Remote Continuous Glucose Monitoring With a Computerized Insulin Infusion Protocol for Critically Ill Patients in a COVID-19 Medical ICU: Proof of Concept
OBJECTIVE: The use of remote real-time continuous glucose monitoring (CGM) in the hospital has rapidly emerged to preserve personal protective equipment and reduce potential exposures during coronavirus disease 2019 (COVID-19). RESEARCH DESIGN AND METHODS: We linked a hybrid CGM and point-of-care (P...
Autores principales: | , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Diabetes Association
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7985417/ https://www.ncbi.nlm.nih.gov/pubmed/33563655 http://dx.doi.org/10.2337/dc20-2085 |
_version_ | 1783668242556911616 |
---|---|
author | Davis, Georgia M. Faulds, Eileen Walker, Tara Vigliotti, Debbie Rabinovich, Marina Hester, Joi Peng, Limin McLean, Barbara Hannon, Patricia Poindexter, Norma Saunders, Petrena Perez-Guzman, Citlalli Tekwani, Seema S. Martin, Greg S. Umpierrez, Guillermo Agarwal, Shivani Dungan, Kathleen Pasquel, Francisco J. |
author_facet | Davis, Georgia M. Faulds, Eileen Walker, Tara Vigliotti, Debbie Rabinovich, Marina Hester, Joi Peng, Limin McLean, Barbara Hannon, Patricia Poindexter, Norma Saunders, Petrena Perez-Guzman, Citlalli Tekwani, Seema S. Martin, Greg S. Umpierrez, Guillermo Agarwal, Shivani Dungan, Kathleen Pasquel, Francisco J. |
author_sort | Davis, Georgia M. |
collection | PubMed |
description | OBJECTIVE: The use of remote real-time continuous glucose monitoring (CGM) in the hospital has rapidly emerged to preserve personal protective equipment and reduce potential exposures during coronavirus disease 2019 (COVID-19). RESEARCH DESIGN AND METHODS: We linked a hybrid CGM and point-of-care (POC) glucose testing protocol to a computerized decision support system for continuous insulin infusion and integrated a validation system for sensor glucose values into the electronic health record. We report our proof-of-concept experience in a COVID-19 intensive care unit. RESULTS: All nine patients required mechanical ventilation and corticosteroids. During the protocol, 75.7% of sensor values were within 20% of the reference POC glucose with an associated average reduction in POC of 63%. Mean time in range (70–180 mg/dL) was 71.4 ± 13.9%. Sensor accuracy was impacted by mechanical interferences in four patients. CONCLUSIONS: A hybrid protocol integrating real-time CGM and POC is helpful for managing critically ill patients with COVID-19 requiring insulin infusion. |
format | Online Article Text |
id | pubmed-7985417 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | American Diabetes Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-79854172021-04-12 Remote Continuous Glucose Monitoring With a Computerized Insulin Infusion Protocol for Critically Ill Patients in a COVID-19 Medical ICU: Proof of Concept Davis, Georgia M. Faulds, Eileen Walker, Tara Vigliotti, Debbie Rabinovich, Marina Hester, Joi Peng, Limin McLean, Barbara Hannon, Patricia Poindexter, Norma Saunders, Petrena Perez-Guzman, Citlalli Tekwani, Seema S. Martin, Greg S. Umpierrez, Guillermo Agarwal, Shivani Dungan, Kathleen Pasquel, Francisco J. Diabetes Care Novel Communications in Diabetes OBJECTIVE: The use of remote real-time continuous glucose monitoring (CGM) in the hospital has rapidly emerged to preserve personal protective equipment and reduce potential exposures during coronavirus disease 2019 (COVID-19). RESEARCH DESIGN AND METHODS: We linked a hybrid CGM and point-of-care (POC) glucose testing protocol to a computerized decision support system for continuous insulin infusion and integrated a validation system for sensor glucose values into the electronic health record. We report our proof-of-concept experience in a COVID-19 intensive care unit. RESULTS: All nine patients required mechanical ventilation and corticosteroids. During the protocol, 75.7% of sensor values were within 20% of the reference POC glucose with an associated average reduction in POC of 63%. Mean time in range (70–180 mg/dL) was 71.4 ± 13.9%. Sensor accuracy was impacted by mechanical interferences in four patients. CONCLUSIONS: A hybrid protocol integrating real-time CGM and POC is helpful for managing critically ill patients with COVID-19 requiring insulin infusion. American Diabetes Association 2021-04 2021-02-09 /pmc/articles/PMC7985417/ /pubmed/33563655 http://dx.doi.org/10.2337/dc20-2085 Text en © 2021 by the American Diabetes Association https://www.diabetesjournals.org/content/licenseReaders may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered. More information is available at https://www.diabetesjournals.org/content/license. |
