Cargando…
Development of an In Vitro Blink Model for Ophthalmic Drug Delivery
Purpose: The purpose of this study was to develop an advanced in vitro blink model that can be used to examine the release of a wide variety of components (for example, topical ophthalmic drugs, comfort-inducing agents) from soft contact lenses. Methods: The model was designed using computer-aided d...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7996515/ https://www.ncbi.nlm.nih.gov/pubmed/33668884 http://dx.doi.org/10.3390/pharmaceutics13030300 |
_version_ | 1783670120037482496 |
---|---|
author | Phan, Chau-Minh Shukla, Manish Walther, Hendrik Heynen, Miriam Suh, David Jones, Lyndon |
author_facet | Phan, Chau-Minh Shukla, Manish Walther, Hendrik Heynen, Miriam Suh, David Jones, Lyndon |
author_sort | Phan, Chau-Minh |
collection | PubMed |
description | Purpose: The purpose of this study was to develop an advanced in vitro blink model that can be used to examine the release of a wide variety of components (for example, topical ophthalmic drugs, comfort-inducing agents) from soft contact lenses. Methods: The model was designed using computer-aided design software and printed using a stereolithography 3D printer. The eyelid and eyeball were synthesized from polyvinyl alcohol and silicone material, respectively. Simulated tear fluid was infused through tubing attached to the eyelid using a syringe pump. With each blink cycle, the eyelid slides and flexes across the eyeball to create an artificial tear film layer. The flow-through fluid was collected using a specialized trough. Two contact lenses, etafilcon A and senofilcon A, were incubated in 2 mL of a water-soluble red dye for 24 h and then placed on the eye model (n = 3). The release of the dye was measured over 24 h using a tear flow rate of 5 µL/min. Results: Approximately 25% of the fluid that flowed over the eye model was lost due to evaporation, nonspecific absorption, and residual dead volume. Senofilcon A absorbed more dye (47.6 ± 2.7 µL) than etafilcon A (22.3 ± 2.0 µL). For etafilcon A, the release of the dye followed a burst-plateau profile in the vial but was sustained in the eye model. For senofilcon A, the release of the dye was sustained in both the vial and the eye model, though more dye was released in the vial (p < 0.05). Overall, the release of the dye from the contact lenses was higher in the vial compared with the eye model (p < 0.05). Conclusion: The blink model developed in this study could be used to measure the release of topical ophthalmic drugs or comfort agents from contact lenses. Simulation of a blink mechanism, an artificial tear film, and nonspecific absorption in an eye model may provide better results than a simple, static vial incubation model. |
format | Online Article Text |
id | pubmed-7996515 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-79965152021-03-27 Development of an In Vitro Blink Model for Ophthalmic Drug Delivery Phan, Chau-Minh Shukla, Manish Walther, Hendrik Heynen, Miriam Suh, David Jones, Lyndon Pharmaceutics Article Purpose: The purpose of this study was to develop an advanced in vitro blink model that can be used to examine the release of a wide variety of components (for example, topical ophthalmic drugs, comfort-inducing agents) from soft contact lenses. Methods: The model was designed using computer-aided design software and printed using a stereolithography 3D printer. The eyelid and eyeball were synthesized from polyvinyl alcohol and silicone material, respectively. Simulated tear fluid was infused through tubing attached to the eyelid using a syringe pump. With each blink cycle, the eyelid slides and flexes across the eyeball to create an artificial tear film layer. The flow-through fluid was collected using a specialized trough. Two contact lenses, etafilcon A and senofilcon A, were incubated in 2 mL of a water-soluble red dye for 24 h and then placed on the eye model (n = 3). The release of the dye was measured over 24 h using a tear flow rate of 5 µL/min. Results: Approximately 25% of the fluid that flowed over the eye model was lost due to evaporation, nonspecific absorption, and residual dead volume. Senofilcon A absorbed more dye (47.6 ± 2.7 µL) than etafilcon A (22.3 ± 2.0 µL). For etafilcon A, the release of the dye followed a burst-plateau profile in the vial but was sustained in the eye model. For senofilcon A, the release of the dye was sustained in both the vial and the eye model, though more dye was released in the vial (p < 0.05). Overall, the release of the dye from the contact lenses was higher in the vial compared with the eye model (p < 0.05). Conclusion: The blink model developed in this study could be used to measure the release of topical ophthalmic drugs or comfort agents from contact lenses. Simulation of a blink mechanism, an artificial tear film, and nonspecific absorption in an eye model may provide better results than a simple, static vial incubation model. MDPI 2021-02-25 /pmc/articles/PMC7996515/ /pubmed/33668884 http://dx.doi.org/10.3390/pharmaceutics13030300 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ). |
spellingShingle | Article Phan, Chau-Minh Shukla, Manish Walther, Hendrik Heynen, Miriam Suh, David Jones, Lyndon Development of an In Vitro Blink Model for Ophthalmic Drug Delivery |
title | Development of an In Vitro Blink Model for Ophthalmic Drug Delivery |
title_full | Development of an In Vitro Blink Model for Ophthalmic Drug Delivery |
title_fullStr | Development of an In Vitro Blink Model for Ophthalmic Drug Delivery |
title_full_unstemmed | Development of an In Vitro Blink Model for Ophthalmic Drug Delivery |
title_short | Development of an In Vitro Blink Model for Ophthalmic Drug Delivery |
title_sort | development of an in vitro blink model for ophthalmic drug delivery |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7996515/ https://www.ncbi.nlm.nih.gov/pubmed/33668884 http://dx.doi.org/10.3390/pharmaceutics13030300 |
work_keys_str_mv | AT phanchauminh developmentofaninvitroblinkmodelforophthalmicdrugdelivery AT shuklamanish developmentofaninvitroblinkmodelforophthalmicdrugdelivery AT waltherhendrik developmentofaninvitroblinkmodelforophthalmicdrugdelivery AT heynenmiriam developmentofaninvitroblinkmodelforophthalmicdrugdelivery AT suhdavid developmentofaninvitroblinkmodelforophthalmicdrugdelivery AT joneslyndon developmentofaninvitroblinkmodelforophthalmicdrugdelivery |