Cargando…

The Lighting Environment, Its Metrology, and Non-visual Responses

International standard CIE S 026:2018 provides lighting professionals and field researchers in chronobiology with a method to characterize light exposures with respect to non-visual photoreception and responses. This standard defines five spectral sensitivity functions that describe optical radiatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Schlangen, Luc J. M., Price, Luke L. A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7970181/
https://www.ncbi.nlm.nih.gov/pubmed/33746879
http://dx.doi.org/10.3389/fneur.2021.624861
_version_ 1783666384955244544
author Schlangen, Luc J. M.
Price, Luke L. A.
author_facet Schlangen, Luc J. M.
Price, Luke L. A.
author_sort Schlangen, Luc J. M.
collection PubMed
description International standard CIE S 026:2018 provides lighting professionals and field researchers in chronobiology with a method to characterize light exposures with respect to non-visual photoreception and responses. This standard defines five spectral sensitivity functions that describe optical radiation for its ability to stimulate each of the five α-opic retinal photoreceptor classes that contribute to the non-visual effects of light in humans via intrinsically-photosensitive retinal ganglion cells (ipRGCs). The CIE also recently published an open-access α-opic toolbox that calculates all the quantities and ratios of the α-opic metrology in the photometric, radiometric and photon systems, based on either a measured (user-defined) spectrum or selected illuminants (A, D65, E, FL11, LED-B3) built into the toolbox. For a wide variety of ecologically-valid conditions, the melanopsin-based photoreception of ipRGCs has been shown to account for the spectral sensitivity of non-visual responses, from shifting the timing of nocturnal sleep and melatonin secretion to regulating steady-state pupil diameter. Recent findings continue to confirm that the photopigment melanopsin also plays a role in visual responses, and that melanopsin-based photoreception may have a significant influence on brightness perception and aspects of spatial vision. Although knowledge concerning the extent to which rods and cones interact with ipRGCs in driving non-visual effects is still growing, a CIE position statement recently used melanopic equivalent daylight (D65) illuminance in preliminary guidance on applying “proper light at the proper time” to manipulate non-visual responses. Further guidance on this approach is awaited from the participants of the 2nd International Workshop on Circadian and Neurophysiological Photometry (in Manchester, August 2019). The new α-opic metrology of CIE S 026 enables traceable measurements and a formal, quantitative specification of personal light exposures, photic interventions and lighting designs. Here, we apply this metrology to everyday light sources including a natural daylight time series, a range of LED lighting products and, using the toobox, to a smartphone display screen. This collection of examples suggests ways in which variations in the melanopic content of light over the day can be adopted in strategies that use light to support human health and well-being.
format Online
Article
Text
id pubmed-7970181
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-79701812021-03-19 The Lighting Environment, Its Metrology, and Non-visual Responses Schlangen, Luc J. M. Price, Luke L. A. Front Neurol Neurology International standard CIE S 026:2018 provides lighting professionals and field researchers in chronobiology with a method to characterize light exposures with respect to non-visual photoreception and responses. This standard defines five spectral sensitivity functions that describe optical radiation for its ability to stimulate each of the five α-opic retinal photoreceptor classes that contribute to the non-visual effects of light in humans via intrinsically-photosensitive retinal ganglion cells (ipRGCs). The CIE also recently published an open-access α-opic toolbox that calculates all the quantities and ratios of the α-opic metrology in the photometric, radiometric and photon systems, based on either a measured (user-defined) spectrum or selected illuminants (A, D65, E, FL11, LED-B3) built into the toolbox. For a wide variety of ecologically-valid conditions, the melanopsin-based photoreception of ipRGCs has been shown to account for the spectral sensitivity of non-visual responses, from shifting the timing of nocturnal sleep and melatonin secretion to regulating steady-state pupil diameter. Recent findings continue to confirm that the photopigment melanopsin also plays a role in visual responses, and that melanopsin-based photoreception may have a significant influence on brightness perception and aspects of spatial vision. Although knowledge concerning the extent to which rods and cones interact with ipRGCs in driving non-visual effects is still growing, a CIE position statement recently used melanopic equivalent daylight (D65) illuminance in preliminary guidance on applying “proper light at the proper time” to manipulate non-visual responses. Further guidance on this approach is awaited from the participants of the 2nd International Workshop on Circadian and Neurophysiological Photometry (in Manchester, August 2019). The new α-opic metrology of CIE S 026 enables traceable measurements and a formal, quantitative specification of personal light exposures, photic interventions and lighting designs. Here, we apply this metrology to everyday light sources including a natural daylight time series, a range of LED lighting products and, using the toobox, to a smartphone display screen. This collection of examples suggests ways in which variations in the melanopic content of light over the day can be adopted in strategies that use light to support human health and well-being. Frontiers Media S.A. 2021-03-04 /pmc/articles/PMC7970181/ /pubmed/33746879 http://dx.doi.org/10.3389/fneur.2021.624861 Text en Copyright © 2021 Schlangen and Price. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neurology
Schlangen, Luc J. M.
Price, Luke L. A.
The Lighting Environment, Its Metrology, and Non-visual Responses
title The Lighting Environment, Its Metrology, and Non-visual Responses
title_full The Lighting Environment, Its Metrology, and Non-visual Responses
title_fullStr The Lighting Environment, Its Metrology, and Non-visual Responses
title_full_unstemmed The Lighting Environment, Its Metrology, and Non-visual Responses
title_short The Lighting Environment, Its Metrology, and Non-visual Responses
title_sort lighting environment, its metrology, and non-visual responses
topic Neurology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7970181/
https://www.ncbi.nlm.nih.gov/pubmed/33746879
http://dx.doi.org/10.3389/fneur.2021.624861
work_keys_str_mv AT schlangenlucjm thelightingenvironmentitsmetrologyandnonvisualresponses
AT pricelukela thelightingenvironmentitsmetrologyandnonvisualresponses
AT schlangenlucjm lightingenvironmentitsmetrologyandnonvisualresponses
AT pricelukela lightingenvironmentitsmetrologyandnonvisualresponses