Cargando…
Comparing a deep learning model's diagnostic performance to that of radiologists to detect Covid -19 features on chest radiographs
BACKGROUND: Whether the sensitivity of Deep Learning (DL) models to screen chest radiographs (CXR) for CoVID-19 can approximate that of radiologists, so that they can be adopted and used if real-time review of CXRs by radiologists is not possible, has not been explored before. OBJECTIVE: To evaluate...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7996677/ https://www.ncbi.nlm.nih.gov/pubmed/33814762 http://dx.doi.org/10.4103/ijri.IJRI_914_20 |
Sumario: | BACKGROUND: Whether the sensitivity of Deep Learning (DL) models to screen chest radiographs (CXR) for CoVID-19 can approximate that of radiologists, so that they can be adopted and used if real-time review of CXRs by radiologists is not possible, has not been explored before. OBJECTIVE: To evaluate the diagnostic performance of a doctor-trained DL model (Svita_DL8) to screen for COVID-19 on CXR, and to compare the performance of the DL model with that of expert radiologists. MATERIALS AND METHODS: We used a pre-trained convolutional neural network to develop a publicly available online DL model to evaluate CXR examinations saved in .jpeg or .png format. The initial model was subsequently curated and trained by an internist and a radiologist using 1062 chest radiographs to classify a submitted CXR as either normal, COVID-19, or a non-COVID-19 abnormal. For validation, we collected a separate set of 430 CXR examinations from numerous publicly available datasets from 10 different countries, case presentations, and two hospital repositories. These examinations were assessed for COVID-19 by the DL model and by two independent radiologists. Diagnostic performance was compared between the model and the radiologists and the correlation coefficient calculated. RESULTS: For detecting COVID-19 on CXR, our DL model demonstrated sensitivity of 91.5%, specificity of 55.3%, PPV 60.9%, NPV 77.9%, accuracy 70.1%, and AUC 0.73 (95% CI: 0.86, 0.95). There was a significant correlation (r = 0.617, P = 0.000) between the results of the DL model and the radiologists’ interpretations. The sensitivity of the radiologists is 96% and their overall diagnostic accuracy is 90% in this study. CONCLUSIONS: The DL model demonstrated high sensitivity for detecting COVID-19 on CXR. CLINICAL IMPACT: The doctor trained DL tool Svita_DL8 can be used in resource-constrained settings to quickly triage patients with suspected COVID-19 for further in-depth review and testing. |
---|