Cargando…
Diagnostic accuracy of semiquantitative point of care urine albumin to creatinine ratio and urine dipstick analysis in a primary care resource limited setting in South Africa
BACKGROUND: The prevalence of chronic kidney disease (CKD) is predicted to rise over the next few decades. In resource-limited settings access to central laboratory services is limited. Point-of-care (POC) urine dipstick testing offers the potential to detect markers of kidney damage (albuminuria) a...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7981803/ https://www.ncbi.nlm.nih.gov/pubmed/33743616 http://dx.doi.org/10.1186/s12882-021-02290-5 |
_version_ | 1783667589371658240 |
---|---|
author | Currin, Sean D. Gondwe, Mwawi S. Mayindi, Nokthula B. Chipungu, Shingirai Khoza, Bongekile L. Tollman, Stephen Fabian, June George, Jaya A. |
author_facet | Currin, Sean D. Gondwe, Mwawi S. Mayindi, Nokthula B. Chipungu, Shingirai Khoza, Bongekile L. Tollman, Stephen Fabian, June George, Jaya A. |
author_sort | Currin, Sean D. |
collection | PubMed |
description | BACKGROUND: The prevalence of chronic kidney disease (CKD) is predicted to rise over the next few decades. In resource-limited settings access to central laboratory services is limited. Point-of-care (POC) urine dipstick testing offers the potential to detect markers of kidney damage (albuminuria) as well as markers of other disease processes. We evaluated the diagnostic accuracy of the semi-quantitative albumin-creatinine ratio (ACR) Sysmex UC-1000 POC urine dipstick system as well as the extent of other abnormal dipstick findings in urine. METHODS: 700 participants from a rural area in South Africa were screened for albuminuria. A spot urine sample was used to measure POC and central laboratory ACR. We determined the sensitivity, specificity, positive predictive value and negative predictive value of the POC ACR, and recorded dipstick parameters. RESULTS: The prevalence of albuminuria was 11.6% (95%CI; 9.3–14.2). Those with albuminuria had higher mean diastolic (82 vs 79 mmHg, p = 0.019) and systolic (133 vs 128 mmHg, p = 0.002) blood pressures and a higher proportion of diabetes mellitus (17.6 vs 4.9%, p < 0.001). The sensitivity of the POC ACR system was 0.79, specificity 0.84, positive predictive value 0.39 and negative predictive value 0.97. The sensitivity improved to 0.80, 0.85, 0.85 and 0.89 in those with elevated blood pressure, diabetes mellitus, HIV positive status, and those 65 years and older, respectively. Abnormalities other than albuminuria were detected in 240 (34.3%) of the samples; 88 (12.6%) were positive for haematuria, 113 (16.1%) for leucocytes, 66 (9.4%) for nitrites and 27 (3.9%) for glycosuria. CONCLUSION: Our study shows that POC ACR has good negative predictive value and could be used to rule out albuminuria when screening for CKD. Additionally, a high proportion of participants had other urine abnormalities detected with dipsticks which may reflect kidney disease or co-morbid untreated genitourinary pathology such as urinary tract infections or endemic schistosomiasis with important implications for CKD. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12882-021-02290-5. |
format | Online Article Text |
id | pubmed-7981803 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-79818032021-03-22 Diagnostic accuracy of semiquantitative point of care urine albumin to creatinine ratio and urine dipstick analysis in a primary care resource limited setting in South Africa Currin, Sean D. Gondwe, Mwawi S. Mayindi, Nokthula B. Chipungu, Shingirai Khoza, Bongekile L. Tollman, Stephen Fabian, June George, Jaya A. BMC Nephrol Research Article BACKGROUND: The prevalence of chronic kidney disease (CKD) is predicted to rise over the next few decades. In resource-limited settings access to central laboratory services is limited. Point-of-care (POC) urine dipstick testing offers the potential to detect markers of kidney damage (albuminuria) as well as markers of other disease processes. We evaluated the diagnostic accuracy of the semi-quantitative albumin-creatinine ratio (ACR) Sysmex UC-1000 POC urine dipstick system as well as the extent of other abnormal dipstick findings in urine. METHODS: 700 participants from a rural area in South Africa were screened for albuminuria. A spot urine sample was used to measure POC and central laboratory ACR. We determined the sensitivity, specificity, positive predictive value and negative predictive value of the POC ACR, and recorded dipstick parameters. RESULTS: The prevalence