Liquid-Crystal Display (LCD) of achromatic, mean-modulated flicker in clinical assessment and experimental studies of visual systems

Achromatic, mean-modulated flicker—wherein luminance increments and decrements of equal magnitude are applied, over time, to a test field—is commonly used in both clinical assessment of vision and experimental studies of visual systems. However, presenting flicker on computer-controlled displays is...

Descripción completa

Detalles Bibliográficos
Autores principales: Hallum, Luke E., Cloherty, Shaun L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7990305/
https://www.ncbi.nlm.nih.gov/pubmed/33760857
http://dx.doi.org/10.1371/journal.pone.0248180
_version_ 1783669047186948096
author Hallum, Luke E.
Cloherty, Shaun L.
author_facet Hallum, Luke E.
Cloherty, Shaun L.
author_sort Hallum, Luke E.
collection PubMed
description Achromatic, mean-modulated flicker—wherein luminance increments and decrements of equal magnitude are applied, over time, to a test field—is commonly used in both clinical assessment of vision and experimental studies of visual systems. However, presenting flicker on computer-controlled displays is problematic; displays typically introduce luminance artifacts at high flicker frequency or contrast, potentially interfering with the validity of findings. Here, we present a battery of tests used to weigh the relative merits of two displays for presenting achromatic, mean-modulated flicker. These tests revealed marked differences between a new high-performance liquid-crystal display (LCD; EIZO ColorEdge CG247X) and a new consumer-grade LCD (Dell U2415b), despite displays’ vendor-supplied specifications being almost identical. We measured displayed luminance using a spot meter and a linearized photodiode. We derived several measures, including spatial uniformity, the effect of viewing angle, response times, Fourier amplitude spectra, and cycle-averaged luminance. We presented paired luminance pulses to quantify the displays’ nonlinear dynamics. The CG247X showed relatively good spatial uniformity (e.g., at moderate luminance, standard deviation 2.8% versus U2415b’s 5.3%). Fourier transformation of nominally static test patches revealed spectra free of artifacts, with the exception of a frame response. The CG247X’s rise and fall times depended on both the luminance from which, and to which, it responded, as is to be generally expected from LCDs. Despite this nonlinear behaviour, we were able to define a contrast and frequency range wherein the CG247X appeared largely artifact-free; the relationship between nominal luminance and displayed luminance was accurately modelled using a causal, linear time-invariant system. This range included contrasts up to 80%, and flicker frequencies up to 30 Hz. This battery of tests should prove useful to others conducting clinical assessment of vision and experimental studies of visual systems.
format Online
Article
Text
id pubmed-7990305
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-79903052021-04-05 Liquid-Crystal Display (LCD) of achromatic, mean-modulated flicker in clinical assessment and experimental studies of visual systems Hallum, Luke E. Cloherty, Shaun L. PLoS One Research Article Achromatic, mean-modulated flicker—wherein luminance increments and decrements of equal magnitude are applied, over time, to a test field—is commonly used in both clinical assessment of vision and experimental studies of visual systems. However, presenting flicker on computer-controlled displays is problematic; displays typically introduce luminance artifacts at high flicker frequency or contrast, potentially interfering with the validity of findings. Here, we present a battery of tests used to weigh the relative merits of two displays for presenting achromatic, mean-modulated flicker. These tests revealed marked differences between a new high-performance liquid-crystal display (LCD; EIZO ColorEdge CG247X) and a new consumer-grade LCD (Dell U2415b), despite displays’ vendor-supplied specifications being almost identical. We measured displayed luminance using a spot meter and a linearized photodiode. We derived several measures, including spatial uniformity, the effect of viewing angle, response times, Fourier amplitude spectra, and cycle-averaged luminance. We presented paired luminance pulses to quantify the displays’ nonlinear dynamics. The CG247X showed relatively good spatial uniformity (e.g., at moderate luminance, standard deviation 2.8% versus U2415b’s 5.3%). Fourier transformation of nominally static test patches revealed spectra free of artifacts, with the exception of a frame response. The CG247X’s rise and fall times depended on both the luminance from which, and to which, it responded, as is to be generally expected from LCDs. Despite this nonlinear behaviour, we were able to define a contrast and frequency range wherein the CG247X appeared largely artifact-free; the relationship between nominal luminance and displayed luminance was accurately modelled using a causal, linear time-invariant system. This range included contrasts up to 80%, and flicker frequencies up to 30 Hz. This battery of tests should prove useful to others conducting clinical assessment of vision and experimental studies of visual systems. Public Library of Science 2021-03-24 /pmc/articles/PMC7990305/ /pubmed/33760857 http://dx.doi.org/10.1371/journal.pone.0248180 Text en © 2021 Hallum, Cloherty http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Hallum, Luke E.
Cloherty, Shaun L.
Liquid-Crystal Display (LCD) of achromatic, mean-modulated flicker in clinical assessment and experimental studies of visual systems
title Liquid-Crystal Display (LCD) of achromatic, mean-modulated flicker in clinical assessment and experimental studies of visual systems
title_full Liquid-Crystal Display (LCD) of achromatic, mean-modulated flicker in clinical assessment and experimental studies of visual systems
title_fullStr Liquid-Crystal Display (LCD) of achromatic, mean-modulated flicker in clinical assessment and experimental studies of visual systems
title_full_unstemmed Liquid-Crystal Display (LCD) of achromatic, mean-modulated flicker in clinical assessment and experimental studies of visual systems
title_short Liquid-Crystal Display (LCD) of achromatic, mean-modulated flicker in clinical assessment and experimental studies of visual systems
title_sort liquid-crystal display (lcd) of achromatic, mean-modulated flicker in clinical assessment and experimental studies of visual systems
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7990305/
https://www.ncbi.nlm.nih.gov/pubmed/33760857
http://dx.doi.org/10.1371/journal.pone.0248180
work_keys_str_mv AT hallumlukee liquidcrystaldisplaylcdofachromaticmeanmodulatedflickerinclinicalassessmentandexperimentalstudiesofvisualsystems
AT clohertyshaunl liquidcrystaldisplaylcdofachromaticmeanmodulatedflickerinclinicalassessmentandexperimentalstudiesofvisualsystems