Radiation dose management systems—requirements and recommendations for users from the ESR EuroSafe Imaging initiative
ABSTRACT: The European Directive 2013/59/Euratom requires member states of the European Union to ensure justification and optimisation of radiological procedures and store information on patient exposure for analysis and quality assurance. The EuroSafe Imaging campaign of the European Society of Rad...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7979596/ https://www.ncbi.nlm.nih.gov/pubmed/32959080 http://dx.doi.org/10.1007/s00330-020-07290-x |
_version_ | 1783667294215340032 |
---|---|
author | Loose, Reinhard W. Vano, Eliseo Mildenberger, Peter Tsapaki, Virginia Caramella, Davide Sjöberg, Johan Paulo, Graciano Torresin, Alberto Schindera, Sebastian Frija, Guy Damilakis, John |
author_facet | Loose, Reinhard W. Vano, Eliseo Mildenberger, Peter Tsapaki, Virginia Caramella, Davide Sjöberg, Johan Paulo, Graciano Torresin, Alberto Schindera, Sebastian Frija, Guy Damilakis, John |
author_sort | Loose, Reinhard W. |
collection | PubMed |
description | ABSTRACT: The European Directive 2013/59/Euratom requires member states of the European Union to ensure justification and optimisation of radiological procedures and store information on patient exposure for analysis and quality assurance. The EuroSafe Imaging campaign of the European Society of Radiology created a working group (WG) on “Dose Management” with the aim to provide European recommendations on the implementation of dose management systems (DMS) in clinical practice. The WG follows Action 4: “Promote dose management systems to establish local, national, and European diagnostic reference levels (DRL)” of the EuroSafe Imaging Call for Action 2018. DMS are designed for medical practitioners, radiographers, medical physics experts (MPE) and other health professionals involved in imaging to support their tasks and duties of radiation protection in accordance with local and national requirements. The WG analysed requirements and critical points when installing a DMS and classified the individual functions at different performance levels. KEY POINTS: • DMS are very helpful software tools for monitoring patient exposure, optimisation, compliance with DRLs and quality assurance. • DMS can help to fulfil dosimetric aspects of the European Directive 2013/59/Euratom. • The EuroSafe WG analyses DMS requirements and gives recommendations for users. |
format | Online Article Text |
id | pubmed-7979596 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-79795962021-04-05 Radiation dose management systems—requirements and recommendations for users from the ESR EuroSafe Imaging initiative Loose, Reinhard W. Vano, Eliseo Mildenberger, Peter Tsapaki, Virginia Caramella, Davide Sjöberg, Johan Paulo, Graciano Torresin, Alberto Schindera, Sebastian Frija, Guy Damilakis, John Eur Radiol Radiological Education ABSTRACT: The European Directive 2013/59/Euratom requires member states of the European Union to ensure justification and optimisation of radiological procedures and store information on patient exposure for analysis and quality assurance. The EuroSafe Imaging campaign of the European Society of Radiology created a working group (WG) on “Dose Management” with the aim to provide European recommendations on the implementation of dose management systems (DMS) in clinical practice. The WG follows Action 4: “Promote dose management systems to establish local, national, and European diagnostic reference levels (DRL)” of the EuroSafe Imaging Call for Action 2018. DMS are designed for medical practitioners, radiographers, medical physics experts (MPE) and other health professionals involved in imaging to support their tasks and duties of radiation protection in accordance with local and national requirements. The WG analysed requirements and critical points when installing a DMS and classified the individual functions at different performance levels. KEY POINTS: • DMS are very helpful software tools for monitoring patient exposure, optimisation, compliance with DRLs and quality assurance. • DMS can help to fulfil dosimetric aspects of the European Directive 2013/59/Euratom. • The EuroSafe WG analyses DMS requirements and gives recommendations for users. Springer Berlin Heidelberg 2020-09-21 2021 /pmc/articles/PMC7979596/ /pubmed/32959080 http://dx.doi.org/10.1007/s00330-020-07290-x Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Radiological Education Loose, Reinhard W. Vano, Eliseo Mildenberger, Peter Tsapaki, Virginia Caramella, Davide Sjöberg, Johan Paulo, Graciano Torresin, Alberto Schindera, Sebastian Frija, Guy Damilakis, John Radiation dose management systems—requirements and recommendations for users from the ESR EuroSafe Imaging initiative |
title | Radiation dose management systems—requirements and recommendations for users from the ESR EuroSafe Imaging initiative |
title_full | Radiation dose management systems—requirements and recommendations for users from the ESR EuroSafe Imaging initiative |
title_fullStr | Radiation dose management systems—requirements and recommendations for users from the ESR EuroSafe Imaging initiative |
title_full_unstemmed | Radiation dose management systems—requirements and recommendations for users from the ESR EuroSafe Imaging initiative |
title_short | Radiation dose management systems—requirements and recommendations for users from the ESR EuroSafe Imaging initiative |
title_sort | radiation dose management systems—requirements and recommendations for users from the esr eurosafe imaging initiative |
topic | Radiological Education |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7979596/ https://www.ncbi.nlm.nih.gov/pubmed/32959080 http://dx.doi.org/10.1007/s00330-020-07290-x |
work_keys_str_mv | AT loosereinhardw radiationdosemanagementsystemsrequirementsandrecommendationsforusersfromtheesreurosafeimaginginitiative AT vanoeliseo radiationdosemanagementsystemsrequirementsandrecommendationsforusersfromtheesreurosafeimaginginitiative AT mildenbergerpeter radiationdosemanagementsystemsrequirementsandrecommendationsforusersfromtheesreurosafeimaginginitiative AT tsapakivirginia radiationdosemanagementsystemsrequirementsandrecommendationsforusersfromtheesreurosafeimaginginitiative AT caramelladavide radiationdosemanagementsystemsrequirementsandrecommendationsforusersfromtheesreurosafeimaginginitiative AT sjobergjohan radiationdosemanagementsystemsrequirementsandrecommendationsforusersfromtheesreurosafeimaginginitiative AT paulograciano radiationdosemanagementsystemsrequirementsandrecommendationsforusersfromtheesreurosafeimaginginitiative AT torresinalberto radiationdosemanagementsystemsrequirementsandrecommendationsforusersfromtheesreurosafeimaginginitiative AT schinderasebastian radiationdosemanagementsystemsrequirementsandrecommendationsforusersfromtheesreurosafeimaginginitiative AT frijaguy radiationdosemanagementsystemsrequirementsandrecommendationsforusersfromtheesreurosafeimaginginitiative AT damilakisjohn radiationdosemanagementsystemsrequirementsandrecommendationsforusersfromtheesreurosafeimaginginitiative AT radiationdosemanagementsystemsrequirementsandrecommendationsforusersfromtheesreurosafeimaginginitiative |