Cargando…
Acute Presentation of Structural Valve Degeneration in a Transcatheter Heart Valve (Sapien XT) at 7.5 Years; Successful Redo TAVR With a Sapien 3 Ultra
Little is known about the presentation of structural valve degeneration complicating transcatheter heart valves (THVs). We report a case of acute heart failure, secondary to leaflet prolapse, in a previously well 77-year-old man, 7.5 years after successful transcatheter aortic valve replacement with...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7984999/ https://www.ncbi.nlm.nih.gov/pubmed/33778458 http://dx.doi.org/10.1016/j.cjco.2020.11.007 |
_version_ | 1783668151306682368 |
---|---|
author | Doshi, Sagar N. Nadir, Adnan Moody, William Townend, Jonathan N. |
author_facet | Doshi, Sagar N. Nadir, Adnan Moody, William Townend, Jonathan N. |
author_sort | Doshi, Sagar N. |
collection | PubMed |
description | Little is known about the presentation of structural valve degeneration complicating transcatheter heart valves (THVs). We report a case of acute heart failure, secondary to leaflet prolapse, in a previously well 77-year-old man, 7.5 years after successful transcatheter aortic valve replacement with a 26-mm balloon-expandable Sapien XT (Edwards Lifesciences, Irvine, CA) THV. This case highlights that structural valve degeneration complicating THVs might lead to acute presentation with little warning from previous echocardiograms. Calcification might be absent on imaging. Redo transcatheter aortic valve replacement is feasible and appears safe. Post deployment optimization with a highly noncompliant balloon might improve full expansion of the newly implanted THV and improve valve performance. |
format | Online Article Text |
id | pubmed-7984999 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-79849992021-03-25 Acute Presentation of Structural Valve Degeneration in a Transcatheter Heart Valve (Sapien XT) at 7.5 Years; Successful Redo TAVR With a Sapien 3 Ultra Doshi, Sagar N. Nadir, Adnan Moody, William Townend, Jonathan N. CJC Open Case Report Little is known about the presentation of structural valve degeneration complicating transcatheter heart valves (THVs). We report a case of acute heart failure, secondary to leaflet prolapse, in a previously well 77-year-old man, 7.5 years after successful transcatheter aortic valve replacement with a 26-mm balloon-expandable Sapien XT (Edwards Lifesciences, Irvine, CA) THV. This case highlights that structural valve degeneration complicating THVs might lead to acute presentation with little warning from previous echocardiograms. Calcification might be absent on imaging. Redo transcatheter aortic valve replacement is feasible and appears safe. Post deployment optimization with a highly noncompliant balloon might improve full expansion of the newly implanted THV and improve valve performance. Elsevier 2020-11-17 /pmc/articles/PMC7984999/ /pubmed/33778458 http://dx.doi.org/10.1016/j.cjco.2020.11.007 Text en © 2020 Canadian Cardiovascular Society. Published by Elsevier Inc. http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Case Report Doshi, Sagar N. Nadir, Adnan Moody, William Townend, Jonathan N. Acute Presentation of Structural Valve Degeneration in a Transcatheter Heart Valve (Sapien XT) at 7.5 Years; Successful Redo TAVR With a Sapien 3 Ultra |
title | Acute Presentation of Structural Valve Degeneration in a Transcatheter Heart Valve (Sapien XT) at 7.5 Years; Successful Redo TAVR With a Sapien 3 Ultra |
title_full | Acute Presentation of Structural Valve Degeneration in a Transcatheter Heart Valve (Sapien XT) at 7.5 Years; Successful Redo TAVR With a Sapien 3 Ultra |
title_fullStr | Acute Presentation of Structural Valve Degeneration in a Transcatheter Heart Valve (Sapien XT) at 7.5 Years; Successful Redo TAVR With a Sapien 3 Ultra |
title_full_unstemmed | Acute Presentation of Structural Valve Degeneration in a Transcatheter Heart Valve (Sapien XT) at 7.5 Years; Successful Redo TAVR With a Sapien 3 Ultra |
title_short | Acute Presentation of Structural Valve Degeneration in a Transcatheter Heart Valve (Sapien XT) at 7.5 Years; Successful Redo TAVR With a Sapien 3 Ultra |
title_sort | acute presentation of structural valve degeneration in a transcatheter heart valve (sapien xt) at 7.5 years; successful redo tavr with a sapien 3 ultra |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7984999/ https://www.ncbi.nlm.nih.gov/pubmed/33778458 http://dx.doi.org/10.1016/j.cjco.2020.11.007 |
work_keys_str_mv | AT doshisagarn acutepresentationofstructuralvalvedegenerationinatranscatheterheartvalvesapienxtat75yearssuccessfulredotavrwithasapien3ultra AT nadiradnan acutepresentationofstructuralvalvedegenerationinatranscatheterheartvalvesapienxtat75yearssuccessfulredotavrwithasapien3ultra AT moodywilliam acutepresentationofstructuralvalvedegenerationinatranscatheterheartvalvesapienxtat75yearssuccessfulredotavrwithasapien3ultra AT townendjonathann acutepresentationofstructuralvalvedegenerationinatranscatheterheartvalvesapienxtat75yearssuccessfulredotavrwithasapien3ultra |