Correlation of Automated Chemiluminescent Method with Enzyme-Linked Immunosorbent Assay (ELISA) Antibody Titers in Convalescent COVID-19 Plasma Samples: Development of Rapid, Cost-Effective Semi-Quantitative Diagnostic Methods
BACKGROUND: We investigated the utility of an automated chemiluminescent SARS-CoV-2 IgG antibody assay platform in quantifying the amount of binding antibodies present in donated convalescent plasma. METHODS: A total of 179 convalescent plasma units were analyzed for the presence of SARS-CoV-2 IgG a...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7982562/ https://www.ncbi.nlm.nih.gov/pubmed/33762863 http://dx.doi.org/10.2147/JBM.S296730 |
_version_ | 1783667745626259456 |
---|---|
author | Mendoza, Rachelle Silver, Michael Zuretti, Alejandro R Christian, Manan Das, Ballabh Norin, Allen J Borgen, Patrick Libien, Jenny Bluth, Martin H |
author_facet | Mendoza, Rachelle Silver, Michael Zuretti, Alejandro R Christian, Manan Das, Ballabh Norin, Allen J Borgen, Patrick Libien, Jenny Bluth, Martin H |
author_sort | Mendoza, Rachelle |
collection | PubMed |
description | BACKGROUND: We investigated the utility of an automated chemiluminescent SARS-CoV-2 IgG antibody assay platform in quantifying the amount of binding antibodies present in donated convalescent plasma. METHODS: A total of 179 convalescent plasma units were analyzed for the presence of SARS-CoV-2 IgG antibodies using the Beckman-Coulter chemiluminescent immunoassay (CLIA) platform. The equipment-derived numerical values (S/Co ratio) were recorded. Aliquots from the same units were subjected to enzyme-linked immunosorbent assay (ELISA) that detects IgG antibodies against the receptor-binding domain (RBD) of the SARS-CoV-2 S1 protein. The relationship between ELISA titers and CLIA S/Co values was analyzed using linear regression and receiver operating characteristics (ROC) curve. RESULTS: Twenty-one samples (11.7%) had S/Co values of less than 1.0 and were deemed negative for antibodies and convalescent plasma had S/Co values between >1.0 and 5.0 (70/179, 39.1%). Fifteen units (8.4%) had negative ELISA titer. The majority of the units (95/179. 53.1%) had titers ≥1:1024. The sensitivities of ELISA to CLIA were comparable (90.5% vs 88.3%, respectively; p=0.18). There was positive linear correlation between CLIA S/Co values and ELISA IgG titer (Rho = 0.75; Spearman’s rank = 0.82, p-value = <0.0001). The agreement between the two methods was fair, with a κ index of 0.2741. Using the ROC analysis, we identified a CLIA S/Co cutoff value of 8.2, which gives a sensitivity of 90% and a specificity of 82% in predicting a titer dilution of ≥1:1024. CONCLUSION: The utility of automated antibody detection systems can be extended from simply a screening method to a semi-quantitative and quantitative functional antibody analysis. CLIA S/Co values can be used to reliably estimate the ELISA antibody titer. Incorporation of chemiluminescent-based methods can provide rapid, cost-effective means of identifying anti-SARS-CoV-2 antibody titers in donated plasma for use in the treatment of COVID-19 infection. |
format | Online Article Text |
id | pubmed-7982562 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-79825622021-03-23 Correlation of Automated Chemiluminescent Method with Enzyme-Linked Immunosorbent Assay (ELISA) Antibody Titers in Convalescent COVID-19 Plasma Samples: Development of Rapid, Cost-Effective Semi-Quantitative Diagnostic Methods Mendoza, Rachelle Silver, Michael Zuretti, Alejandro R Christian, Manan Das, Ballabh Norin, Allen J Borgen, Patrick Libien, Jenny Bluth, Martin H J Blood Med Methodology BACKGROUND: We investigated the utility of an automated chemiluminescent SARS-CoV-2 IgG antibody assay platform in quantifying the amount of binding antibodies present in donated convalescent plasma. METHODS: A total of 179 convalescent plasma units were analyzed for the presence of SARS-CoV-2 IgG antibodies using the Beckman-Coulter chemiluminescent immunoassay (CLIA) platform. The equipment-derived numerical values (S/Co ratio) were recorded. Aliquots from the same units were subjected to enzyme-linked immunosorbent assay (ELISA) that detects IgG antibodies against the receptor-binding domain (RBD) of the SARS-CoV-2 S1 protein. The relationship between ELISA titers and CLIA S/Co values was analyzed using linear regression and receiver operating characteristics (ROC) curve. RESULTS: Twenty-one samples (11.7%) had S/Co values of less than 1.0 and were deemed negative for antibodies and convalescent plasma had S/Co values between >1.0 and 5.0 (70/179, 39.1%). Fifteen units (8.4%) had negative ELISA titer. The majority of the units (95/179. 