Cargando…

A randomized noninferiority trial comparing the diagnostic yield of the 25G ProCore needle to the standard 25G needle in suspicious pancreatic lesions

BACKGROUND AND OBJECTIVES: The aim of the study was to perform the first randomized trial comparing the diagnostic yield, bloodiness, and cellularity of the 25G standard needle (25S) and the 25G ProCore™ needle (25P). MATERIALS AND METHODS: All patients referred to the tertiary care referral center...

Descripción completa

Detalles Bibliográficos
Autores principales: Hassan, Galab M., Wyse, Jonathan M., Paquin, Sarto C, Gariepy, Gilles, Albadine, Roula, Mâsse, Benoît, Trottier, Helen, Sahai, Anand V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7980691/
https://www.ncbi.nlm.nih.gov/pubmed/33402551
http://dx.doi.org/10.4103/eus.eus_69_20
_version_ 1783667478969188352
author Hassan, Galab M.
Wyse, Jonathan M.
Paquin, Sarto C
Gariepy, Gilles
Albadine, Roula
Mâsse, Benoît
Trottier, Helen
Sahai, Anand V.
author_facet Hassan, Galab M.
Wyse, Jonathan M.
Paquin, Sarto C
Gariepy, Gilles
Albadine, Roula
Mâsse, Benoît
Trottier, Helen
Sahai, Anand V.
author_sort Hassan, Galab M.
collection PubMed
description BACKGROUND AND OBJECTIVES: The aim of the study was to perform the first randomized trial comparing the diagnostic yield, bloodiness, and cellularity of the 25G standard needle (25S) and the 25G ProCore™ needle (25P). MATERIALS AND METHODS: All patients referred to the tertiary care referral center for EUS guided fine-needle aspiration (EUS-FNA) of suspicious solid pancreatic lesions were eligible. EUS-FNA was performed in each lesion with both 25S and 25P needles (the choice of the first needle was randomized), using a multipass sampling pattern, without stylet or suction. Rapid on-site evaluation was used when possible. Pap-stained slides were read by a single experienced cytopathologist, blinded to the needle type. RESULTS: One hundred and forty-three patients were recruited. Samples were positive for cancer in 122/143 (85.3%) with the 25S needle versus 126/143 (88.1%) with the 25P needle, negative in 17/143 (11.9%) with the 25S needle versus 13/143 (9.1%) with the 25P needle, and suspicious in 4/143 (2.8%) with each needle. There was no difference in any outcome based on the type of the first needle. No carryover effect was detected (P = 0.214; NS). Cumulative logistic regression analyses showed no associations between the type of needle and diagnostic yield for cancer, cellularity, or bloodiness. The difference in the yield for cancer was 2.9% (−4.2; 10.1%); with the confidence interval upper within the predetermined noninferiority margin of 15%. CONCLUSION: The 25S needle is noninferior to the 25P needle for diagnosing cancer in suspicious pancreatic lesions.
format Online
Article
Text
id pubmed-7980691
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-79806912021-03-24 A randomized noninferiority trial comparing the diagnostic yield of the 25G ProCore needle to the standard 25G needle in suspicious pancreatic lesions Hassan, Galab M. Wyse, Jonathan M. Paquin, Sarto C Gariepy, Gilles Albadine, Roula Mâsse, Benoît Trottier, Helen Sahai, Anand V. Endosc Ultrasound Original Article BACKGROUND AND OBJECTIVES: The aim of the study was to perform the first randomized trial comparing the diagnostic yield, bloodiness, and cellularity of the 25G standard needle (25S) and the 25G ProCore™ needle (25P). MATERIALS AND METHODS: All patients referred to the tertiary care referral center for EUS guided fine-needle aspiration (EUS-FNA) of suspicious solid pancreatic lesions were eligible. EUS-FNA was performed in each lesion with both 25S and 25P needles (the choice of the first needle was randomized), using a multipass sampling pattern, without stylet or suction. Rapid on-site evaluation was used when possible. Pap-stained slides were read by a single experienced cytopathologist, blinded to the needle type. RESULTS: One hundred and forty-three patients were recruited. Samples were positive for cancer in 122/143 (85.3%) with the 25S needle versus 126/143 (88.1%) with the 25P needle, negative in 17/143 (11.9%) with the 25S needle versus 13/143 (9.1%) with the 25P needle, and suspicious in 4/143 (2.8%) with each needle. There was no difference in any outcome based on the type of the first needle. No carryover effect was detected (P = 0.214; NS). Cumulative logistic regression analyses showed no associations between the type of needle and diagnostic yield for cancer, cellularity, or bloodiness. The difference in the yield for cancer was 2.9% (−4.2; 10.1%); with the confidence interval upper within the predetermined noninferiority margin of 15%. CONCLUSION: The 25S needle is noninferior to the 25P needle for diagnosing cancer in suspicious pancreatic lesions. Wolters Kluwer - Medknow 2021-01-05 /pmc/articles/PMC7980691/ /pubmed/33402551 http://dx.doi.org/10.4103/eus.eus_69_20 Text en Copyright: © 2021 SPRING MEDIA PUBLISHING CO. LTD http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Hassan, Galab M.
