Design and validation of a mechanically flexible and ultra-lightweight high-density diffuse optical tomography system for functional neuroimaging of newborns

Significance: Neonates are a highly vulnerable population. The risk of brain injury is greater during the first days and weeks after birth than at any other time of life. Functional neuroimaging that can be performed longitudinally and at the cot-side has the potential to improve our understanding o...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Hubin, Frijia, Elisabetta M., Vidal Rosas, Ernesto, Collins-Jones, Liam, Smith, Greg, Nixon-Hill, Reuben, Powell, Samuel, Everdell, Nicholas L., Cooper, Robert J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Photo-Optical Instrumentation Engineers 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7995199/
https://www.ncbi.nlm.nih.gov/pubmed/33778094
http://dx.doi.org/10.1117/1.NPh.8.1.015011
_version_ 1783669879154409472
author Zhao, Hubin
Frijia, Elisabetta M.
Vidal Rosas, Ernesto
Collins-Jones, Liam
Smith, Greg
Nixon-Hill, Reuben
Powell, Samuel
Everdell, Nicholas L.
Cooper, Robert J.
author_facet Zhao, Hubin
Frijia, Elisabetta M.
Vidal Rosas, Ernesto
Collins-Jones, Liam
Smith, Greg
Nixon-Hill, Reuben
Powell, Samuel
Everdell, Nicholas L.
Cooper, Robert J.
author_sort Zhao, Hubin
collection PubMed
description Significance: Neonates are a highly vulnerable population. The risk of brain injury is greater during the first days and weeks after birth than at any other time of life. Functional neuroimaging that can be performed longitudinally and at the cot-side has the potential to improve our understanding of the evolution of multiple forms of neurological injury over the perinatal period. However, existing technologies make it very difficult to perform repeated and/or long-duration functional neuroimaging experiments at the cot-side. Aim: We aimed to create a modular, high-density diffuse optical tomography (HD-DOT) technology specifically for neonatal applications that is ultra-lightweight, low profile and provides high mechanical flexibility. We then sought to validate this technology using an anatomically accurate dynamic phantom. Approach: An advanced 10-layer rigid-flexible printed circuit board technology was adopted as the basis for the DOT modules, which allows for a compact module design that also provides the flexibility needed to conform to the curved infant scalp. Two module layouts were implemented: dual-hexagon and triple-hexagon. Using in-built board-to-board connectors, the system can be configured to provide a vast range of possible layouts. Using epoxy resin, thermochromic dyes, and MRI-derived 3D-printed moulds, we constructed an electrically switchable, anatomically accurate dynamic phantom. This phantom was used to quantify the imaging performance of our flexible, modular HD-DOT system. Results: Using one particular module configuration designed to cover the infant sensorimotor system, the device provided 36 source and 48 detector positions, and over 700 viable DOT channels per wavelength, ranging from 10 to [Formula: see text] over an area of approximately [Formula: see text]. The total weight of this system is only 70 g. The signal changes from the dynamic phantom, while slow, closely simulated real hemodynamic response functions. Using difference images obtained from the phantom, the measured 3D localization error provided by the system at the depth of the cortex was in the of range 3 to 6 mm, and the lateral image resolution at the depth of the neonatal cortex is estimated to be as good as 10 to 12 mm. Conclusions: The HD-DOT system described is ultra-low weight, low profile, can conform to the infant scalp, and provides excellent imaging performance. It is expected that this device will make functional neuroimaging of the neonatal brain at the cot-side significantly more practical and effective.
