Cargando…
Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study
PURPOSE: To evaluate the clinical outcomes of cataract surgery with implantation of a novel model of extended depth of focus (EDOF) intraocular lens (IOL). METHODS: Pilot case series enrolling a total of 27 eyes of 16 patients (49 to 84 years) undergoing uncomplicated phacoemulsification cataract su...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7989957/ https://www.ncbi.nlm.nih.gov/pubmed/33776418 http://dx.doi.org/10.2147/OPTH.S297985 |
_version_ | 1783668994420506624 |
---|---|
author | Iradier, María T Cruz, Verónica Gentile, Naty Cedano, Priscila Piñero, David P |
author_facet | Iradier, María T Cruz, Verónica Gentile, Naty Cedano, Priscila Piñero, David P |
author_sort | Iradier, María T |
collection | PubMed |
description | PURPOSE: To evaluate the clinical outcomes of cataract surgery with implantation of a novel model of extended depth of focus (EDOF) intraocular lens (IOL). METHODS: Pilot case series enrolling a total of 27 eyes of 16 patients (49 to 84 years) undergoing uncomplicated phacoemulsification cataract surgery with implantation of the EDOF IOL Synthesis PLUS (Cutting Edge, Montpellier, France). Near (UNVA, uncorrected near visual acuity; DCNVA, distance-corrected near visual acuity) and distance visual acuity (uncorrected and corrected distance visual acuity, UDVA and CDVA), monocular defocus curve and refractive outcomes were evaluated during a 3-month follow-up. RESULTS: Mean postoperative UDVA, UNVA and DCNVA were 0.11±0.17, 0.14±0.22 and 0.37±0.36 logMAR, respectively. A total of 84.6%, 91.7%, and 96.3% of eyes achieved postoperative UDVA, UNVA and CDVA of 0.20 logMAR or better. A total of 78.6% of eyes achieved postoperative DCNVA of 0.30 logMAR or better. Mean postoperative spherical equivalent was −0.76±0.53 D. The distance-corrected visual acuity was maintained on average over a value of 0.30 logMAR for the range of defocus levels between +1.00 and −1.50 D. CONCLUSION: The implantation of the Synthesis plus EDOF IOL after cataract surgery seems to provide functional levels of distance, intermediate and near visual acuity. The near visual performance with this new IOL might be significantly enhanced using a micro-monovision approach. The results of this pilot study should be confirmed in future clinical trials. |
format | Online Article Text |
id | pubmed-7989957 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-79899572021-03-25 Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study Iradier, María T Cruz, Verónica Gentile, Naty Cedano, Priscila Piñero, David P Clin Ophthalmol Original Research PURPOSE: To evaluate the clinical outcomes of cataract surgery with implantation of a novel model of extended depth of focus (EDOF) intraocular lens (IOL). METHODS: Pilot case series enrolling a total of 27 eyes of 16 patients (49 to 84 years) undergoing uncomplicated phacoemulsification cataract surgery with implantation of the EDOF IOL Synthesis PLUS (Cutting Edge, Montpellier, France). Near (UNVA, uncorrected near visual acuity; DCNVA, distance-corrected near visual acuity) and distance visual acuity (uncorrected and corrected distance visual acuity, UDVA and CDVA), monocular defocus curve and refractive outcomes were evaluated during a 3-month follow-up. RESULTS: Mean postoperative UDVA, UNVA and DCNVA were 0.11±0.17, 0.14±0.22 and 0.37±0.36 logMAR, respectively. A total of 84.6%, 91.7%, and 96.3% of eyes achieved postoperative UDVA, UNVA and CDVA of 0.20 logMAR or better. A total of 78.6% of eyes achieved postoperative DCNVA of 0.30 logMAR or better. Mean postoperative spherical equivalent was −0.76±0.53 D. The distance-corrected visual acuity was maintained on average over a value of 0.30 logMAR for the range of defocus levels between +1.00 and −1.50 D. CONCLUSION: The implantation of the Synthesis plus EDOF IOL after cataract surgery seems to provide functional levels of distance, intermediate and near visual acuity. The near visual performance with this new IOL might be significantly enhanced using a micro-monovision approach. The results of this pilot study should be confirmed in future clinical trials. Dove 2021-03-19 /pmc/articles/PMC7989957/ /pubmed/33776418 http://dx.doi.org/10.2147/OPTH.S297985 Text en © 2021 Iradier et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Iradier, María T Cruz, Verónica Gentile, Naty Cedano, Priscila Piñero, David P Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study |
title | Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study |
title_full | Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study |
title_fullStr | Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study |
title_full_unstemmed | Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study |
title_short | Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study |
title_sort | clinical outcomes with a novel extended depth of focus presbyopia-correcting intraocular lens: pilot study |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7989957/ https://www.ncbi.nlm.nih.gov/pubmed/33776418 http://dx.doi.org/10.2147/OPTH.S297985 |
work_keys_str_mv | AT iradiermariat clinicaloutcomeswithanovelextendeddepthoffocuspresbyopiacorrectingintraocularlenspilotstudy AT cruzveronica clinicaloutcomeswithanovelextendeddepthoffocuspresbyopiacorrectingintraocularlenspilotstudy AT gentilenaty clinicaloutcomeswithanovelextendeddepthoffocuspresbyopiacorrectingintraocularlenspilotstudy AT cedanopriscila clinicaloutcomeswithanovelextendeddepthoffocuspresbyopiacorrectingintraocularlenspilotstudy AT pinerodavidp clinicaloutcomeswithanovelextendeddepthoffocuspresbyopiacorrectingintraocularlenspilotstudy |