Cargando…
Validation of SYBR green I based closed‐tube loop‐mediated isothermal amplification (LAMP) assay for diagnosis of knowlesi malaria
BACKGROUND: As an alternative to PCR methods, LAMP is increasingly being used in the field of molecular diagnostics. Under isothermal conditions at 65 °C, the entire procedure takes approximately 30 min to complete. In this study, we establish a sensitive and visualized LAMP method in a closed-tube...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7995794/ https://www.ncbi.nlm.nih.gov/pubmed/33766038 http://dx.doi.org/10.1186/s12936-021-03707-0 |
_version_ | 1783669981947363328 |
---|---|
author | Lai, Meng Yee Ooi, Choo Huck Lau, Yee Ling |
author_facet | Lai, Meng Yee Ooi, Choo Huck Lau, Yee Ling |
author_sort | Lai, Meng Yee |
collection | PubMed |
description | BACKGROUND: As an alternative to PCR methods, LAMP is increasingly being used in the field of molecular diagnostics. Under isothermal conditions at 65 °C, the entire procedure takes approximately 30 min to complete. In this study, we establish a sensitive and visualized LAMP method in a closed-tube system for the detection of Plasmodium knowlesi. METHODS: A total of 71 malaria microscopy positive blood samples collected in blood spots were obtained from the Sarawak State Health Department. Using 18s rRNA as the target gene, nested PCR and SYBR green I LAMP assay were performed following the DNA extraction. The colour changes of LAMP end products were observed by naked eyes. RESULTS: LAMP assay demonstrated a detection limit of 10 copies/µL in comparison with 100 copies/µL nested PCR. Of 71 P. knowlesi blood samples collected, LAMP detected 69 microscopy-positive samples. LAMP exhibited higher sensitivity than nested PCR assay. The SYBR green I LAMP assay was 97.1% sensitive (95% CI 90.2–99.7%) and 100% specific (95% CI 83.2–100%). Without opening the cap, incorporation of SYBR green I into the inner cap of the tube enabled the direct visualization of results upon completion of amplification. The positives instantaneously turned green while the negatives remained orange. CONCLUSIONS: These results indicate that SYBR green I LAMP assay is a convenient diagnosis tool for the detection of P. knowlesi in remote settings. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12936-021-03707-0. |
format | Online Article Text |
id | pubmed-7995794 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-79957942021-03-30 Validation of SYBR green I based closed‐tube loop‐mediated isothermal amplification (LAMP) assay for diagnosis of knowlesi malaria Lai, Meng Yee Ooi, Choo Huck Lau, Yee Ling Malar J Research BACKGROUND: As an alternative to PCR methods, LAMP is increasingly being used in the field of molecular diagnostics. Under isothermal conditions at 65 °C, the entire procedure takes approximately 30 min to complete. In this study, we establish a sensitive and visualized LAMP method in a closed-tube system for the detection of Plasmodium knowlesi. METHODS: A total of 71 malaria microscopy positive blood samples collected in blood spots were obtained from the Sarawak State Health Department. Using 18s rRNA as the target gene, nested PCR and SYBR green I LAMP assay were performed following the DNA extraction. The colour changes of LAMP end products were observed by naked eyes. RESULTS: LAMP assay demonstrated a detection limit of 10 copies/µL in comparison with 100 copies/µL nested PCR. Of 71 P. knowlesi blood samples collected, LAMP detected 69 microscopy-positive samples. LAMP exhibited higher sensitivity than nested PCR assay. The SYBR green I LAMP assay was 97.1% sensitive (95% CI 90.2–99.7%) and 100% specific (95% CI 83.2–100%). Without opening the cap, incorporation of SYBR green I into the inner cap of the tube enabled the direct visualization of results upon completion of amplification. The positives instantaneously turned green while the negatives remained orange. CONCLUSIONS: These results indicate that SYBR green I LAMP assay is a convenient diagnosis tool for the detection of P. knowlesi in remote settings. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12936-021-03707-0. BioMed Central 2021-03-25 /pmc/articles/PMC7995794/ /pubmed/33766038 http://dx.doi.org/10.1186/s12936-021-03707-0 Text en © The Author(s) 2021, Corrected publication 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Lai, Meng Yee Ooi, Choo Huck Lau, Yee Ling Validation of SYBR green I based closed‐tube loop‐mediated isothermal amplification (LAMP) assay for diagnosis of knowlesi malaria |
title | Validation of SYBR green I based closed‐tube loop‐mediated isothermal amplification (LAMP) assay for diagnosis of knowlesi malaria |
title_full | Validation of SYBR green I based closed‐tube loop‐mediated isothermal amplification (LAMP) assay for diagnosis of knowlesi malaria |
title_fullStr | Validation of SYBR green I based closed‐tube loop‐mediated isothermal amplification (LAMP) assay for diagnosis of knowlesi malaria |
title_full_unstemmed | Validation of SYBR green I based closed‐tube loop‐mediated isothermal amplification (LAMP) assay for diagnosis of knowlesi malaria |
title_short | Validation of SYBR green I based closed‐tube loop‐mediated isothermal amplification (LAMP) assay for diagnosis of knowlesi malaria |
title_sort | validation of sybr green i based closed‐tube loop‐mediated isothermal amplification (lamp) assay for diagnosis of knowlesi malaria |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7995794/ https://www.ncbi.nlm.nih.gov/pubmed/33766038 http://dx.doi.org/10.1186/s12936-021-03707-0 |
work_keys_str_mv | AT laimengyee validationofsybrgreenibasedclosedtubeloopmediatedisothermalamplificationlampassayfordiagnosisofknowlesimalaria AT ooichoohuck validationofsybrgreenibasedclosedtubeloopmediatedisothermalamplificationlampassayfordiagnosisofknowlesimalaria AT lauyeeling validationofsybrgreenibasedclosedtubeloopmediatedisothermalamplificationlampassayfordiagnosisofknowlesimalaria |