Cargando…
Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise
Objective: To assess the inter-evaluator and intra-evaluator reliability of a software program used to extract kinematic variables by a commercially available extremity-mounted inertial measurement unit system in sound horses at the trot under soft and hard ground conditions and treadmill exercise....
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7969790/ https://www.ncbi.nlm.nih.gov/pubmed/33748204 http://dx.doi.org/10.3389/fvets.2021.595455 |
_version_ | 1783666298911195136 |
---|---|
author | Schwarz, Julia Vidondo, Beatriz Maninchedda, Ugo E. Sprick, Miriam Schöpfer, Melina C. Cruz, Antonio M. |
author_facet | Schwarz, Julia Vidondo, Beatriz Maninchedda, Ugo E. Sprick, Miriam Schöpfer, Melina C. Cruz, Antonio M. |
author_sort | Schwarz, Julia |
collection | PubMed |
description | Objective: To assess the inter-evaluator and intra-evaluator reliability of a software program used to extract kinematic variables by a commercially available extremity-mounted inertial measurement unit system in sound horses at the trot under soft and hard ground conditions and treadmill exercise. Animals: Thirty adult, sound and healthy French Montagne stallions. Procedures: Data collection was performed with six IMUs strapped to the distal, metacarpal, metatarsal and tibial regions of every horse. Per surface (treadmill, soft and hard ground) 10 stallions were trotted three times. Prior to the analysis done by six evaluators (three experienced, three inexperienced) the data was blinded and copied three times. For every analysis a minimum of five strides had to be selected. To assess the intra- and inter-evaluator reliability a selection of gait variables was used to calculate intra and inter correlation coefficients (ICCs) as well as variance partitioning coefficients (VPCs). Results: All of the tested gait variables showed high levels of reliability. There was no mentionable difference considering the correlation coefficients between the intra and inter reliability as well as between the three different surfaces. VPCs showed that the factor horse is by far the most responsible for any appearing variance. The experience of the evaluator had no influence on the results. Conclusions and Clinical Relevance: The software program tested in this study has a high inter- and intra-evaluator reliability under the chosen conditions for the selected variables and acts independent of the ground situation and the experience of the evaluator. On the condition of a correct application it has the potential to become a clinically relevant and reliable gait analysis tool. |
format | Online Article Text |
id | pubmed-7969790 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-79697902021-03-19 Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise Schwarz, Julia Vidondo, Beatriz Maninchedda, Ugo E. Sprick, Miriam Schöpfer, Melina C. Cruz, Antonio M. Front Vet Sci Veterinary Science Objective: To assess the inter-evaluator and intra-evaluator reliability of a software program used to extract kinematic variables by a commercially available extremity-mounted inertial measurement unit system in sound horses at the trot under soft and hard ground conditions and treadmill exercise. Animals: Thirty adult, sound and healthy French Montagne stallions. Procedures: Data collection was performed with six IMUs strapped to the distal, metacarpal, metatarsal and tibial regions of every horse. Per surface (treadmill, soft and hard ground) 10 stallions were trotted three times. Prior to the analysis done by six evaluators (three experienced, three inexperienced) the data was blinded and copied three times. For every analysis a minimum of five strides had to be selected. To assess the intra- and inter-evaluator reliability a selection of gait variables was used to calculate intra and inter correlation coefficients (ICCs) as well as variance partitioning coefficients (VPCs). Results: All of the tested gait variables showed high levels of reliability. There was no mentionable difference considering the correlation coefficients between the intra and inter reliability as well as between the three different surfaces. VPCs showed that the factor horse is by far the most responsible for any appearing variance. The experience of the evaluator had no influence on the results. Conclusions and Clinical Relevance: The software program tested in this study has a high inter- and intra-evaluator reliability under the chosen conditions for the selected variables and acts independent of the ground situation and the experience of the evaluator. On the condition of a correct application it has the potential to become a clinically relevant and reliable gait analysis tool. Frontiers Media S.A. 2021-03-04 /pmc/articles/PMC7969790/ /pubmed/33748204 http://dx.doi.org/10.3389/fvets.2021.595455 Text en Copyright © 2021 Schwarz, Vidondo, Maninchedda, Sprick, Schöpfer and Cruz. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Veterinary Science Schwarz, Julia Vidondo, Beatriz Maninchedda, Ugo E. Sprick, Miriam Schöpfer, Melina C. Cruz, Antonio M. Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise |
title | Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise |
title_full | Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise |
title_fullStr | Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise |
title_full_unstemmed | Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise |
title_short | Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise |
title_sort | inter-evaluator and intra-evaluator reliability of a software program used to extract kinematic variables obtained by an extremity-mounted inertial measurement unit system in sound horses at the trot under soft and hard ground conditions and treadmill exercise |
topic | Veterinary Science |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7969790/ https://www.ncbi.nlm.nih.gov/pubmed/33748204 http://dx.doi.org/10.3389/fvets.2021.595455 |
work_keys_str_mv | AT schwarzjulia interevaluatorandintraevaluatorreliabilityofasoftwareprogramusedtoextractkinematicvariablesobtainedbyanextremitymountedinertialmeasurementunitsysteminsoundhorsesatthetrotundersoftandhardgroundconditionsandtreadmillexercise AT vidondobeatriz interevaluatorandintraevaluatorreliabilityofasoftwareprogramusedtoextractkinematicvariablesobtainedbyanextremitymountedinertialmeasurementunitsysteminsoundhorsesatthetrotundersoftandhardgroundconditionsandtreadmillexercise AT manincheddaugoe interevaluatorandintraevaluatorreliabilityofasoftwareprogramusedtoextractkinematicvariablesobtainedbyanextremitymountedinertialmeasurementunitsysteminsoundhorsesatthetrotundersoftandhardgroundconditionsandtreadmillexercise AT sprickmiriam interevaluatorandintraevaluatorreliabilityofasoftwareprogramusedtoextractkinematicvariablesobtainedbyanextremitymountedinertialmeasurementunitsysteminsoundhorsesatthetrotundersoftandhardgroundconditionsandtreadmillexercise AT schopfermelinac interevaluatorandintraevaluatorreliabilityofasoftwareprogramusedtoextractkinematicvariablesobtainedbyanextremitymountedinertialmeasurementunitsysteminsoundhorsesatthetrotundersoftandhardgroundconditionsandtreadmillexercise AT cruzantoniom interevaluatorandintraevaluatorreliabilityofasoftwareprogramusedtoextractkinematicvariablesobtainedbyanextremitymountedinertialmeasurementunitsysteminsoundhorsesatthetrotundersoftandhardgroundconditionsandtreadmillexercise |