Cargando…

Measured Resection Techniques Do Not Align to the Cylindrical Axis in Kinematic Total Knee Arthroplasty

BACKGROUND: There has been increasing interest with improved functional results in kinematically aligned total knee arthroplasty. Kinematic alignment seeks to replicate the rotational axes of the individual knee. The femoral component can either be aligned to the estimated prearthritic distal and po...

Descripción completa

Detalles Bibliográficos
Autores principales: Drynan, David, Rasouli, Rabi Faisal, Williams, James W.A., Balalla, Buddhika
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7994728/
https://www.ncbi.nlm.nih.gov/pubmed/33786354
http://dx.doi.org/10.1016/j.artd.2021.02.014
_version_ 1783669815128358912
author Drynan, David
Rasouli, Rabi Faisal
Williams, James W.A.
Balalla, Buddhika
author_facet Drynan, David
Rasouli, Rabi Faisal
Williams, James W.A.
Balalla, Buddhika
author_sort Drynan, David
collection PubMed
description BACKGROUND: There has been increasing interest with improved functional results in kinematically aligned total knee arthroplasty. Kinematic alignment seeks to replicate the rotational axes of the individual knee. The femoral component can either be aligned to the estimated prearthritic distal and posterior joint lines via a measured-resection technique or by aligning to the cylindrical axis (CA). The CA is calculated using three-dimensional imaging and defined as a line equidistant from the medial and lateral condylar surfaces from 15° to 115° flexion. This study investigates whether these 2 techniques lead to similar alignment angles in the coronal plane. MATERIALS AND METHODS: One hundred three knees undergoing total knee arthroplasty were assessed using a computed tomography-based protocol. The image-based cylindrical axis coronal angle (CAA) was calculated, and the distal condylar coronal angle (DCA) was calculated to simulate a caliper measured resection technique. A computed tomographic planning software program was used to measure the offset from the distal-most extent of the calculated cylinder to the distal-most aspect of the condyles. RESULTS: The DCA measured 3.3° valgus (standard deviation 2.4°) and the CAA 1.8° valgus (standard deviation 2.1°). The mean difference in offset from CAA radius to DCA from the medial condyle and the lateral condyle was 2.85 mm and 1.51 mm, respectively, increasing valgus predilection. CONCLUSIONS: Caliper measured resection kinematically aligned techniques will position the femoral component in a significantly more valgus position than when aligning to the CA of the knee. This is due to an increased offset of the distal femoral articulation from the most distal aspect of the cylinder on the medial side of the knee.
format Online
Article
Text
id pubmed-7994728
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-79947282021-03-29 Measured Resection Techniques Do Not Align to the Cylindrical Axis in Kinematic Total Knee Arthroplasty Drynan, David Rasouli, Rabi Faisal Williams, James W.A. Balalla, Buddhika Arthroplast Today Original Research BACKGROUND: There has been increasing interest with improved functional results in kinematically aligned total knee arthroplasty. Kinematic alignment seeks to replicate the rotational axes of the individual knee. The femoral component can either be aligned to the estimated prearthritic distal and posterior joint lines via a measured-resection technique or by aligning to the cylindrical axis (CA). The CA is calculated using three-dimensional imaging and defined as a line equidistant from the medial and lateral condylar surfaces from 15° to 115° flexion. This study investigates whether these 2 techniques lead to similar alignment angles in the coronal plane. MATERIALS AND METHODS: One hundred three knees undergoing total knee arthroplasty were assessed using a computed tomography-based protocol. The image-based cylindrical axis coronal angle (CAA) was calculated, and the distal condylar coronal angle (DCA) was calculated to simulate a caliper measured resection technique. A computed tomographic planning software program was used to measure the offset from the distal-most extent of the calculated cylinder to the distal-most aspect of the condyles. RESULTS: The DCA measured 3.3° valgus (standard deviation 2.4°) and the CAA 1.8° valgus (standard deviation 2.1°). The mean difference in offset from CAA radius to DCA from the medial condyle and the lateral condyle was 2.85 mm and 1.51 mm, respectively, increasing valgus predilection. CONCLUSIONS: Caliper measured resection kinematically aligned techniques will position the femoral component in a significantly more valgus position than when aligning to the CA of the knee. This is due to an increased offset of the distal femoral articulation from the most distal aspect of the cylinder on the medial side of the knee. Elsevier 2021-03-23 /pmc/articles/PMC7994728/ /pubmed/33786354 http://dx.doi.org/10.1016/j.artd.2021.02.014 Text en © 2021 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Drynan, David
Rasouli, Rabi Faisal
Williams, James W.A.
Balalla, Buddhika
Measured Resection Techniques Do Not Align to the Cylindrical Axis in Kinematic Total Knee Arthroplasty
title Measured Resection Techniques Do Not Align to the Cylindrical Axis in Kinematic Total Knee Arthroplasty
title_full Measured Resection Techniques Do Not Align to the Cylindrical Axis in Kinematic Total Knee Arthroplasty
title_fullStr Measured Resection Techniques Do Not Align to the Cylindrical Axis in Kinematic Total Knee Arthroplasty
title_full_unstemmed Measured Resection Techniques Do Not Align to the Cylindrical Axis in Kinematic Total Knee Arthroplasty
title_short Measured Resection Techniques Do Not Align to the Cylindrical Axis in Kinematic Total Knee Arthroplasty
title_sort measured resection techniques do not align to the cylindrical axis in kinematic total knee arthroplasty
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7994728/
https://www.ncbi.nlm.nih.gov/pubmed/33786354
http://dx.doi.org/10.1016/j.artd.2021.02.014
work_keys_str_mv AT drynandavid measuredresectiontechniquesdonotaligntothecylindricalaxisinkinematictotalkneearthroplasty
AT rasoulirabifaisal measuredresectiontechniquesdonotaligntothecylindricalaxisinkinematictotalkneearthroplasty
AT williamsjameswa measuredresectiontechniquesdonotaligntothecylindricalaxisinkinematictotalkneearthroplasty
AT balallabuddhika measuredresectiontechniquesdonotaligntothecylindricalaxisinkinematictotalkneearthroplasty