A Virtual Reality-Based Automated Perimeter, Device, and Pilot Study

PURPOSE: The purpose of this study was to describe a novel, virtual reality (VR)-based platform for evaluating visual fields. METHODS: Three subjects were tested on the VisuALL VR headset. Data collected included test duration per eye, total fixation losses (FLs), total false positives (FPs), and to...

Descripción completa

Detalles Bibliográficos
Autores principales: Montelongo, Mario, Gonzalez, Alberto, Morgenstern, Freddy, Donahue, Sean P., Groth, Sylvia L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7991920/
https://www.ncbi.nlm.nih.gov/pubmed/34003954
http://dx.doi.org/10.1167/tvst.10.3.20
_version_ 1783669271327408128
author Montelongo, Mario
Gonzalez, Alberto
Morgenstern, Freddy
Donahue, Sean P.
Groth, Sylvia L.
author_facet Montelongo, Mario
Gonzalez, Alberto
Morgenstern, Freddy
Donahue, Sean P.
Groth, Sylvia L.
author_sort Montelongo, Mario
collection PubMed
description PURPOSE: The purpose of this study was to describe a novel, virtual reality (VR)-based platform for evaluating visual fields. METHODS: Three subjects were tested on the VisuALL VR headset. Data collected included test duration per eye, total fixation losses (FLs), total false positives (FPs), and total false negatives (FNs). Mean threshold values were collected from the superior temporal (ST), superior nasal (SN), inferior nasal (IN), inferior temporal (IT) quadrants, and from the central 12 degrees (central), 12 to 24 degrees (pericentral), and from all testing loci (global). RESULTS: Six eyes of 3 subjects (2 men, 1 woman; mean age 30 years) were tested using the T-24 protocol (a Humphrey visual field [HVF] 24-2 equivalent). Mean test duration was 4.43 ± (SD) 0.11 minutes/eye. Mean threshold values ± SD for ST, SN, IN, IT, global, central, and pericentral were 31.1 ± 0.95 decibel (dB), 31.9 ± 0.3 dB, 32.0 ± 0.3 dB, 32.0 ± 1.1 dB, 31.9 ± 0.5 dB, 32.8 ± 0.5 dB, and 31.5 ± 0.5 dB, respectively. CONCLUSIONS: This work describes the technical aspects of the VisuALL. Participants were able to complete the test and generate threshold values at each of 50 locations in the central 24 degrees of visual field. This VR-based visual field test shows potential to become an alternative to analog, stationary standard automated perimetry tests. TRANSLATIONAL RELEVANCE: The VisuALL is an immersive, VR-based, automated perimeter that effectively addresses some of the limitations inherent to other popular perimetric devices. Potential advantages of the VisuALL are its adaptability, portability, and efficiency for patients. This device may be able to fill the gap present in at-home glaucoma monitoring and expand the reach of glaucoma management.
format Online
Article
Text
id pubmed-7991920
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-79919202021-03-30 A Virtual Reality-Based Automated Perimeter, Device, and Pilot Study Montelongo, Mario Gonzalez, Alberto Morgenstern, Freddy Donahue, Sean P. Groth, Sylvia L. Transl Vis Sci Technol Article PURPOSE: The purpose of this study was to describe a novel, virtual reality (VR)-based platform for evaluating visual fields. METHODS: Three subjects were tested on the VisuALL VR headset. Data collected included test duration per eye, total fixation losses (FLs), total false positives (FPs), and total false negatives (FNs). Mean threshold values were collected from the superior temporal (ST), superior nasal (SN), inferior nasal (IN), inferior temporal (IT) quadrants, and from the central 12 degrees (central), 12 to 24 degrees (pericentral), and from all testing loci (global). RESULTS: Six eyes of 3 subjects (2 men, 1 woman; mean age 30 years) were tested using the T-24 protocol (a Humphrey visual field [HVF] 24-2 equivalent). Mean test duration was 4.43 ± (SD) 0.11 minutes/eye. Mean threshold values ± SD for ST, SN, IN, IT, global, central, and pericentral were 31.1 ± 0.95 decibel (dB), 31.9 ± 0.3 dB, 32.0 ± 0.3 dB, 32.0 ± 1.1 dB, 31.9 ± 0.5 dB, 32.8 ± 0.5 dB, and 31.5 ± 0.5 dB, respectively. CONCLUSIONS: This work describes the technical aspects of the VisuALL. Participants were able to complete the test and generate threshold values at each of 50 locations in the central 24 degrees of visual field. This VR-based visual field test shows potential to become an alternative to analog, stationary standard automated perimetry tests. TRANSLATIONAL RELEVANCE: The VisuALL is an immersive, VR-based, automated perimeter that effectively addresses some of the limitations inherent to other popular perimetric devices. Potential advantages of the VisuALL are its adaptability, portability, and efficiency for patients. This device may be able to fill the gap present in at-home glaucoma monitoring and expand the reach of glaucoma management. The Association for Research in Vision and Ophthalmology 2021-03-22 /pmc/articles/PMC7991920/ /pubmed/34003954 http://dx.doi.org/10.1167/tvst.10.3.20 Text en Copyright 2021 The Authors http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License.
spellingShingle Article
Montelongo, Mario
Gonzalez, Alberto
Morgenstern, Freddy
Donahue, Sean P.
Groth, Sylvia L.
A Virtual Reality-Based Automated Perimeter, Device, and Pilot Study
title A Virtual Reality-Based Automated Perimeter, Device, and Pilot Study
title_full A Virtual Reality-Based Automated Perimeter, Device, and Pilot Study
title_fullStr A Virtual Reality-Based Automated Perimeter, Device, and Pilot Study
title_full_unstemmed A Virtual Reality-Based Automated Perimeter, Device, and Pilot Study
title_short A Virtual Reality-Based Automated Perimeter, Device, and Pilot Study
title_sort virtual reality-based automated perimeter, device, and pilot study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7991920/
https://www.ncbi.nlm.nih.gov/pubmed/34003954
http://dx.doi.org/10.1167/tvst.10.3.20
work_keys_str_mv AT montelongomario avirtualrealitybasedautomatedperimeterdeviceandpilotstudy
AT gonzalezalberto avirtualrealitybasedautomatedperimeterdeviceandpilotstudy
AT morgensternfreddy avirtualrealitybasedautomatedperimeterdeviceandpilotstudy
AT donahueseanp avirtualrealitybasedautomatedperimeterdeviceandpilotstudy
AT grothsylvial avirtualrealitybasedautomatedperimeterdeviceandpilotstudy
AT montelongomario virtualrealitybasedautomatedperimeterdeviceandpilotstudy
AT gonzalezalberto virtualrealitybasedautomatedperimeterdeviceandpilotstudy
AT morgensternfreddy virtualrealitybasedautomatedperimeterdeviceandpilotstudy
AT donahueseanp virtualrealitybasedautomatedperimeterdeviceandpilotstudy
AT grothsylvial virtualrealitybasedautomatedperimeterdeviceandpilotstudy