Cargando…

Reduced scan time and superior image quality with 3D flow MRI compared to 4D flow MRI for hemodynamic evaluation of the Fontan pathway

Long scan times prohibit a widespread clinical applicability of 4D flow MRI in Fontan patients. As pulsatility in the Fontan pathway is minimal during the cardiac cycle, acquiring non-ECG gated 3D flow MRI may result in a reduction of scan time while accurately obtaining time-averaged clinical param...

Descripción completa

Detalles Bibliográficos
Autores principales: Rijnberg, Friso M., van Assen, Hans C., Juffermans, Joe F., Kroft, Lucia J. M., van den Boogaard, Pieter J., de Koning, Patrick J. H., Hazekamp, Mark G., van der Woude, Séline F. S., Warmerdam, Evangeline G., Leiner, Tim, Grotenhuis, Heynric B., Goeman, Jelle J., Lamb, Hildo J., Roest, Arno A. W., Westenberg, Jos J. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7985309/
https://www.ncbi.nlm.nih.gov/pubmed/33753790
http://dx.doi.org/10.1038/s41598-021-85936-6
_version_ 1783668218378846208
author Rijnberg, Friso M.
van Assen, Hans C.
Juffermans, Joe F.
Kroft, Lucia J. M.
van den Boogaard, Pieter J.
de Koning, Patrick J. H.
Hazekamp, Mark G.
van der Woude, Séline F. S.
Warmerdam, Evangeline G.
Leiner, Tim
Grotenhuis, Heynric B.
Goeman, Jelle J.
Lamb, Hildo J.
Roest, Arno A. W.
Westenberg, Jos J. M.
author_facet Rijnberg, Friso M.
van Assen, Hans C.
Juffermans, Joe F.
Kroft, Lucia J. M.
van den Boogaard, Pieter J.
de Koning, Patrick J. H.
Hazekamp, Mark G.
van der Woude, Séline F. S.
Warmerdam, Evangeline G.
Leiner, Tim
Grotenhuis, Heynric B.
Goeman, Jelle J.
Lamb, Hildo J.
Roest, Arno A. W.
Westenberg, Jos J. M.
author_sort Rijnberg, Friso M.
collection PubMed
description Long scan times prohibit a widespread clinical applicability of 4D flow MRI in Fontan patients. As pulsatility in the Fontan pathway is minimal during the cardiac cycle, acquiring non-ECG gated 3D flow MRI may result in a reduction of scan time while accurately obtaining time-averaged clinical parameters in comparison with 2D and 4D flow MRI. Thirty-two Fontan patients prospectively underwent 2D (reference), 3D and 4D flow MRI of the Fontan pathway. Multiple clinical parameters were assessed from time-averaged flow rates, including the right-to-left pulmonary flow distribution (main endpoint) and systemic-to-pulmonary collateral flow (SPCF). A ten-fold reduction in scan time was achieved [4D flow 15.9 min (SD 2.7 min) and 3D flow 1.6 min (SD 7.8 s), p < 0.001] with a superior signal-to-noise ratio [mean ratio of SNRs 1.7 (0.8), p < 0.001] and vessel sharpness [mean ratio 1.2 (0.4), p = 0.01] with 3D flow. Compared to 2D flow, good–excellent agreement was shown for mean flow rates (ICC 0.82–0.96) and right-to-left pulmonary flow distribution (ICC 0.97). SPCF derived from 3D flow showed good agreement with that from 4D flow (ICC 0.86). 3D flow MRI allows for obtaining time-averaged flow rates and derived clinical parameters in the Fontan pathway with good–excellent agreement with 2D and 4D flow, but with a tenfold reduction in scan time and significantly improved image quality compared to 4D flow.
format Online
Article
Text
id pubmed-7985309
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-79853092021-03-25 Reduced scan time and superior image quality with 3D flow MRI compared to 4D flow MRI for hemodynamic evaluation of the Fontan pathway Rijnberg, Friso M. van Assen, Hans C. Juffermans, Joe F. Kroft, Lucia J. M. van den Boogaard, Pieter J. de Koning, Patrick J. H. Hazekamp, Mark G. van der Woude, Séline F. S. Warmerdam, Evangeline G. Leiner, Tim Grotenhuis, Heynric B. Goeman, Jelle J. Lamb, Hildo J. Roest, Arno A. W. Westenberg, Jos J. M. Sci Rep Article Long scan times prohibit a widespread clinical applicability of 4D flow MRI in Fontan patients. As pulsatility in the Fontan pathway is minimal during the cardiac cycle, acquiring non-ECG gated 3D flow MRI may result in a reduction of scan time while accurately obtaining time-averaged clinical parameters in comparison with 2D and 4D flow MRI. Thirty-two Fontan patients prospectively underwent 2D (reference), 3D and 4D flow MRI of the Fontan pathway. Multiple clinical parameters were assessed from time-averaged flow rates, including the right-to-left pulmonary flow distribution (main endpoint) and systemic-to-pulmonary collateral flow (SPCF). A ten-fold reduction in scan time was achieved [4D flow 15.9 min (SD 2.7 min) and 3D flow 1.6 min (SD 7.8 s), p < 0.001] with a superior signal-to-noise ratio [mean ratio of SNRs 1.7 (0.8), p < 0.001] and vessel sharpness [mean ratio 1.2 (0.4), p = 0.01] with 3D flow. Compared to 2D flow, good–excellent agreement was shown for mean flow rates (ICC 0.82–0.96) and right-to-left pulmonary flow distribution (ICC 0.97). SPCF derived from 3D flow showed good agreement with that from 4D flow (ICC 0.86). 