrometry Analysis
title_sort assessing adherence to antihypertensive medication by means of dose-dependent reference plasma concentration ranges and ultra-high performance liquid chromatography-ion trap mass spectrometry analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7967203/
https://www.ncbi.nlm.nih.gov/pubmed/33803489
http://dx.doi.org/10.3390/molecules26051495
work_keys_str_mv AT wagmannlea assessingadherencetoantihypertensivemedicationbymeansofdosedependentreferenceplasmaconcentrationrangesandultrahighperformanceliquidchromatographyiontrapmassspectrometryanalysis
AT vollmeralinec assessingadherencetoantihypertensivemedicationbymeansofdosedependentreferenceplasmaconcentrationrangesandultrahighperformanceliquidchromatographyiontrapmassspectrometryanalysis
AT lauderlucas assessingadherencetoantihypertensivemedicationbymeansofdosedependentreferenceplasmaconcentrationrangesandultrahighperformanceliquidchromatographyiontrapmassspectrometryanalysis
AT mahfoudfelix assessingadherencetoantihypertensivemedicationbymeansofdosedependentreferenceplasmaconcentrationrangesandultrahighperformanceliquidchromatographyiontrapmassspectrometryanalysis
AT meyermarkusr assessingadherencetoantihypertensivemedicationbymeansofdosedependentreferenceplasmaconcentrationrangesandultrahighperformanceliquidchromatographyiontrapmassspectrometryanalysis