Computer‐assisted beam modeling for particle therapy

PURPOSE: To develop a computer‐driven and thus less user‐dependent method, allowing for a simple and straightforward generation of a Monte Carlo (MC) beam model of a scanned proton and carbon ion beam delivery system. METHODS: In a first step, experimental measurements were performed for proton and...

Descripción completa

Detalles Bibliográficos
Autores principales: Fuchs, Hermann, Elia, Alessio, Resch, Andreas F., Kuess, Peter, Lühr, Armin, Vidal, Marie, Grevillot, Loïc, Georg, Dietmar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7986420/
https://www.ncbi.nlm.nih.gov/pubmed/33283910
http://dx.doi.org/10.1002/mp.14647
_version_ 1783668441271500800
author Fuchs, Hermann
Elia, Alessio
Resch, Andreas F.
Kuess, Peter
Lühr, Armin
Vidal, Marie
Grevillot, Loïc
Georg, Dietmar
author_facet Fuchs, Hermann
Elia, Alessio
Resch, Andreas F.
Kuess, Peter
Lühr, Armin
Vidal, Marie
Grevillot, Loïc
Georg, Dietmar
author_sort Fuchs, Hermann
collection PubMed
description PURPOSE: To develop a computer‐driven and thus less user‐dependent method, allowing for a simple and straightforward generation of a Monte Carlo (MC) beam model of a scanned proton and carbon ion beam delivery system. METHODS: In a first step, experimental measurements were performed for proton and carbon ion energies in the available energy ranges. Data included depth dose profiles measured in water and spot sizes in air at various isocenter distances. Using an automated regularization‐based optimization process (AUTO‐BEAM), GATE/Geant4 beam models of the respective beam lines were generated. These were obtained sequentially by using least square weighting functions with and without regularization, to iteratively tune the beam parameters energy, energy spread, beam sigma, divergence, and emittance until a user‐defined agreement was reached. Based on the parameter tuning for a set of energies, a beam model was semi‐automatically generated. The resulting beam models were validated for all centers comparing to independent measurements of laterally integrated depth dose curves and spot sizes in air. For one representative center, three‐dimensional dose cubes were measured and compared to simulations. The method was applied on one research as well as four different clinical beam lines for proton and carbon ions of three different particle therapy centers using synchrotron or cyclotron accelerator systems: (a) MedAustron ion therapy center, (b) University Proton Therapy Dresden, and (c) Center Antoine Lacassagne Nice. RESULTS: Particle beam ranges in the MC beam models agreed on average within 0.2 mm compared to measurements for all energies and beam lines. Spot sizes in air (full‐width at half maximum) at all positions differed by less than 0.4% from the measurements. Dose calculation with the beam model for the clinical beam line at MedAustron agreed better than 1.7% in absolute dose for a representative clinical case treated with protons. For protons, beam model generation, including geometry creation, data conversion, and validation, was possible within three working days. The number of iterations required for the optimization process to converge, was found to be similar for all beam line geometries and particle types. CONCLUSION: The presented method was demonstrated to work independently of the beam optics behavior of the different beam lines, particle types, and geometries. Furthermore, it is suitable for non‐expert users and requires only limited user interaction. Beam model validation for different beam lines based on different beam delivery systems, showed good agreement.
format Online
Article
Text
id pubmed-7986420
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-79864202021-03-25 Computer‐assisted beam modeling for particle therapy Fuchs, Hermann Elia, Alessio Resch, Andreas F. Kuess, Peter Lühr, Armin Vidal, Marie Grevillot, Loïc Georg, Dietmar Med Phys COMPUTATIONAL AND EXPERIMENTAL DOSIMETRY PURPOSE: To develop a computer‐driven and thus less user‐dependent method, allowing for a simple and straightforward generation of a Monte Carlo (MC) beam model of a scanned proton and carbon ion beam delivery system. METHODS: In a first step, experimental measurements were performed for proton and carbon ion energies in the available energy ranges. Data included depth dose profiles measured in water and spot sizes in air at various isocenter distances. Using an automated regularization‐based optimization process (AUTO‐BEAM), GATE/Geant4 beam models of the respective beam lines were generated. These were obtained sequentially by using least square weighting functions with and without regularization, to iteratively tune the beam parameters energy, energy spread, beam sigma, divergence, and emittance until a user‐defined agreement was reached. Based on the parameter tuning for a set of energies, a beam model was semi‐automatically generated. The resulting beam models were validated for all centers comparing to independent measurements of laterally integrated depth dose curves and spot sizes in air. For one representative center, three‐dimensional dose cubes were measured and compared to simulations. The method was applied on one research as well as four different clinical beam lines for proton and carbon ions of three different particle therapy centers using synchrotron or cyclotron accelerator systems: (a) MedAustron ion therapy center, (b) University Proton Therapy Dresden, and (c) Center Antoine Lacassagne Nice. RESULTS: Particle beam ranges in the MC beam models agreed on average within 0.2 mm compared to measurements for all energies and beam lines. Spot sizes in air (full‐width at half maximum) at all positions differed by less than 0.4% from the measurements. Dose calculation with the beam model for the clinical beam line at MedAustron agreed better than 1.7% in absolute dose for a representative clinical case treated with protons. For protons, beam model generation, including geometry creation, data conversion, and validation, was possible within three working days. The number of iterations required for the optimization process to converge, was found to be similar for all beam line geometries and particle types. CONCLUSION: The presented method was demonstrated to work independently of the beam optics behavior of the different beam lines, particle types, and geometries. Furthermore, it is suitable for non‐expert users and requires only limited user interaction. Beam model validation for different beam lines based on different beam delivery systems, showed good agreement. John Wiley and Sons Inc. 2020-12-25 2021-02 /pmc/articles/PMC7986420/ /pubmed/33283910 http://dx.doi.org/10.1002/mp.14647 Text en © 2020 The Authors. Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle COMPUTATIONAL AND EXPERIMENTAL DOSIMETRY
Fuchs, Hermann
Elia, Alessio
Resch, Andreas F.
Kuess, Peter
Lühr, Armin
Vidal, Marie
Grevillot, Loïc
Georg, Dietmar
Computer‐assisted beam modeling for particle therapy
title Computer‐assisted beam modeling for particle therapy
title_full Computer‐assisted beam modeling for particle therapy
title_fullStr Computer‐assisted beam modeling for particle therapy
title_full_unstemmed Computer‐assisted beam modeling for particle therapy
title_short Computer‐assisted beam modeling for particle therapy
title_sort computer‐assisted beam modeling for particle therapy
topic COMPUTATIONAL AND EXPERIMENTAL DOSIMETRY
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7986420/
https://www.ncbi.nlm.nih.gov/pubmed/33283910
http://dx.doi.org/10.1002/mp.14647
work_keys_str_mv AT fuchshermann computerassistedbeammodelingforparticletherapy
AT eliaalessio computerassistedbeammodelingforparticletherapy
AT reschandreasf computerassistedbeammodelingforparticletherapy
AT kuesspeter computerassistedbeammodelingforparticletherapy
AT luhrarmin computerassistedbeammodelingforparticletherapy
AT vidalmarie computerassistedbeammodelingforparticletherapy
AT grevillotloic computerassistedbeammodelingforparticletherapy
AT georgdietmar computerassistedbeammodelingforparticletherapy