spellingShingle | Novel Communications in Diabetes Davis, Georgia M. Faulds, Eileen Walker, Tara Vigliotti, Debbie Rabinovich, Marina Hester, Joi Peng, Limin McLean, Barbara Hannon, Patricia Poindexter, Norma Saunders, Petrena Perez-Guzman, Citlalli Tekwani, Seema S. Martin, Greg S. Umpierrez, Guillermo Agarwal, Shivani Dungan, Kathleen Pasquel, Francisco J. Remote Continuous Glucose Monitoring With a Computerized Insulin Infusion Protocol for Critically Ill Patients in a COVID-19 Medical ICU: Proof of Concept |
title | Remote Continuous Glucose Monitoring With a Computerized Insulin Infusion Protocol for Critically Ill Patients in a COVID-19 Medical ICU: Proof of Concept |
title_full | Remote Continuous Glucose Monitoring With a Computerized Insulin Infusion Protocol for Critically Ill Patients in a COVID-19 Medical ICU: Proof of Concept |
title_fullStr | Remote Continuous Glucose Monitoring With a Computerized Insulin Infusion Protocol for Critically Ill Patients in a COVID-19 Medical ICU: Proof of Concept |
title_full_unstemmed | Remote Continuous Glucose Monitoring With a Computerized Insulin Infusion Protocol for Critically Ill Patients in a COVID-19 Medical ICU: Proof of Concept |
title_short | Remote Continuous Glucose Monitoring With a Computerized Insulin Infusion Protocol for Critically Ill Patients in a COVID-19 Medical ICU: Proof of Concept |
title_sort | remote continuous glucose monitoring with a computerized insulin infusion protocol for critically ill patients in a covid-19 medical icu: proof of concept |
topic | Novel Communications in Diabetes |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7985417/ https://www.ncbi.nlm.nih.gov/pubmed/33563655 http://dx.doi.org/10.2337/dc20-2085 |
work_keys_str_mv | AT davisgeorgiam remotecontinuousglucosemonitoringwithacomputerizedinsulininfusionprotocolforcriticallyillpatientsinacovid19medicalicuproofofconcept AT fauldseileen remotecontinuousglucosemonitoringwithacomputerizedinsulininfusionprotocolforcriticallyillpatientsinacovid19medicalicuproofofconcept AT walkertara remotecontinuousglucosemonitoringwithacomputerizedinsulininfusionprotocolforcriticallyillpatientsinacovid19medicalicuproofofconcept AT vigliottidebbie remotecontinuousglucosemonitoringwithacomputerizedinsulininfusionprotocolforcriticallyillpatientsinacovid19medicalicuproofofconcept AT rabinovichmarina remotecontinuousglucosemonitoringwithacomputerizedinsulininfusionprotocolforcriticallyillpatientsinacovid19medicalicuproofofconcept AT hesterjoi remotecontinuousglucosemonitoringwithacomputerizedinsulininfusionprotocolforcriticallyillpatientsinacovid19medicalicuproofofconcept AT penglimin remotecontinuousglucosemonitoringwithacomputerizedinsulininfusionprotocolforcriticallyillpatientsinacovid19medicalicuproofofconcept AT mcleanbarbara remotecontinuousglucosemonitoringwithacomputerizedinsulininfusionprotocolforcriticallyillpatientsinacovid19medicalicuproofofconcept AT hannonpatricia remotecontinuousglucosemonitoringwithacomputerizedinsulininfusionprotocolforcriticallyillpatientsinacovid19medicalicuproofofconcept AT poindexternorma remotecontinuousglucosemonitoringwithacomputerizedinsulininfusionprotocolforcriticallyillpatientsinacovid19medicalicuproofofconcept AT saunderspetrena remotecontinuousglucosemonitoringwithacomputerizedinsulininfusionprotocolforcriticallyillpatientsinacovid19medicalicuproofofconcept AT perezguzmancitlalli remotecontinuousglucosemonitoringwithacomputerizedinsulininfusionprotocolforcriticallyillpatientsinacovid19medicalicuproofofconcept AT tekwaniseemas remotecontinuousglucosemonitoringwithacomputerizedinsulininfusionprotocolforcriticallyillpatientsinacovid19medicalicuproofofconcept AT martingregs remotecontinuousglucosemonitoringwithacomputerizedinsulininfusionprotocolforcriticallyillpatientsinacovid19medicalicuproofofconcept AT umpierrezguillermo remotecontinuousglucosemonitoringwithacomputerizedinsulininfusionprotocolforcriticallyillpatientsinacovid19medicalicuproofofconcept AT agarwalshivani remotecontinuousglucosemonitoringwithacomputerizedinsulininfusionprotocolforcriticallyillpatientsinacovid19medicalicuproofofconcept AT dungankathleen remotecontinuousglucosemonitoringwithacomputerizedinsulininfusionprotocolforcriticallyillpatientsinacovid19medicalicuproofofconcept AT pasquelfranciscoj remotecontinuousglucosemonitoringwithacomputerizedinsulininfusionprotocolforcriticallyillpatientsinacovid19medicalicuproofofconcept |