Cargando…

Bed Sensor Technology for Objective Sleep Monitoring Within the Clinical Rehabilitation Setting: Observational Feasibility Study

BACKGROUND: Since adequate sleep is essential for optimal inpatient rehabilitation, there is an increased interest in sleep assessment. Unobtrusive, contactless, portable bed sensors show great potential for objective sleep analysis. OBJECTIVE: The aim of this study was to investigate the feasibilit...

Descripción completa

Detalles Bibliográficos
Autores principales: Hendriks, Maartje M S, van Lotringen, Jaap H, Vos-van der Hulst, Marije, Keijsers, Noël L W
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7971768/
https://www.ncbi.nlm.nih.gov/pubmed/33555268
http://dx.doi.org/10.2196/24339
_version_ 1783666651293548544
author Hendriks, Maartje M S
van Lotringen, Jaap H
Vos-van der Hulst, Marije
Keijsers, Noël L W
author_facet Hendriks, Maartje M S
van Lotringen, Jaap H
Vos-van der Hulst, Marije
Keijsers, Noël L W
author_sort Hendriks, Maartje M S
collection PubMed
description BACKGROUND: Since adequate sleep is essential for optimal inpatient rehabilitation, there is an increased interest in sleep assessment. Unobtrusive, contactless, portable bed sensors show great potential for objective sleep analysis. OBJECTIVE: The aim of this study was to investigate the feasibility of a bed sensor for continuous sleep monitoring overnight in a clinical rehabilitation center. METHODS: Patients with incomplete spinal cord injury (iSCI) or stroke were monitored overnight for a 1-week period during their in-hospital rehabilitation using the Emfit QS bed sensor. Feasibility was examined based on missing measurement nights, coverage percentages, and missing periods of heart rate (HR) and respiratory rate (RR). Furthermore, descriptive data of sleep-related parameters (nocturnal HR, RR, movement activity, and bed exits) were reported. RESULTS: In total, 24 participants (12 iSCI, 12 stroke) were measured. Of the 132 nights, 5 (3.8%) missed sensor data due to Wi-Fi (2), slipping away (1), or unknown (2) errors. Coverage percentages of HR and RR were 97% and 93% for iSCI and 99% and 97% for stroke participants. Two-thirds of the missing HR and RR periods had a short duration of ≤120 seconds. Patients with an iSCI had an average nocturnal HR of 72 (SD 13) beats per minute (bpm), RR of 16 (SD 3) cycles per minute (cpm), and movement activity of 239 (SD 116) activity points, and had 86 reported and 84 recorded bed exits. Patients with a stroke had an average nocturnal HR of 61 (SD 8) bpm, RR of 15 (SD 1) cpm, and movement activity of 136 (SD 49) activity points, and 42 reported and 57 recorded bed exits. Patients with an iSCI had significantly higher nocturnal HR (t(18)=−2.1, P=.04) and movement activity (t(18)=−1.2, P=.02) compared to stroke patients. Furthermore, there was a difference between self-reported and recorded bed exits per night in 26% and 38% of the nights for iSCI and stroke patients, respectively. CONCLUSIONS: It is feasible to implement the bed sensor for continuous sleep monitoring in the clinical rehabilitation setting. This study provides a good foundation for further bed sensor development addressing sleep types and sleep disorders to optimize care for rehabilitants.
format Online
Article
Text
id pubmed-7971768
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-79717682021-03-24 Bed Sensor Technology for Objective Sleep Monitoring Within the Clinical Rehabilitation Setting: Observational Feasibility Study Hendriks, Maartje M S van Lotringen, Jaap H Vos-van der Hulst, Marije Keijsers, Noël L W JMIR Mhealth Uhealth Original Paper BACKGROUND: Since adequate sleep is essential for optimal inpatient rehabilitation, there is an increased interest in sleep assessment. Unobtrusive, contactless, portable bed sensors show great potential for objective sleep analysis. OBJECTIVE: The aim of this study was to investigate the feasibility of a bed sensor for continuous sleep monitoring overnight in a clinical rehabilitation center. METHODS: Patients with incomplete spinal cord injury (iSCI) or stroke were