Cargando…

Measurement of the dependence of ultra diluted gas transmittance on the size of the detector

We show that measured optical transmittance of an ultra thin gas depends on the detector size. To this end we conducted an experiment that compares transmittances measured in parallel with a pair of detectors with different diameters ranging from 2 to 200 [Formula: see text] m. A Tunable Diode Laser...

Descripción completa

Detalles Bibliográficos
Autor principal: Ratajczak, Jakub M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7973539/
https://www.ncbi.nlm.nih.gov/pubmed/33737594
http://dx.doi.org/10.1038/s41598-021-85568-w
_version_ 1783666862514503680
author Ratajczak, Jakub M.
author_facet Ratajczak, Jakub M.
author_sort Ratajczak, Jakub M.
collection PubMed
description We show that measured optical transmittance of an ultra thin gas depends on the detector size. To this end we conducted an experiment that compares transmittances measured in parallel with a pair of detectors with different diameters ranging from 2 to 200 [Formula: see text] m. A Tunable Diode Laser Absorption Spectroscopy type system was used. Transmittance of [Formula: see text]  10[Formula: see text] mbar water vapor on NIR absorption line [Formula: see text]  nm was measured using a 61.6 m long multi-pass cell placed inside the [Formula: see text]  300 l vacuum chamber. The result of the experiment shows higher transmittances when the measurement is performed using smaller detectors. The difference reaches as much as [Formula: see text] %, which is greater than 0 with [Formula: see text] statistical significance. Qualitatively it is in agreement with the recently developed model of thin gas optical transmittance taking into account the quantum mechanical effects of spreading of the wave functions of individual gas particles.
format Online
Article
Text
id pubmed-7973539
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-79735392021-03-19 Measurement of the dependence of ultra diluted gas transmittance on the size of the detector Ratajczak, Jakub M. Sci Rep Article We show that measured optical transmittance of an ultra thin gas depends on the detector size. To this end we conducted an experiment that compares transmittances measured in parallel with a pair of detectors with different diameters ranging from 2 to 200 [Formula: see text] m. A Tunable Diode Laser Absorption Spectroscopy type system was used. Transmittance of [Formula: see text]  10[Formula: see text] mbar water vapor on NIR absorption line [Formula: see text]  nm was measured using a 61.6 m long multi-pass cell placed inside the [Formula: see text]  300 l vacuum chamber. The result of the experiment shows higher transmittances when the measurement is performed using smaller detectors. The difference reaches as much as [Formula: see text] %, which is greater than 0 with [Formula: see text] statistical significance. Qualitatively it is in agreement with the recently developed model of thin gas optical transmittance taking into account the quantum mechanical effects of spreading of the wave functions of individual gas particles. Nature Publishing Group UK 2021-03-18 /pmc/articles/PMC7973539/ /pubmed/33737594 http://dx.doi.org/10.1038/s41598-021-85568-w Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Ratajczak, Jakub M.
Measurement of the dependence of ultra diluted gas transmittance on the size of the detector
title Measurement of the dependence of ultra diluted gas transmittance on the size of the detector
title_full Measurement of the dependence of ultra diluted gas transmittance on the size of the detector
title_fullStr Measurement of the dependence of ultra diluted gas transmittance on the size of the detector
title_full_unstemmed Measurement of the dependence of ultra diluted gas transmittance on the size of the detector
title_short Measurement of the dependence of ultra diluted gas transmittance on the size of the detector
title_sort measurement of the dependence of ultra diluted gas transmittance on the size of the detector
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7973539/
https://www.ncbi.nlm.nih.gov/pubmed/33737594
http://dx.doi.org/10.1038/s41598-021-85568-w
work_keys_str_mv AT ratajczakjakubm measurementofthedependenceofultradilutedgastransmittanceonthesizeofthedetector