Cargando…

Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise

Objective: To assess the inter-evaluator and intra-evaluator reliability of a software program used to extract kinematic variables by a commercially available extremity-mounted inertial measurement unit system in sound horses at the trot under soft and hard ground conditions and treadmill exercise....

Descripción completa

Detalles Bibliográficos
Autores principales: Schwarz, Julia, Vidondo, Beatriz, Maninchedda, Ugo E., Sprick, Miriam, Schöpfer, Melina C., Cruz, Antonio M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7969790/
https://www.ncbi.nlm.nih.gov/pubmed/33748204
http://dx.doi.org/10.3389/fvets.2021.595455
_version_ 1783666298911195136
author Schwarz, Julia
Vidondo, Beatriz
Maninchedda, Ugo E.
Sprick, Miriam
Schöpfer, Melina C.
Cruz, Antonio M.
author_facet Schwarz, Julia
Vidondo, Beatriz
Maninchedda, Ugo E.
Sprick, Miriam
Schöpfer, Melina C.
Cruz, Antonio M.
author_sort Schwarz, Julia
collection PubMed
description Objective: To assess the inter-evaluator and intra-evaluator reliability of a software program used to extract kinematic variables by a commercially available extremity-mounted inertial measurement unit system in sound horses at the trot under soft and hard ground conditions and treadmill exercise. Animals: Thirty adult, sound and healthy French Montagne stallions. Procedures: Data collection was performed with six IMUs strapped to the distal, metacarpal, metatarsal and tibial regions of every horse. Per surface (treadmill, soft and hard ground) 10 stallions were trotted three times. Prior to the analysis done by six evaluators (three experienced, three inexperienced) the data was blinded and copied three times. For every analysis a minimum of five strides had to be selected. To assess the intra- and inter-evaluator reliability a selection of gait variables was used to calculate intra and inter correlation coefficients (ICCs) as well as variance partitioning coefficients (VPCs). Results: All of the tested gait variables showed high levels of reliability. There was no mentionable difference considering the correlation coefficients between the intra and inter reliability as well as between the three different surfaces. VPCs showed that the factor horse is by far the most responsible for any appearing variance. The experience of the evaluator had no influence on the results. Conclusions and Clinical Relevance: The software program tested in this study has a high inter- and intra-evaluator reliability under the chosen conditions for the selected variables and acts independent of the ground situation and the experience of the evaluator. On the condition of a correct application it has the potential to become a clinically relevant and reliable gait analysis tool.
format Online
Article
Text
id pubmed-7969790
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-79697902021-03-19 Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise Schwarz, Julia Vidondo, Beatriz Maninchedda, Ugo E. Sprick, Miriam Schöpfer, Melina C. Cruz, Antonio M. Front Vet Sci Veterinary Science Objective: To assess the inter-evaluator and intra-evaluator reliability of a software program used to extract kinematic variables by a commercially available extremity-mounted inertial measurement unit system in sound horses at the trot under soft and hard ground conditions and treadmill exercise. Animals: Thirty adult, sound and healthy French Montagne stallions. Procedures: Data collection was performed with six IMUs strapped to the distal, metacarpal, metatarsal and tibial regions of every horse. Per surface (treadmill, soft and hard ground) 10 stallions were trotted three times. Prior to the analysis done by six evaluators (three experienced, three inexperienced) the data was blinded and copied three times. For every analysis a minimum of five strides had to be selected. To assess the intra- and inter-evaluator reliability a selection of gait variables was used to calculate intra and inter correlation coefficients (ICCs) as well as variance partitioning coefficients (VPCs). Results: All of the tested gait variables showed high levels of reliability. There was no mentionable difference considering the correlation coefficients between the intra and inter reliability as well as between the three different surfaces. VPCs showed that the factor horse is by far the most responsible for any appearing variance. The experience of the evaluator had no influence on the results. Conclusions and Clinical Relevance: The software program tested in this study has a high inter- and intra-evaluator reliability under the chosen conditions for the selected variables and acts independent of the ground situation and the experience of the evaluator. On the condition of a correct application it has the potential to become a clinically relevant and reliable gait analysis tool. Frontiers Media S.A. 2021-03-04 /pmc/articles/PMC7969790/ /pubmed/33748204 http://dx.doi.org/10.3389/fvets.2021.595455 Text en Copyright © 2021 Schwarz, Vidondo, Maninchedda, Sprick, Schöpfer and Cruz. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Veterinary Science
Schwarz, Julia
Vidondo, Beatriz
Maninchedda, Ugo E.
Sprick, Miriam
Schöpfer, Melina C.
Cruz, Antonio M.
Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise
title Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise
title_full Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise
title_fullStr Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise
title_full_unstemmed Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise
title_short Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise
title_sort inter-evaluator and intra-evaluator reliability of a software program used to extract kinematic variables obtained by an extremity-mounted inertial measurement unit system in sound horses at the trot under soft and hard ground conditions and treadmill exercise
topic Veterinary Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7969790/
https://www.ncbi.nlm.nih.gov/pubmed/33748204
http://dx.doi.org/10.3389/fvets.2021.595455
work_keys_str_mv AT schwarzjulia interevaluatorandintraevaluatorreliabilityofasoftwareprogramusedtoextractkinematicvariablesobtainedbyanextremitymountedinertialmeasurementunitsysteminsoundhorsesatthetrotundersoftandhardgroundconditionsandtreadmillexercise
AT vidondobeatriz interevaluatorandintraevaluatorreliabilityofasoftwareprogramusedtoextractkinematicvariablesobtainedbyanextremitymountedinertialmeasurementunitsysteminsoundhorsesatthetrotundersoftandhardgroundconditionsandtreadmillexercise
AT manincheddaugoe interevaluatorandintraevaluatorreliabilityofasoftwareprogramusedtoextractkinematicvariablesobtainedbyanextremitymountedinertialmeasurementunitsysteminsoundhorsesatthetrotundersoftandhardgroundconditionsandtreadmillexercise
AT sprickmiriam interevaluatorandintraevaluatorreliabilityofasoftwareprogramusedtoextractkinematicvariablesobtainedbyanextremitymountedinertialmeasurementunitsysteminsoundhorsesatthetrotundersoftandhardgroundconditionsandtreadmillexercise
AT schopfermelinac interevaluatorandintraevaluatorreliabilityofasoftwareprogramusedtoextractkinematicvariablesobtainedbyanextremitymountedinertialmeasurementunitsysteminsoundhorsesatthetrotundersoftandhardgroundconditionsandtreadmillexercise
AT cruzantoniom interevaluatorandintraevaluatorreliabilityofasoftwareprogramusedtoextractkinematicvariablesobtainedbyanextremitymountedinertialmeasurementunitsysteminsoundhorsesatthetrotundersoftandhardgroundconditionsandtreadmillexercise