monitored overnight for a 1-week period during their in-hospital rehabilitation using the Emfit QS bed sensor. Feasibility was examined based on missing measurement nights, coverage percentages, and missing periods of heart rate (HR) and respiratory rate (RR). Furthermore, descriptive data of sleep-related parameters (nocturnal HR, RR, movement activity, and bed exits) were reported. RESULTS: In total, 24 participants (12 iSCI, 12 stroke) were measured. Of the 132 nights, 5 (3.8%) missed sensor data due to Wi-Fi (2), slipping away (1), or unknown (2) errors. Coverage percentages of HR and RR were 97% and 93% for iSCI and 99% and 97% for stroke participants. Two-thirds of the missing HR and RR periods had a short duration of ≤120 seconds. Patients with an iSCI had an average nocturnal HR of 72 (SD 13) beats per minute (bpm), RR of 16 (SD 3) cycles per minute (cpm), and movement activity of 239 (SD 116) activity points, and had 86 reported and 84 recorded bed exits. Patients with a stroke had an average nocturnal HR of 61 (SD 8) bpm, RR of 15 (SD 1) cpm, and movement activity of 136 (SD 49) activity points, and 42 reported and 57 recorded bed exits. Patients with an iSCI had significantly higher nocturnal HR (t(18)=−2.1, P=.04) and movement activity (t(18)=−1.2, P=.02) compared to stroke patients. Furthermore, there was a difference between self-reported and recorded bed exits per night in 26% and 38% of the nights for iSCI and stroke patients, respectively. CONCLUSIONS: It is feasible to implement the bed sensor for continuous sleep monitoring in the clinical rehabilitation setting. This study provides a good foundation for further bed sensor development addressing sleep types and sleep disorders to optimize care for rehabilitants. JMIR Publications 2021-02-08 /pmc/articles/PMC7971768/ /pubmed/33555268 http://dx.doi.org/10.2196/24339 Text en ©Maartje M S Hendriks, Jaap H van Lotringen, Marije Vos-van der Hulst, Noël L W Keijsers. Originally published in JMIR mHealth and uHealth (http://mhealth.jmir.org), 08.02.2021. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mHealth and uHealth, is properly cited. The complete bibliographic information, a link to the original publication on http://mhealth.jmir.org/, as well as this copyright and license information must be included.
spellingShingle Original Paper
Hendriks, Maartje M S
van Lotringen, Jaap H
Vos-van der Hulst, Marije
Keijsers, Noël L W
Bed Sensor Technology for Objective Sleep Monitoring Within the Clinical Rehabilitation Setting: Observational Feasibility Study
title Bed Sensor Technology for Objective Sleep Monitoring Within the Clinical Rehabilitation Setting: Observational Feasibility Study
title_full Bed Sensor Technology for Objective Sleep Monitoring Within the Clinical Rehabilitation Setting: Observational Feasibility Study
title_fullStr Bed Sensor Technology for Objective Sleep Monitoring Within the Clinical Rehabilitation Setting: Observational Feasibility Study
title_full_unstemmed Bed Sensor Technology for Objective Sleep Monitoring Within the Clinical Rehabilitation Setting: Observational Feasibility Study
title_short Bed Sensor Technology for Objective Sleep Monitoring Within the Clinical Rehabilitation Setting: Observational Feasibility Study
title_sort bed sensor technology for objective sleep monitoring within the clinical rehabilitation setting: observational feasibility study
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7971768/
https://www.ncbi.nlm.nih.gov/pubmed/33555268
http://dx.doi.org/10.2196/24339
work_keys_str_mv AT hendriksmaartjems bedsensortechnologyforobjectivesleepmonitoringwithintheclinicalrehabilitationsettingobservationalfeasibilitystudy
AT vanlotringenjaaph bedsensortechnologyforobjectivesleepmonitoringwithintheclinicalrehabilitationsettingobservationalfeasibilitystudy
AT vosvanderhulstmarije bedsensortechnologyforobjectivesleepmonitoringwithintheclinicalrehabilitationsettingobservationalfeasibilitystudy
AT keijsersnoellw bedsensortechnologyforobjectivesleepmonitoringwithintheclinicalrehabilitationsettingobservationalfeasibilitystudy