Symmetry of postural tone in right homogeneous functional laterality evaluated by Fukuda test
BACKGROUND: To study the symmetry of postural tone in subjects with right homogeneous functional laterality. METHODS: It was an observational study; we looked for the right homogeneous functional laterality by clinical tests on the eyes, feet and hands. Postural tone was evaluated by the Fikuda test...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Mattioli 1885
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7975945/ https://www.ncbi.nlm.nih.gov/pubmed/33682820 http://dx.doi.org/10.23750/abm.v92i1.9025 |
_version_ | 1783666998882861056 |
---|---|
author | Arabi, Hafid Adarmouch, Latifa |
author_facet | Arabi, Hafid Adarmouch, Latifa |
author_sort | Arabi, Hafid |
collection | PubMed |
description | BACKGROUND: To study the symmetry of postural tone in subjects with right homogeneous functional laterality. METHODS: It was an observational study; we looked for the right homogeneous functional laterality by clinical tests on the eyes, feet and hands. Postural tone was evaluated by the Fikuda test. We measured the mean value of the Fikuda angle and in cm walking forward or backward compared to the A axis and the deviation to the left or right compared to the B walking axis. These two axes were perpendicular. RESULTS: There were 80 homogeneous right-hand adult subjects. There were 52 males (63, 52%) and 28 females (36, 47%). The median age was 34, 85 years (23, 42- 47, 57). For the studied population the deviation angle according to Fukuda test was 0° (-15°; 15°), the subjects stepped 81 cm (52; 110) forward without deviation from the B walking axis 0cm (-14; 20). Male subjects remained on the walking axis 0° (-17°, 19°) while stepping 81 cm (51, 119) forward without right-left deviation 0 cm (-17, 19). Female subjects stepped (83 cm (52; 110) forward, and away from the walking axis (3 cm (-23; 21)), without deviation 0° (-17°; 19°). CONCLUSION: The functional homogeneous laterality did not influence postural tone. The lateralization is a complex phenomenon. (www.actabiomedica.it) |
format | Online Article Text |
id | pubmed-7975945 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Mattioli 1885 |
record_format | MEDLINE/PubMed |
spelling | pubmed-79759452021-03-24 Symmetry of postural tone in right homogeneous functional laterality evaluated by Fukuda test Arabi, Hafid Adarmouch, Latifa Acta Biomed Original Article BACKGROUND: To study the symmetry of postural tone in subjects with right homogeneous functional laterality. METHODS: It was an observational study; we looked for the right homogeneous functional laterality by clinical tests on the eyes, feet and hands. Postural tone was evaluated by the Fikuda test. We measured the mean value of the Fikuda angle and in cm walking forward or backward compared to the A axis and the deviation to the left or right compared to the B walking axis. These two axes were perpendicular. RESULTS: There were 80 homogeneous right-hand adult subjects. There were 52 males (63, 52%) and 28 females (36, 47%). The median age was 34, 85 years (23, 42- 47, 57). For the studied population the deviation angle according to Fukuda test was 0° (-15°; 15°), the subjects stepped 81 cm (52; 110) forward without deviation from the B walking axis 0cm (-14; 20). Male subjects remained on the walking axis 0° (-17°, 19°) while stepping 81 cm (51, 119) forward without right-left deviation 0 cm (-17, 19). Female subjects stepped (83 cm (52; 110) forward, and away from the walking axis (3 cm (-23; 21)), without deviation 0° (-17°; 19°). CONCLUSION: The functional homogeneous laterality did not influence postural tone. The lateralization is a complex phenomenon. (www.actabiomedica.it) Mattioli 1885 2021 2020-11-30 /pmc/articles/PMC7975945/ /pubmed/33682820 http://dx.doi.org/10.23750/abm.v92i1.9025 Text en Copyright: © 2020 ACTA BIO MEDICA SOCIETY OF MEDICINE AND NATURAL SCIENCES OF PARMA http://creativecommons.org/licenses/by-nc-sa/4.0 This work is licensed under a Creative Commons Attribution 4.0 International License |
spellingShingle | Original Article Arabi, Hafid Adarmouch, Latifa Symmetry of postural tone in right homogeneous functional laterality evaluated by Fukuda test |
title | Symmetry of postural tone in right homogeneous functional laterality evaluated by Fukuda test |
title_full | Symmetry of postural tone in right homogeneous functional laterality evaluated by Fukuda test |
title_fullStr | Symmetry of postural tone in right homogeneous functional laterality evaluated by Fukuda test |
title_full_unstemmed | Symmetry of postural tone in right homogeneous functional laterality evaluated by Fukuda test |
title_short | Symmetry of postural tone in right homogeneous functional laterality evaluated by Fukuda test |
title_sort | symmetry of postural tone in right homogeneous functional laterality evaluated by fukuda test |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7975945/ https://www.ncbi.nlm.nih.gov/pubmed/33682820 http://dx.doi.org/10.23750/abm.v92i1.9025 |
work_keys_str_mv | AT arabihafid symmetryofposturaltoneinrighthomogeneousfunctionallateralityevaluatedbyfukudatest AT adarmouchlatifa symmetryofposturaltoneinrighthomogeneousfunctionallateralityevaluatedbyfukudatest |