3D flow MRI allows for obtaining time-averaged flow rates and derived clinical parameters in the Fontan pathway with good–excellent agreement with 2D and 4D flow, but with a tenfold reduction in scan time and significantly improved image quality compared to 4D flow. Nature Publishing Group UK 2021-03-22 /pmc/articles/PMC7985309/ /pubmed/33753790 http://dx.doi.org/10.1038/s41598-021-85936-6 Text en © The Author(s) 2021 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Rijnberg, Friso M.
van Assen, Hans C.
Juffermans, Joe F.
Kroft, Lucia J. M.
van den Boogaard, Pieter J.
de Koning, Patrick J. H.
Hazekamp, Mark G.
van der Woude, Séline F. S.
Warmerdam, Evangeline G.
Leiner, Tim
Grotenhuis, Heynric B.
Goeman, Jelle J.
Lamb, Hildo J.
Roest, Arno A. W.
Westenberg, Jos J. M.
Reduced scan time and superior image quality with 3D flow MRI compared to 4D flow MRI for hemodynamic evaluation of the Fontan pathway
title Reduced scan time and superior image quality with 3D flow MRI compared to 4D flow MRI for hemodynamic evaluation of the Fontan pathway
title_full Reduced scan time and superior image quality with 3D flow MRI compared to 4D flow MRI for hemodynamic evaluation of the Fontan pathway
title_fullStr Reduced scan time and superior image quality with 3D flow MRI compared to 4D flow MRI for hemodynamic evaluation of the Fontan pathway
title_full_unstemmed Reduced scan time and superior image quality with 3D flow MRI compared to 4D flow MRI for hemodynamic evaluation of the Fontan pathway
title_short Reduced scan time and superior image quality with 3D flow MRI compared to 4D flow MRI for hemodynamic evaluation of the Fontan pathway
title_sort reduced scan time and superior image quality with 3d flow mri compared to 4d flow mri for hemodynamic evaluation of the fontan pathway
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7985309/
https://www.ncbi.nlm.nih.gov/pubmed/33753790
http://dx.doi.org/10.1038/s41598-021-85936-6
work_keys_str_mv AT rijnbergfrisom reducedscantimeandsuperiorimagequalitywith3dflowmricomparedto4dflowmriforhemodynamicevaluationofthefontanpathway
AT vanassenhansc reducedscantimeandsuperiorimagequalitywith3dflowmricomparedto4dflowmriforhemodynamicevaluationofthefontanpathway
AT juffermansjoef reducedscantimeandsuperiorimagequalitywith3dflowmricomparedto4dflowmriforhemodynamicevaluationofthefontanpathway
AT kroftluciajm reducedscantimeandsuperiorimagequalitywith3dflowmricomparedto4dflowmriforhemodynamicevaluationofthefontanpathway
AT vandenboogaardpieterj reducedscantimeandsuperiorimagequalitywith3dflowmricomparedto4dflowmriforhemodynamicevaluationofthefontanpathway
AT dekoningpatrickjh reducedscantimeandsuperiorimagequalitywith3dflowmricomparedto4dflowmriforhemodynamicevaluationofthefontanpathway
AT hazekampmarkg reducedscantimeandsuperiorimagequalitywith3dflowmricomparedto4dflowmriforhemodynamicevaluationofthefontanpathway
AT vanderwoudeselinefs reducedscantimeandsuperiorimagequalitywith3dflowmricomparedto4dflowmriforhemodynamicevaluationofthefontanpathway
AT warmerdamevangelineg reducedscantimeandsuperiorimagequalitywith3dflowmricomparedto4dflowmriforhemodynamicevaluationofthefontanpathway
AT leinertim reducedscantimeandsuperiorimagequalitywith3dflowmricomparedto4dflowmriforhemodynamicevaluationofthefontanpathway
AT grotenhuisheynricb reducedscantimeandsuperiorimagequalitywith3dflowmricomparedto4dflowmriforhemodynamicevaluationofthefontanpathway
AT goemanjellej reducedscantimeandsuperiorimagequalitywith3dflowmricomparedto4dflowmriforhemodynamicevaluationofthefontanpathway
AT lambhildoj reducedscantimeandsuperiorimagequalitywith3dflowmricomparedto4dflowmriforhemodynamicevaluationofthefontanpathway
AT roestarnoaw reducedscantimeandsuperiorimagequalitywith3dflowmricomparedto4dflowmriforhemodynamicevaluationofthefontanpathway
AT westenbergjosjm reducedscantimeandsuperiorimagequalitywith3dflowmricomparedto4dflowmriforhemodynamicevaluationofthefontanpathway