Cargando…

Obturator dislocation of the hip associated with ipsilateral quadrilateral plate fracture: A rare case report

Traumatic hip dislocations typically result of high-energy trauma and frequently involve young patients. The obturator dislocation is not a common condition and rarely combined with acetabular fracture. We report a rare case of a 48-year-old male patient with a trauma of the left hip following a car...

Descripción completa

Detalles Bibliográficos
Autores principales: Ceri, Lorenzo, Zanna, Luigi, Buzzi, Roberto, De Biase, Pietro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7974022/
https://www.ncbi.nlm.nih.gov/pubmed/33763515
http://dx.doi.org/10.1016/j.tcr.2021.100451
_version_ 1783666909091201024
author Ceri, Lorenzo
Zanna, Luigi
Buzzi, Roberto
De Biase, Pietro
author_facet Ceri, Lorenzo
Zanna, Luigi
Buzzi, Roberto
De Biase, Pietro
author_sort Ceri, Lorenzo
collection PubMed
description Traumatic hip dislocations typically result of high-energy trauma and frequently involve young patients. The obturator dislocation is not a common condition and rarely combined with acetabular fracture. We report a rare case of a 48-year-old male patient with a trauma of the left hip following a car-vs-car frontal accident. He presented with an obturator hip dislocation combined with ipsilateral quadrilateral plate fracture. The patient underwent a clinical and imaging evaluation to identify the acetabular fracture dislocation. The CT scan showed a severe dislocation of the acetabular medial wall. Closed reduction under conscious sedation was performed in Emergency Department. The patient underwent open reduction and internal fixation. During surgery, obturator nerve was entrapped inside the fracture rim and then it was released. No intra-operative complications were observed. The patient was followed, with accurate clinical and radiological follow up assessments for 24 months reporting excellent clinical outcomes according to Oxford Hip Score (47/48 points), a good hip range of motion and a complete recovery of basic activities of daily living. After two years of follow-up, no evidence of femoral head necrosis was reported and the patient returned to sport activity.
format Online
Article
Text
id pubmed-7974022
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-79740222021-03-23 Obturator dislocation of the hip associated with ipsilateral quadrilateral plate fracture: A rare case report Ceri, Lorenzo Zanna, Luigi Buzzi, Roberto De Biase, Pietro Trauma Case Rep Case Report Traumatic hip dislocations typically result of high-energy trauma and frequently involve young patients. The obturator dislocation is not a common condition and rarely combined with acetabular fracture. We report a rare case of a 48-year-old male patient with a trauma of the left hip following a car-vs-car frontal accident. He presented with an obturator hip dislocation combined with ipsilateral quadrilateral plate fracture. The patient underwent a clinical and imaging evaluation to identify the acetabular fracture dislocation. The CT scan showed a severe dislocation of the acetabular medial wall. Closed reduction under conscious sedation was performed in Emergency Department. The patient underwent open reduction and internal fixation. During surgery, obturator nerve was entrapped inside the fracture rim and then it was released. No intra-operative complications were observed. The patient was followed, with accurate clinical and radiological follow up assessments for 24 months reporting excellent clinical outcomes according to Oxford Hip Score (47/48 points), a good hip range of motion and a complete recovery of basic activities of daily living. After two years of follow-up, no evidence of femoral head necrosis was reported and the patient returned to sport activity. Elsevier 2021-03-11 /pmc/articles/PMC7974022/ /pubmed/33763515 http://dx.doi.org/10.1016/j.tcr.2021.100451 Text en © 2021 The Authors. Published by Elsevier Ltd. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Ceri, Lorenzo
Zanna, Luigi
Buzzi, Roberto
De Biase, Pietro
Obturator dislocation of the hip associated with ipsilateral quadrilateral plate fracture: A rare case report
title Obturator dislocation of the hip associated with ipsilateral quadrilateral plate fracture: A rare case report
title_full Obturator dislocation of the hip associated with ipsilateral quadrilateral plate fracture: A rare case report
title_fullStr Obturator dislocation of the hip associated with ipsilateral quadrilateral plate fracture: A rare case report
title_full_unstemmed Obturator dislocation of the hip associated with ipsilateral quadrilateral plate fracture: A rare case report
title_short Obturator dislocation of the hip associated with ipsilateral quadrilateral plate fracture: A rare case report
title_sort obturator dislocation of the hip associated with ipsilateral quadrilateral plate fracture: a rare case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7974022/
https://www.ncbi.nlm.nih.gov/pubmed/33763515
http://dx.doi.org/10.1016/j.tcr.2021.100451
work_keys_str_mv AT cerilorenzo obturatordislocationofthehipassociatedwithipsilateralquadrilateralplatefractureararecasereport
AT zannaluigi obturatordislocationofthehipassociatedwithipsilateralquadrilateralplatefractureararecasereport
AT buzziroberto obturatordislocationofthehipassociatedwithipsilateralquadrilateralplatefractureararecasereport
AT debiasepietro obturatordislocationofthehipassociatedwithipsilateralquadrilateralplatefractureararecasereport