Wyse, Jonathan M.
Paquin, Sarto C
Gariepy, Gilles
Albadine, Roula
Mâsse, Benoît
Trottier, Helen
Sahai, Anand V.
A randomized noninferiority trial comparing the diagnostic yield of the 25G ProCore needle to the standard 25G needle in suspicious pancreatic lesions
title A randomized noninferiority trial comparing the diagnostic yield of the 25G ProCore needle to the standard 25G needle in suspicious pancreatic lesions
title_full A randomized noninferiority trial comparing the diagnostic yield of the 25G ProCore needle to the standard 25G needle in suspicious pancreatic lesions
title_fullStr A randomized noninferiority trial comparing the diagnostic yield of the 25G ProCore needle to the standard 25G needle in suspicious pancreatic lesions
title_full_unstemmed A randomized noninferiority trial comparing the diagnostic yield of the 25G ProCore needle to the standard 25G needle in suspicious pancreatic lesions
title_short A randomized noninferiority trial comparing the diagnostic yield of the 25G ProCore needle to the standard 25G needle in suspicious pancreatic lesions
title_sort randomized noninferiority trial comparing the diagnostic yield of the 25g procore needle to the standard 25g needle in suspicious pancreatic lesions
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7980691/
https://www.ncbi.nlm.nih.gov/pubmed/33402551
http://dx.doi.org/10.4103/eus.eus_69_20
work_keys_str_mv AT hassangalabm arandomizednoninferioritytrialcomparingthediagnosticyieldofthe25gprocoreneedletothestandard25gneedleinsuspiciouspancreaticlesions
AT wysejonathanm arandomizednoninferioritytrialcomparingthediagnosticyieldofthe25gprocoreneedletothestandard25gneedleinsuspiciouspancreaticlesions
AT paquinsartoc arandomizednoninferioritytrialcomparingthediagnosticyieldofthe25gprocoreneedletothestandard25gneedleinsuspiciouspancreaticlesions
AT gariepygilles arandomizednoninferioritytrialcomparingthediagnosticyieldofthe25gprocoreneedletothestandard25gneedleinsuspiciouspancreaticlesions
AT albadineroula arandomizednoninferioritytrialcomparingthediagnosticyieldofthe25gprocoreneedletothestandard25gneedleinsuspiciouspancreaticlesions
AT massebenoit arandomizednoninferioritytrialcomparingthediagnosticyieldofthe25gprocoreneedletothestandard25gneedleinsuspiciouspancreaticlesions
AT trottierhelen arandomizednoninferioritytrialcomparingthediagnosticyieldofthe25gprocoreneedletothestandard25gneedleinsuspiciouspancreaticlesions
AT sahaianandv arandomizednoninferioritytrialcomparingthediagnosticyieldofthe25gprocoreneedletothestandard25gneedleinsuspiciouspancreaticlesions
AT hassangalabm randomizednoninferioritytrialcomparingthediagnosticyieldofthe25gprocoreneedletothestandard25gneedleinsuspiciouspancreaticlesions
AT wysejonathanm randomizednoninferioritytrialcomparingthediagnosticyieldofthe25gprocoreneedletothestandard25gneedleinsuspiciouspancreaticlesions
AT paquinsartoc randomizednoninferioritytrialcomparingthediagnosticyieldofthe25gprocoreneedletothestandard25gneedleinsuspiciouspancreaticlesions
AT gariepygilles randomizednoninferioritytrialcomparingthediagnosticyieldofthe25gprocoreneedletothestandard25gneedleinsuspiciouspancreaticlesions
AT albadineroula randomizednoninferioritytrialcomparingthediagnosticyieldofthe25gprocoreneedletothestandard25gneedleinsuspiciouspancreaticlesions
AT massebenoit randomizednoninferioritytrialcomparingthediagnosticyieldofthe25gprocoreneedletothestandard25gneedleinsuspiciouspancreaticlesions
AT trottierhelen randomizednoninferioritytrialcomparingthediagnosticyieldofthe25gprocoreneedletothestandard25gneedleinsuspiciouspancreaticlesions
AT sahaianandv randomizednoninferioritytrialcomparingthediagnosticyieldofthe25gprocoreneedletothestandard25gneedleinsuspiciouspancreaticlesions