Cargando…

Repeated rotation of a toric implantable collamer lens: A case report

INTRODUCTION: Implantable collamer lens have been used widely worldwide, and have been accepted by more and more doctors and patients due to good safety, stability, and effectiveness. However, there is still a problem of crystal rotation. The large angle rotation (over 10°) would weaken the original...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Haorun, Fu, Mengjun, Wang, Jiahao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7969312/
https://www.ncbi.nlm.nih.gov/pubmed/33725870
http://dx.doi.org/10.1097/MD.0000000000024986
_version_ 1783666219414454272
author Zhang, Haorun
Fu, Mengjun
Wang, Jiahao
author_facet Zhang, Haorun
Fu, Mengjun
Wang, Jiahao
author_sort Zhang, Haorun
collection PubMed
description INTRODUCTION: Implantable collamer lens have been used widely worldwide, and have been accepted by more and more doctors and patients due to good safety, stability, and effectiveness. However, there is still a problem of crystal rotation. The large angle rotation (over 10°) would weaken the original astigmatism correction effect and even induce irregular astigmatism, seriously affecting the visual quality of patients. Herein, we reported a case who had 2 times of crystal rotations after toric implantable collamer lens (TICL) implantation. PATIENT CONCERNS: The patient was a 38-year-old man who underwent TICL implantation for the correction of high myopic astigmatism in eyes. He presented a sudden decrease in the visual acuity (VA) of the left eye 4 months after the TICL implantation. The uncorrected visual acuity (UCVA) was 8/20 (refraction, +2.25 −5.25 × 68). DIAGNOSIS: Rotation of TICL was diagnosed. The toric marks with a rotation of 75° counter-clockwise from the original position were observed. INTERVENTIONS: The TICL was re-set to the original position, leading to the UCVA of 12/20 in the left eye (refraction, −0.00 −0.75 × 131), with the vaulting of 589 μm. Ten months after the TICL relocation, the patient again presented a sudden decrease in the VA of the left eye, with the UCVA of 2/20 (refraction, +2.25 −5.00 × 66). Again, the toric marks with a rotation of 75° counter-clockwise from the original position was observed, just at the same position as the last rotation. This time, the TICL was removed. The axis and power were recalculated, and a new TICL was implanted, with the rotation of 73° counter-clockwise from the horizontal line of the temporal side. OUTCOMES: The patient obtained a final UCVA of 12/20 in the left eye (refraction, +0.50 −0.50 × 26), which remained stable in the 6-month follow-up period, with the vaulting of 602 μm. LESSONS: Rotation is a common complication after TICL surgery. Relocation or replacement of TICL are safe and efficient ways to recover VA due to TICL rotation.
format Online
Article
Text
id pubmed-7969312
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-79693122021-03-18 Repeated rotation of a toric implantable collamer lens: A case report Zhang, Haorun Fu, Mengjun Wang, Jiahao Medicine (Baltimore) 5800 INTRODUCTION: Implantable collamer lens have been used widely worldwide, and have been accepted by more and more doctors and patients due to good safety, stability, and effectiveness. However, there is still a problem of crystal rotation. The large angle rotation (over 10°) would weaken the original astigmatism correction effect and even induce irregular astigmatism, seriously affecting the visual quality of patients. Herein, we reported a case who had 2 times of crystal rotations after toric implantable collamer lens (TICL) implantation. PATIENT CONCERNS: The patient was a 38-year-old man who underwent TICL implantation for the correction of high myopic astigmatism in eyes. He presented a sudden decrease in the visual acuity (VA) of the left eye 4 months after the TICL implantation. The uncorrected visual acuity (UCVA) was 8/20 (refraction, +2.25 −5.25 × 68). DIAGNOSIS: Rotation of TICL was diagnosed. The toric marks with a rotation of 75° counter-clockwise from the original position were observed. INTERVENTIONS: The TICL was re-set to the original position, leading to the UCVA of 12/20 in the left eye (refraction, −0.00 −0.75 × 131), with the vaulting of 589 μm. Ten months after the TICL relocation, the patient again presented a sudden decrease in the VA of the left eye, with the UCVA of 2/20 (refraction, +2.25 −5.00 × 66). Again, the toric marks with a rotation of 75° counter-clockwise from the original position was observed, just at the same position as the last rotation. This time, the TICL was removed. The axis and power were recalculated, and a new TICL was implanted, with the rotation of 73° counter-clockwise from the horizontal line of the temporal side. OUTCOMES: The patient obtained a final UCVA of 12/20 in the left eye (refraction, +0.50 −0.50 × 26), which remained stable in the 6-month follow-up period, with the vaulting of 602 μm. LESSONS: Rotation is a common complication after TICL surgery. Relocation or replacement of TICL are safe and efficient ways to recover VA due to TICL rotation. Lippincott Williams & Wilkins 2021-03-12 /pmc/articles/PMC7969312/ /pubmed/33725870 http://dx.doi.org/10.1097/MD.0000000000024986 Text en Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0
spellingShingle 5800
Zhang, Haorun
Fu, Mengjun
Wang, Jiahao
Repeated rotation of a toric implantable collamer lens: A case report
title Repeated rotation of a toric implantable collamer lens: A case report
title_full Repeated rotation of a toric implantable collamer lens: A case report
title_fullStr Repeated rotation of a toric implantable collamer lens: A case report
title_full_unstemmed Repeated rotation of a toric implantable collamer lens: A case report
title_short Repeated rotation of a toric implantable collamer lens: A case report
title_sort repeated rotation of a toric implantable collamer lens: a case report
topic 5800
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7969312/
https://www.ncbi.nlm.nih.gov/pubmed/33725870
http://dx.doi.org/10.1097/MD.0000000000024986
work_keys_str_mv AT zhanghaorun repeatedrotationofatoricimplantablecollamerlensacasereport
AT fumengjun repeatedrotationofatoricimplantablecollamerlensacasereport
AT wangjiahao repeatedrotationofatoricimplantablecollamerlensacasereport