Cargando…
An assessment of different electronic structure approaches for modeling time-resolved x-ray absorption spectroscopy
We assess the performance of different protocols for simulating excited-state x-ray absorption spectra. We consider three different protocols based on equation-of-motion coupled-cluster singles and doubles, two of them combined with the maximum overlap method. The three protocols differ in the choic...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Crystallographic Association
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7986275/ https://www.ncbi.nlm.nih.gov/pubmed/33786337 http://dx.doi.org/10.1063/4.0000070 |
_version_ | 1783668412506963968 |
---|---|
author | Tsuru, Shota Vidal, Marta L. Pápai, Mátyás Krylov, Anna I. Møller, Klaus B. Coriani, Sonia |
author_facet | Tsuru, Shota Vidal, Marta L. Pápai, Mátyás Krylov, Anna I. Møller, Klaus B. Coriani, Sonia |
author_sort | Tsuru, Shota |
collection | PubMed |
description | We assess the performance of different protocols for simulating excited-state x-ray absorption spectra. We consider three different protocols based on equation-of-motion coupled-cluster singles and doubles, two of them combined with the maximum overlap method. The three protocols differ in the choice of a reference configuration used to compute target states. Maximum-overlap-method time-dependent density functional theory is also considered. The performance of the different approaches is illustrated using uracil, thymine, and acetylacetone as benchmark systems. The results provide guidance for selecting an electronic structure method for modeling time-resolved x-ray absorption spectroscopy. |
format | Online Article Text |
id | pubmed-7986275 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | American Crystallographic Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-79862752021-03-29 An assessment of different electronic structure approaches for modeling time-resolved x-ray absorption spectroscopy Tsuru, Shota Vidal, Marta L. Pápai, Mátyás Krylov, Anna I. Møller, Klaus B. Coriani, Sonia Struct Dyn ARTICLES We assess the performance of different protocols for simulating excited-state x-ray absorption spectra. We consider three different protocols based on equation-of-motion coupled-cluster singles and doubles, two of them combined with the maximum overlap method. The three protocols differ in the choice of a reference configuration used to compute target states. Maximum-overlap-method time-dependent density functional theory is also considered. The performance of the different approaches is illustrated using uracil, thymine, and acetylacetone as benchmark systems. The results provide guidance for selecting an electronic structure method for modeling time-resolved x-ray absorption spectroscopy. American Crystallographic Association 2021-03-12 /pmc/articles/PMC7986275/ /pubmed/33786337 http://dx.doi.org/10.1063/4.0000070 Text en © 2021 Author(s). 2329-7778/2021/8(2)/024101/15 All article content, except where otherwise noted, is licensed under a Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | ARTICLES Tsuru, Shota Vidal, Marta L. Pápai, Mátyás Krylov, Anna I. Møller, Klaus B. Coriani, Sonia An assessment of different electronic structure approaches for modeling time-resolved x-ray absorption spectroscopy |
title | An assessment of different electronic structure approaches for modeling time-resolved x-ray absorption spectroscopy |
title_full | An assessment of different electronic structure approaches for modeling time-resolved x-ray absorption spectroscopy |
title_fullStr | An assessment of different electronic structure approaches for modeling time-resolved x-ray absorption spectroscopy |
title_full_unstemmed | An assessment of different electronic structure approaches for modeling time-resolved x-ray absorption spectroscopy |
title_short | An assessment of different electronic structure approaches for modeling time-resolved x-ray absorption spectroscopy |
title_sort | assessment of different electronic structure approaches for modeling time-resolved x-ray absorption spectroscopy |
topic | ARTICLES |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7986275/ https://www.ncbi.nlm.nih.gov/pubmed/33786337 http://dx.doi.org/10.1063/4.0000070 |
work_keys_str_mv | AT tsurushota anassessmentofdifferentelectronicstructureapproachesformodelingtimeresolvedxrayabsorptionspectroscopy AT vidalmartal anassessmentofdifferentelectronicstructureapproachesformodelingtimeresolvedxrayabsorptionspectroscopy AT papaimatyas anassessmentofdifferentelectronicstructureapproachesformodelingtimeresolvedxrayabsorptionspectroscopy AT krylovannai anassessmentofdifferentelectronicstructureapproachesformodelingtimeresolvedxrayabsorptionspectroscopy AT møllerklausb anassessmentofdifferentelectronicstructureapproachesformodelingtimeresolvedxrayabsorptionspectroscopy AT corianisonia anassessmentofdifferentelectronicstructureapproachesformodelingtimeresolvedxrayabsorptionspectroscopy AT tsurushota assessmentofdifferentelectronicstructureapproachesformodelingtimeresolvedxrayabsorptionspectroscopy AT vidalmartal assessmentofdifferentelectronicstructureapproachesformodelingtimeresolvedxrayabsorptionspectroscopy AT papaimatyas assessmentofdifferentelectronicstructureapproachesformodelingtimeresolvedxrayabsorptionspectroscopy AT krylovannai assessmentofdifferentelectronicstructureapproachesformodelingtimeresolvedxrayabsorptionspectroscopy AT møllerklausb assessmentofdifferentelectronicstructureapproachesformodelingtimeresolvedxrayabsorptionspectroscopy AT corianisonia assessmentofdifferentelectronicstructureapproachesformodelingtimeresolvedxrayabsorptionspectroscopy |