format Online
Article
Text
id pubmed-7995199
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Society of Photo-Optical Instrumentation Engineers
record_format MEDLINE/PubMed
spelling pubmed-79951992021-03-26 Design and validation of a mechanically flexible and ultra-lightweight high-density diffuse optical tomography system for functional neuroimaging of newborns Zhao, Hubin Frijia, Elisabetta M. Vidal Rosas, Ernesto Collins-Jones, Liam Smith, Greg Nixon-Hill, Reuben Powell, Samuel Everdell, Nicholas L. Cooper, Robert J. Neurophotonics Research Papers Significance: Neonates are a highly vulnerable population. The risk of brain injury is greater during the first days and weeks after birth than at any other time of life. Functional neuroimaging that can be performed longitudinally and at the cot-side has the potential to improve our understanding of the evolution of multiple forms of neurological injury over the perinatal period. However, existing technologies make it very difficult to perform repeated and/or long-duration functional neuroimaging experiments at the cot-side. Aim: We aimed to create a modular, high-density diffuse optical tomography (HD-DOT) technology specifically for neonatal applications that is ultra-lightweight, low profile and provides high mechanical flexibility. We then sought to validate this technology using an anatomically accurate dynamic phantom. Approach: An advanced 10-layer rigid-flexible printed circuit board technology was adopted as the basis for the DOT modules, which allows for a compact module design that also provides the flexibility needed to conform to the curved infant scalp. Two module layouts were implemented: dual-hexagon and triple-hexagon. Using in-built board-to-board connectors, the system can be configured to provide a vast range of possible layouts. Using epoxy resin, thermochromic dyes, and MRI-derived 3D-printed moulds, we constructed an electrically switchable, anatomically accurate dynamic phantom. This phantom was used to quantify the imaging performance of our flexible, modular HD-DOT system. Results: Using one particular module configuration designed to cover the infant sensorimotor system, the device provided 36 source and 48 detector positions, and over 700 viable DOT channels per wavelength, ranging from 10 to [Formula: see text] over an area of approximately [Formula: see text]. The total weight of this system is only 70 g. The signal changes from the dynamic phantom, while slow, closely simulated real hemodynamic response functions. Using difference images obtained from the phantom, the measured 3D localization error provided by the system at the depth of the cortex was in the of range 3 to 6 mm, and the lateral image resolution at the depth of the neonatal cortex is estimated to be as good as 10 to 12 mm. Conclusions: The HD-DOT system described is ultra-low weight, low profile, can conform to the infant scalp, and provides excellent imaging performance. It is expected that this device will make functional neuroimaging of the neonatal brain at the cot-side significantly more practical and effective. Society of Photo-Optical Instrumentation Engineers 2021-03-26 2021-01 /pmc/articles/PMC7995199/ /pubmed/33778094 http://dx.doi.org/10.1117/1.NPh.8.1.015011 Text en © 2021 The Authors https://creativecommons.org/licenses/by/4.0/ Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
spellingShingle Research Papers
Zhao, Hubin
Frijia, Elisabetta M.
Vidal Rosas, Ernesto
Collins-Jones, Liam
Smith, Greg
Nixon-Hill, Reuben
Powell, Samuel
Everdell, Nicholas L.
Cooper, Robert J.
Design and validation of a mechanically flexible and ultra-lightweight high-density diffuse optical tomography system for functional neuroimaging of newborns
title Design and validation of a mechanically flexible and ultra-lightweight high-density diffuse optical tomography system for functional neuroimaging of newborns
title_full Design and validation of a mechanically flexible and ultra-lightweight high-density diffuse optical tomography system for functional neuroimaging of newborns
title_fullStr Design and validation of a mechanically flexible and ultra-lightweight high-density diffuse optical tomography system for functional neuroimaging of newborns
title_full_unstemmed Design and validation of a mechanically flexible and ultra-lightweight high-density diffuse optical tomography system for functional neuroimaging of newborns
title_short Design and validation of a mechanically flexible and ultra-lightweight high-density diffuse optical tomography system for functional neuroimaging of newborns
title_sort design and validation of a mechanically flexible and ultra-lightweight high-density diffuse optical tomography system for functional neuroimaging of newborns
topic Research Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7995199/
https://www.ncbi.nlm.nih.gov/pubmed/33778094
http://dx.doi.org/10.1117/1.NPh.8.1.015011
work_keys_str_mv AT zhaohubin designandvalidationofamechanicallyflexibleandultralightweighthighdensitydiffuseopticaltomographysystemforfunctionalneuroimagingofnewborns
AT frijiaelisabettam designandvalidationofamechanicallyflexibleandultralightweighthighdensitydiffuseopticaltomographysystemforfunctionalneuroimagingofnewborns
AT vidalrosasernesto designandvalidationofamechanicallyflexibleandultralightweighthighdensitydiffuseopticaltomographysystemforfunctionalneuroimagingofnewborns
AT collinsjonesliam designandvalidationofamechanicallyflexibleandultralightweighthighdensitydiffuseopticaltomographysystemforfunctionalneuroimagingofnewborns
AT smithgreg designandvalidationofamechanicallyflexibleandultralightweighthighdensitydiffuseopticaltomographysystemforfunctionalneuroimagingofnewborns
AT nixonhillreuben designandvalidationofamechanicallyflexibleandultralightweighthighdensitydiffuseopticaltomographysystemforfunctionalneuroimagingofnewborns
AT powellsamuel designandvalidationofamechanicallyflexibleandultralightweighthighdensitydiffuseopticaltomographysystemforfunctionalneuroimagingofnewborns
AT everdellnicholasl designandvalidationofamechanicallyflexibleandultralightweighthighdensitydiffuseopticaltomographysystemforfunctionalneuroimagingofnewborns
AT cooperrobertj designandvalidationofamechanicallyflexibleandultralightweighthighdensitydiffuseopticaltomographysystemforfunctionalneuroimagingofnewborns