53.1%) had titers ≥1:1024. The sensitivities of ELISA to CLIA were comparable (90.5% vs 88.3%, respectively; p=0.18). There was positive linear correlation between CLIA S/Co values and ELISA IgG titer (Rho = 0.75; Spearman’s rank = 0.82, p-value = <0.0001). The agreement between the two methods was fair, with a κ index of 0.2741. Using the ROC analysis, we identified a CLIA S/Co cutoff value of 8.2, which gives a sensitivity of 90% and a specificity of 82% in predicting a titer dilution of ≥1:1024. CONCLUSION: The utility of automated antibody detection systems can be extended from simply a screening method to a semi-quantitative and quantitative functional antibody analysis. CLIA S/Co values can be used to reliably estimate the ELISA antibody titer. Incorporation of chemiluminescent-based methods can provide rapid, cost-effective means of identifying anti-SARS-CoV-2 antibody titers in donated plasma for use in the treatment of COVID-19 infection. Dove 2021-03-17 /pmc/articles/PMC7982562/ /pubmed/33762863 http://dx.doi.org/10.2147/JBM.S296730 Text en © 2021 Mendoza et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Methodology Mendoza, Rachelle Silver, Michael Zuretti, Alejandro R Christian, Manan Das, Ballabh Norin, Allen J Borgen, Patrick Libien, Jenny Bluth, Martin H Correlation of Automated Chemiluminescent Method with Enzyme-Linked Immunosorbent Assay (ELISA) Antibody Titers in Convalescent COVID-19 Plasma Samples: Development of Rapid, Cost-Effective Semi-Quantitative Diagnostic Methods |
title | Correlation of Automated Chemiluminescent Method with Enzyme-Linked Immunosorbent Assay (ELISA) Antibody Titers in Convalescent COVID-19 Plasma Samples: Development of Rapid, Cost-Effective Semi-Quantitative Diagnostic Methods |
title_full | Correlation of Automated Chemiluminescent Method with Enzyme-Linked Immunosorbent Assay (ELISA) Antibody Titers in Convalescent COVID-19 Plasma Samples: Development of Rapid, Cost-Effective Semi-Quantitative Diagnostic Methods |
title_fullStr | Correlation of Automated Chemiluminescent Method with Enzyme-Linked Immunosorbent Assay (ELISA) Antibody Titers in Convalescent COVID-19 Plasma Samples: Development of Rapid, Cost-Effective Semi-Quantitative Diagnostic Methods |
title_full_unstemmed | Correlation of Automated Chemiluminescent Method with Enzyme-Linked Immunosorbent Assay (ELISA) Antibody Titers in Convalescent COVID-19 Plasma Samples: Development of Rapid, Cost-Effective Semi-Quantitative Diagnostic Methods |
title_short | Correlation of Automated Chemiluminescent Method with Enzyme-Linked Immunosorbent Assay (ELISA) Antibody Titers in Convalescent COVID-19 Plasma Samples: Development of Rapid, Cost-Effective Semi-Quantitative Diagnostic Methods |
title_sort | correlation of automated chemiluminescent method with enzyme-linked immunosorbent assay (elisa) antibody titers in convalescent covid-19 plasma samples: development of rapid, cost-effective semi-quantitative diagnostic methods |
topic | Methodology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7982562/ https://www.ncbi.nlm.nih.gov/pubmed/33762863 http://dx.doi.org/10.2147/JBM.S296730 |
work_keys_str_mv | AT mendozarachelle correlationofautomatedchemiluminescentmethodwithenzymelinkedimmunosorbentassayelisaantibodytitersinconvalescentcovid19plasmasamplesdevelopmentofrapidcosteffectivesemiquantitativediagnosticmethods AT silvermichael correlationofautomatedchemiluminescentmethodwithenzymelinkedimmunosorbentassayelisaantibodytitersinconvalescentcovid19plasmasamplesdevelopmentofrapidcosteffectivesemiquantitativediagnosticmethods AT zurettialejandror correlationofautomatedchemiluminescentmethodwithenzymelinkedimmunosorbentassayelisaantibodytitersinconvalescentcovid19plasmasamplesdevelopmentofrapidcosteffectivesemiquantitativediagnosticmethods AT christianmanan correlationofautomatedchemiluminescentmethodwithenzymelinkedimmunosorbentassayelisaantibodytitersinconvalescentcovid19plasmasamplesdevelopmentofrapidcosteffectivesemiquantitativediagnosticmethods AT dasballabh correlationofautomatedchemiluminescentmethodwithenzymelinkedimmunosorbentassayelisaantibodytitersinconvalescentcovid19plasmasamplesdevelopmentofrapidcosteffectivesemiquantitativediagnosticmethods AT norinallenj correlationofautomatedchemiluminescentmethodwithenzymelinkedimmunosorbentassayelisaantibodytitersinconvalescentcovid19plasmasamplesdevelopmentofrapidcosteffectivesemiquantitativediagnosticmethods AT borgenpatrick correlationofautomatedchemiluminescentmethodwithenzymelinkedimmunosorbentassayelisaantibodytitersinconvalescentcovid19plasmasamplesdevelopmentofrapidcosteffectivesemiquantitativediagnosticmethods AT libienjenny correlationofautomatedchemiluminescentmethodwithenzymelinkedimmunosorbentassayelisaantibodytitersinconvalescentcovid19plasmasamplesdevelopmentofrapidcosteffectivesemiquantitativediagnosticmethods AT bluthmartinh correlationofautomatedchemiluminescentmethodwithenzymelinkedimmunosorbentassayelisaantibodytitersinconvalescentcovid19plasmasamplesdevelopmentofrapidcosteffectivesemiquantitativediagnosticmethods |