of albuminuria was 11.6% (95%CI; 9.3–14.2). Those with albuminuria had higher mean diastolic (82 vs 79 mmHg, p = 0.019) and systolic (133 vs 128 mmHg, p = 0.002) blood pressures and a higher proportion of diabetes mellitus (17.6 vs 4.9%, p < 0.001). The sensitivity of the POC ACR system was 0.79, specificity 0.84, positive predictive value 0.39 and negative predictive value 0.97. The sensitivity improved to 0.80, 0.85, 0.85 and 0.89 in those with elevated blood pressure, diabetes mellitus, HIV positive status, and those 65 years and older, respectively. Abnormalities other than albuminuria were detected in 240 (34.3%) of the samples; 88 (12.6%) were positive for haematuria, 113 (16.1%) for leucocytes, 66 (9.4%) for nitrites and 27 (3.9%) for glycosuria. CONCLUSION: Our study shows that POC ACR has good negative predictive value and could be used to rule out albuminuria when screening for CKD. Additionally, a high proportion of participants had other urine abnormalities detected with dipsticks which may reflect kidney disease or co-morbid untreated genitourinary pathology such as urinary tract infections or endemic schistosomiasis with important implications for CKD. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12882-021-02290-5. BioMed Central 2021-03-20 /pmc/articles/PMC7981803/ /pubmed/33743616 http://dx.doi.org/10.1186/s12882-021-02290-5 Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Currin, Sean D. Gondwe, Mwawi S. Mayindi, Nokthula B. Chipungu, Shingirai Khoza, Bongekile L. Tollman, Stephen Fabian, June George, Jaya A. Diagnostic accuracy of semiquantitative point of care urine albumin to creatinine ratio and urine dipstick analysis in a primary care resource limited setting in South Africa |
title | Diagnostic accuracy of semiquantitative point of care urine albumin to creatinine ratio and urine dipstick analysis in a primary care resource limited setting in South Africa |
title_full | Diagnostic accuracy of semiquantitative point of care urine albumin to creatinine ratio and urine dipstick analysis in a primary care resource limited setting in South Africa |
title_fullStr | Diagnostic accuracy of semiquantitative point of care urine albumin to creatinine ratio and urine dipstick analysis in a primary care resource limited setting in South Africa |
title_full_unstemmed | Diagnostic accuracy of semiquantitative point of care urine albumin to creatinine ratio and urine dipstick analysis in a primary care resource limited setting in South Africa |
title_short | Diagnostic accuracy of semiquantitative point of care urine albumin to creatinine ratio and urine dipstick analysis in a primary care resource limited setting in South Africa |
title_sort | diagnostic accuracy of semiquantitative point of care urine albumin to creatinine ratio and urine dipstick analysis in a primary care resource limited setting in south africa |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7981803/ https://www.ncbi.nlm.nih.gov/pubmed/33743616 http://dx.doi.org/10.1186/s12882-021-02290-5 |
work_keys_str_mv | AT currinseand diagnosticaccuracyofsemiquantitativepointofcareurinealbumintocreatinineratioandurinedipstickanalysisinaprimarycareresourcelimitedsettinginsouthafrica AT gondwemwawis diagnosticaccuracyofsemiquantitativepointofcareurinealbumintocreatinineratioandurinedipstickanalysisinaprimarycareresourcelimitedsettinginsouthafrica AT mayindinokthulab diagnosticaccuracyofsemiquantitativepointofcareurinealbumintocreatinineratioandurinedipstickanalysisinaprimarycareresourcelimitedsettinginsouthafrica AT chipungushingirai diagnosticaccuracyofsemiquantitativepointofcareurinealbumintocreatinineratioandurinedipstickanalysisinaprimarycareresourcelimitedsettinginsouthafrica AT khozabongekilel diagnosticaccuracyofsemiquantitativepointofcareurinealbumintocreatinineratioandurinedipstickanalysisinaprimarycareresourcelimitedsettinginsouthafrica AT tollmanstephen diagnosticaccuracyofsemiquantitativepointofcareurinealbumintocreatinineratioandurinedipstickanalysisinaprimarycareresourcelimitedsettinginsouthafrica AT fabianjune diagnosticaccuracyofsemiquantitativepointofcareurinealbumintocreatinineratioandurinedipstickanalysisinaprimarycareresourcelimitedsettinginsouthafrica AT georgejayaa diagnosticaccuracyofsemiquantitativepointofcareurinealbumintocreatinineratioandurinedipstickanalysisinaprimarycareresourcelimitedsettinginsouthafrica AT diagnosticaccuracyofsemiquantitativepointofcareurinealbumintocreatinineratioandurinedipstickanalysisinaprimarycareresourcelimitedsettinginsouthafrica |