Cargando…

Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study

PURPOSE: To evaluate the clinical outcomes of cataract surgery with implantation of a novel model of extended depth of focus (EDOF) intraocular lens (IOL). METHODS: Pilot case series enrolling a total of 27 eyes of 16 patients (49 to 84 years) undergoing uncomplicated phacoemulsification cataract su...

Descripción completa

Detalles Bibliográficos
Autores principales: Iradier, María T, Cruz, Verónica, Gentile, Naty, Cedano, Priscila, Piñero, David P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7989957/
https://www.ncbi.nlm.nih.gov/pubmed/33776418
http://dx.doi.org/10.2147/OPTH.S297985
_version_ 1783668994420506624
author Iradier, María T
Cruz, Verónica
Gentile, Naty
Cedano, Priscila
Piñero, David P
author_facet Iradier, María T
Cruz, Verónica
Gentile, Naty
Cedano, Priscila
Piñero, David P
author_sort Iradier, María T
collection PubMed
description PURPOSE: To evaluate the clinical outcomes of cataract surgery with implantation of a novel model of extended depth of focus (EDOF) intraocular lens (IOL). METHODS: Pilot case series enrolling a total of 27 eyes of 16 patients (49 to 84 years) undergoing uncomplicated phacoemulsification cataract surgery with implantation of the EDOF IOL Synthesis PLUS (Cutting Edge, Montpellier, France). Near (UNVA, uncorrected near visual acuity; DCNVA, distance-corrected near visual acuity) and distance visual acuity (uncorrected and corrected distance visual acuity, UDVA and CDVA), monocular defocus curve and refractive outcomes were evaluated during a 3-month follow-up. RESULTS: Mean postoperative UDVA, UNVA and DCNVA were 0.11±0.17, 0.14±0.22 and 0.37±0.36 logMAR, respectively. A total of 84.6%, 91.7%, and 96.3% of eyes achieved postoperative UDVA, UNVA and CDVA of 0.20 logMAR or better. A total of 78.6% of eyes achieved postoperative DCNVA of 0.30 logMAR or better. Mean postoperative spherical equivalent was −0.76±0.53 D. The distance-corrected visual acuity was maintained on average over a value of 0.30 logMAR for the range of defocus levels between +1.00 and −1.50 D. CONCLUSION: The implantation of the Synthesis plus EDOF IOL after cataract surgery seems to provide functional levels of distance, intermediate and near visual acuity. The near visual performance with this new IOL might be significantly enhanced using a micro-monovision approach. The results of this pilot study should be confirmed in future clinical trials.
format Online
Article
Text
id pubmed-7989957
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-79899572021-03-25 Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study Iradier, María T Cruz, Verónica Gentile, Naty Cedano, Priscila Piñero, David P Clin Ophthalmol Original Research PURPOSE: To evaluate the clinical outcomes of cataract surgery with implantation of a novel model of extended depth of focus (EDOF) intraocular lens (IOL). METHODS: Pilot case series enrolling a total of 27 eyes of 16 patients (49 to 84 years) undergoing uncomplicated phacoemulsification cataract surgery with implantation of the EDOF IOL Synthesis PLUS (Cutting Edge, Montpellier, France). Near (UNVA, uncorrected near visual acuity; DCNVA, distance-corrected near visual acuity) and distance visual acuity (uncorrected and corrected distance visual acuity, UDVA and CDVA), monocular defocus curve and refractive outcomes were evaluated during a 3-month follow-up. RESULTS: Mean postoperative UDVA, UNVA and DCNVA were 0.11±0.17, 0.14±0.22 and 0.37±0.36 logMAR, respectively. A total of 84.6%, 91.7%, and 96.3% of eyes achieved postoperative UDVA, UNVA and CDVA of 0.20 logMAR or better. A total of 78.6% of eyes achieved postoperative DCNVA of 0.30 logMAR or better. Mean postoperative spherical equivalent was −0.76±0.53 D. The distance-corrected visual acuity was maintained on average over a value of 0.30 logMAR for the range of defocus levels between +1.00 and −1.50 D. CONCLUSION: The implantation of the Synthesis plus EDOF IOL after cataract surgery seems to provide functional levels of distance, intermediate and near visual acuity. The near visual performance with this new IOL might be significantly enhanced using a micro-monovision approach. The results of this pilot study should be confirmed in future clinical trials. Dove 2021-03-19 /pmc/articles/PMC7989957/ /pubmed/33776418 http://dx.doi.org/10.2147/OPTH.S297985 Text en © 2021 Iradier et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Iradier, María T
Cruz, Verónica
Gentile, Naty
Cedano, Priscila
Piñero, David P
Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study
title Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study
title_full Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study
title_fullStr Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study
title_full_unstemmed Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study
title_short Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study
title_sort clinical outcomes with a novel extended depth of focus presbyopia-correcting intraocular lens: pilot study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7989957/
https://www.ncbi.nlm.nih.gov/pubmed/33776418
http://dx.doi.org/10.2147/OPTH.S297985
work_keys_str_mv AT iradiermariat clinicaloutcomeswithanovelextendeddepthoffocuspresbyopiacorrectingintraocularlenspilotstudy
AT cruzveronica clinicaloutcomeswithanovelextendeddepthoffocuspresbyopiacorrectingintraocularlenspilotstudy
AT gentilenaty clinicaloutcomeswithanovelextendeddepthoffocuspresbyopiacorrectingintraocularlenspilotstudy
AT cedanopriscila clinicaloutcomeswithanovelextendeddepthoffocuspresbyopiacorrectingintraocularlenspilotstudy
AT pinerodavidp clinicaloutcomeswithanovelextendeddepthoffocuspresbyopiacorrectingintraocularlenspilotstudy