The fallacy of indexed effective orifice area charts to predict prosthesis–patient mismatch after prosthesis implantation
AIMS : Indexed effective orifice area (EOAi) charts are used to determine the likelihood of prosthesis–patient mismatch (PPM) after aortic valve replacement (AVR). The aim of this study is to validate whether these EOAi charts, based on echocardiographic normal reference values, can accurately predi...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7971169/ https://www.ncbi.nlm.nih.gov/pubmed/32243493 http://dx.doi.org/10.1093/ehjci/jeaa044 |
_version_ | 1783666564457824256 |
---|---|
author | Vriesendorp, Michiel D De Lind Van Wijngaarden, Rob A F Head, Stuart J Kappetein, Arie-Pieter Hickey, Graeme L Rao, Vivek Weissman, Neil J Reardon, Michael J Moront, Michael G Sabik, Joseph F Klautz, Robert J M |
author_facet | Vriesendorp, Michiel D De Lind Van Wijngaarden, Rob A F Head, Stuart J Kappetein, Arie-Pieter Hickey, Graeme L Rao, Vivek Weissman, Neil J Reardon, Michael J Moront, Michael G Sabik, Joseph F Klautz, Robert J M |
author_sort | Vriesendorp, Michiel D |
collection | PubMed |
description | AIMS : Indexed effective orifice area (EOAi) charts are used to determine the likelihood of prosthesis–patient mismatch (PPM) after aortic valve replacement (AVR). The aim of this study is to validate whether these EOAi charts, based on echocardiographic normal reference values, can accurately predict PPM. METHODS AND RESULTS : In the PERIcardial SurGical AOrtic Valve ReplacemeNt (PERIGON) Pivotal Trial, 986 patients with aortic valve stenosis/regurgitation underwent AVR with an Avalus valve. Patients were randomly split (50:50) into training and test sets. The mean measured EOAs for each valve size from the training set were used to create an Avalus EOAi chart. This chart was subsequently used to predict PPM in the test set and measures of diagnostic accuracy (sensitivity, specificity, and negative and positive predictive value) were assessed. PPM was defined by an EOAi ≤0.85 cm(2)/m(2,) and severe PPM was defined as EOAi ≤0.65 cm(2)/m(2). The reference values obtained from the training set ranged from 1.27 cm(2) for size 19 mm up to 1.81 cm(2) for size 27 mm. The test set had an incidence of 66% of PPM and 24% of severe PPM. The EOAi chart inaccurately predicted PPM in 30% of patients and severe PPM in 22% of patients. For the prediction of PPM, the sensitivity was 87% and the specificity 37%. For the prediction of severe PPM, the sensitivity was 13% and the specificity 98%. CONCLUSION : The use of echocardiographic normal reference values for EOAi charts to predict PPM is unreliable due to the large proportion of misclassifications. |
format | Online Article Text |
id | pubmed-7971169 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-79711692021-03-23 The fallacy of indexed effective orifice area charts to predict prosthesis–patient mismatch after prosthesis implantation Vriesendorp, Michiel D De Lind Van Wijngaarden, Rob A F Head, Stuart J Kappetein, Arie-Pieter Hickey, Graeme L Rao, Vivek Weissman, Neil J Reardon, Michael J Moront, Michael G Sabik, Joseph F Klautz, Robert J M Eur Heart J Cardiovasc Imaging Original Articles AIMS : Indexed effective orifice area (EOAi) charts are used to determine the likelihood of prosthesis–patient mismatch (PPM) after aortic valve replacement (AVR). The aim of this study is to validate whether these EOAi charts, based on echocardiographic normal reference values, can accurately predict PPM. METHODS AND RESULTS : In the PERIcardial SurGical AOrtic Valve ReplacemeNt (PERIGON) Pivotal Trial, 986 patients with aortic valve stenosis/regurgitation underwent AVR with an Avalus valve. Patients were randomly split (50:50) into training and test sets. The mean measured EOAs for each valve size from the training set were used to create an Avalus EOAi chart. This chart was subsequently used to predict PPM in the test set and measures of diagnostic accuracy (sensitivity, specificity, and negative and positive predictive value) were assessed. PPM was defined by an EOAi ≤0.85 cm(2)/m(2,) and severe PPM was defined as EOAi ≤0.65 cm(2)/m(2). The reference values obtained from the training set ranged from 1.27 cm(2) for size 19 mm up to 1.81 cm(2) for size 27 mm. The test set had an incidence of 66% of PPM and 24% of severe PPM. The EOAi chart inaccurately predicted PPM in 30% of patients and severe PPM in 22% of patients. For the prediction of PPM, the sensitivity was 87% and the specificity 37%. For the prediction of severe PPM, the sensitivity was 13% and the specificity 98%. CONCLUSION : The use of echocardiographic normal reference values for EOAi charts to predict PPM is unreliable due to the large proportion of misclassifications. Oxford University Press 2020-04-03 /pmc/articles/PMC7971169/ /pubmed/32243493 http://dx.doi.org/10.1093/ehjci/jeaa044 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of the European Society of Cardiology https://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Original Articles Vriesendorp, Michiel D De Lind Van Wijngaarden, Rob A F Head, Stuart J Kappetein, Arie-Pieter Hickey, Graeme L Rao, Vivek Weissman, Neil J Reardon, Michael J Moront, Michael G Sabik, Joseph F Klautz, Robert J M The fallacy of indexed effective orifice area charts to predict prosthesis–patient mismatch after prosthesis implantation |
title | The fallacy of indexed effective orifice area charts to predict prosthesis–patient mismatch after prosthesis implantation |
title_full | The fallacy of indexed effective orifice area charts to predict prosthesis–patient mismatch after prosthesis implantation |
title_fullStr | The fallacy of indexed effective orifice area charts to predict prosthesis–patient mismatch after prosthesis implantation |
title_full_unstemmed | The fallacy of indexed effective orifice area charts to predict prosthesis–patient mismatch after prosthesis implantation |
title_short | The fallacy of indexed effective orifice area charts to predict prosthesis–patient mismatch after prosthesis implantation |
title_sort | fallacy of indexed effective orifice area charts to predict prosthesis–patient mismatch after prosthesis implantation |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7971169/ https://www.ncbi.nlm.nih.gov/pubmed/32243493 http://dx.doi.org/10.1093/ehjci/jeaa044 |
work_keys_str_mv | AT vriesendorpmichield thefallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT delindvanwijngaardenrobaf thefallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT headstuartj thefallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT kappeteinariepieter thefallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT hickeygraemel thefallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT raovivek thefallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT weissmanneilj thefallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT reardonmichaelj thefallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT morontmichaelg thefallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT sabikjosephf thefallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT klautzrobertjm thefallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT vriesendorpmichield fallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT delindvanwijngaardenrobaf fallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT headstuartj fallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT kappeteinariepieter fallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT hickeygraemel fallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT raovivek fallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT weissmanneilj fallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT reardonmichaelj fallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT morontmichaelg fallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT sabikjosephf fallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation AT klautzrobertjm fallacyofindexedeffectiveorificeareachartstopredictprosthesispatientmismatchafterprosthesisimplantation |