Cargando…
Monte Carlo Simulation of Errors for N-localizer Systems in Stereotactic Neurosurgery: Novel Proposals for Improvements
Introduction: Frame-based stereotaxis has been widely utilized for precise neurosurgical procedures throughout the world for nearly 40 years. The N-localizer is an integral component of most of the extant systems. Analysis of targeting errors related to the N-localizer has not been carried out in su...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7977485/ https://www.ncbi.nlm.nih.gov/pubmed/33758694 http://dx.doi.org/10.7759/cureus.13393 |
_version_ | 1783667122938839040 |
---|---|
author | Sedrak, Mark Alaminos-Bouza, Armando L Bruna, Andres Brown, Russell A |
author_facet | Sedrak, Mark Alaminos-Bouza, Armando L Bruna, Andres Brown, Russell A |
author_sort | Sedrak, Mark |
collection | PubMed |
description | Introduction: Frame-based stereotaxis has been widely utilized for precise neurosurgical procedures throughout the world for nearly 40 years. The N-localizer is an integral component of most of the extant systems. Analysis of targeting errors related to the N-localizer has not been carried out in sufficient detail. We highlight these potential errors and develop methods to reduce them. Methods: N-localizer systems comprising three and four N-localizers of various geometries were analyzed using Monte Carlo (MC) simulations. The simulations included native and altered geometric dimensions (Width [W] x Height [H]). Errors were computed using the MC simulations that included the x- and y-axes of vertically oriented rods, that altered the W/H ratio, and that added a fourth N-localizer to a three N-localizer system. Results: The inclusion of an overdetermined system of equations and the geometries of the N-localizer systems had significant effects on target errors. Root Mean Square Errors (RMS-e) computed via millions of MC iterations for each study demonstrated that errors were reduced by (1) inclusion of the x- and y-coordinates of the vertically oriented rods, (2) a greater triangular area enclosed by the diagonal fiducials of the N-localizer system (stereotactic triangle), (3) a larger W/H ratio, and (4) an N-localizer system that comprised four N-localizers. Conclusion: Monte Carlo simulations of Root Mean Square error (RMS-e) is a useful technique to understand targeting while using N-localizer systems in stereotactic neurosurgery. The application of vertical rod positions enhances computational accuracy and can be performed on any N-localizer system. Keeping the target point within the stereotactic triangle enclosed by the diagonal rods can also reduce errors. Additional optimizations of N-localizer geometry may also reduce potential targeting errors. Further analysis is needed to confirm these findings which may have clinical importance. |
format | Online Article Text |
id | pubmed-7977485 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-79774852021-03-22 Monte Carlo Simulation of Errors for N-localizer Systems in Stereotactic Neurosurgery: Novel Proposals for Improvements Sedrak, Mark Alaminos-Bouza, Armando L Bruna, Andres Brown, Russell A Cureus Neurosurgery Introduction: Frame-based stereotaxis has been widely utilized for precise neurosurgical procedures throughout the world for nearly 40 years. The N-localizer is an integral component of most of the extant systems. Analysis of targeting errors related to the N-localizer has not been carried out in sufficient detail. We highlight these potential errors and develop methods to reduce them. Methods: N-localizer systems comprising three and four N-localizers of various geometries were analyzed using Monte Carlo (MC) simulations. The simulations included native and altered geometric dimensions (Width [W] x Height [H]). Errors were computed using the MC simulations that included the x- and y-axes of vertically oriented rods, that altered the W/H ratio, and that added a fourth N-localizer to a three N-localizer system. Results: The inclusion of an overdetermined system of equations and the geometries of the N-localizer systems had significant effects on target errors. Root Mean Square Errors (RMS-e) computed via millions of MC iterations for each study demonstrated that errors were reduced by (1) inclusion of the x- and y-coordinates of the vertically oriented rods, (2) a greater triangular area enclosed by the diagonal fiducials of the N-localizer system (stereotactic triangle), (3) a larger W/H ratio, and (4) an N-localizer system that comprised four N-localizers. Conclusion: Monte Carlo simulations of Root Mean Square error (RMS-e) is a useful technique to understand targeting while using N-localizer systems in stereotactic neurosurgery. The application of vertical rod positions enhances computational accuracy and can be performed on any N-localizer system. Keeping the target point within the stereotactic triangle enclosed by the diagonal rods can also reduce errors. Additional optimizations of N-localizer geometry may also reduce potential targeting errors. Further analysis is needed to confirm these findings which may have clinical importance. Cureus 2021-02-17 /pmc/articles/PMC7977485/ /pubmed/33758694 http://dx.doi.org/10.7759/cureus.13393 Text en Copyright © 2021, Sedrak et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Neurosurgery Sedrak, Mark Alaminos-Bouza, Armando L Bruna, Andres Brown, Russell A Monte Carlo Simulation of Errors for N-localizer Systems in Stereotactic Neurosurgery: Novel Proposals for Improvements |
title | Monte Carlo Simulation of Errors for N-localizer Systems in Stereotactic Neurosurgery: Novel Proposals for Improvements |
title_full | Monte Carlo Simulation of Errors for N-localizer Systems in Stereotactic Neurosurgery: Novel Proposals for Improvements |
title_fullStr | Monte Carlo Simulation of Errors for N-localizer Systems in Stereotactic Neurosurgery: Novel Proposals for Improvements |
title_full_unstemmed | Monte Carlo Simulation of Errors for N-localizer Systems in Stereotactic Neurosurgery: Novel Proposals for Improvements |
title_short | Monte Carlo Simulation of Errors for N-localizer Systems in Stereotactic Neurosurgery: Novel Proposals for Improvements |
title_sort | monte carlo simulation of errors for n-localizer systems in stereotactic neurosurgery: novel proposals for improvements |
topic | Neurosurgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7977485/ https://www.ncbi.nlm.nih.gov/pubmed/33758694 http://dx.doi.org/10.7759/cureus.13393 |
work_keys_str_mv | AT sedrakmark montecarlosimulationoferrorsfornlocalizersystemsinstereotacticneurosurgerynovelproposalsforimprovements AT alaminosbouzaarmandol montecarlosimulationoferrorsfornlocalizersystemsinstereotacticneurosurgerynovelproposalsforimprovements AT brunaandres montecarlosimulationoferrorsfornlocalizersystemsinstereotacticneurosurgerynovelproposalsforimprovements AT brownrussella montecarlosimulationoferrorsfornlocalizersystemsinstereotacticneurosurgerynovelproposalsforimprovements |