Cargando…

Influence of Sequential CAD/CAM Milling on the Fitting Accuracy of Titanium Three-Unit Fixed Dental Prostheses

This study investigated the fitting accuracy of titanium alloy fixed dental prostheses (FDP) after sequential CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) fabrication. A three-unit FDP model connecting mandibular second premolars and molars was prepared and scanned to fabricate titan...

Descripción completa

Detalles Bibliográficos
Autores principales: Song, Doo-Bin, Han, Man-So, Kim, Si-Chul, Ahn, Junyong, Im, Yong-Woon, Lee, Hae-Hyoung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7998422/
https://www.ncbi.nlm.nih.gov/pubmed/33805802
http://dx.doi.org/10.3390/ma14061401
_version_ 1783670548501364736
author Song, Doo-Bin
Han, Man-So
Kim, Si-Chul
Ahn, Junyong
Im, Yong-Woon
Lee, Hae-Hyoung
author_facet Song, Doo-Bin
Han, Man-So
Kim, Si-Chul
Ahn, Junyong
Im, Yong-Woon
Lee, Hae-Hyoung
author_sort Song, Doo-Bin
collection PubMed
description This study investigated the fitting accuracy of titanium alloy fixed dental prostheses (FDP) after sequential CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) fabrication. A three-unit FDP model connecting mandibular second premolars and molars was prepared and scanned to fabricate titanium FDPs by CAD/CAM milling. A total of six FDPs were sequentially milled in one titanium alloy disk using a new set of burs every time (n = 4). The fitting accuracy of FDPs was mesiodistally evaluated by a silicone replica technique and the measurement was triplicated at four different locations: MO (marginal opening), MG (marginal gap), AG (axial gap), and OG (occlusal gap). Data were statistically analyzed using ANOVA and Tukey’s HSD test. The fitting accuracy of PMMA (polymethyl methacrylate) FDPs milled using the worn or new bur were evaluated by the same procedure (n = 6). The mean dimensions of titanium FDP for all measuring positions, except for AG, were significantly increased from the third milling. However, no difference was noted between the first FDP and the second FDP milled with the same set of burs. Severe edge chippings were observed in all milling burs. Detrimental effects of the worn burs on the fitting accuracy were demonstrated in the CAD/CAM-milled PMMA FDP. The results recommend proper changing frequency of cutting burs to achieve the quality of fit and predictable outcomes for dental CAD/CAM prostheses.
format Online
Article
Text
id pubmed-7998422
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-79984222021-03-28 Influence of Sequential CAD/CAM Milling on the Fitting Accuracy of Titanium Three-Unit Fixed Dental Prostheses Song, Doo-Bin Han, Man-So Kim, Si-Chul Ahn, Junyong Im, Yong-Woon Lee, Hae-Hyoung Materials (Basel) Article This study investigated the fitting accuracy of titanium alloy fixed dental prostheses (FDP) after sequential CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) fabrication. A three-unit FDP model connecting mandibular second premolars and molars was prepared and scanned to fabricate titanium FDPs by CAD/CAM milling. A total of six FDPs were sequentially milled in one titanium alloy disk using a new set of burs every time (n = 4). The fitting accuracy of FDPs was mesiodistally evaluated by a silicone replica technique and the measurement was triplicated at four different locations: MO (marginal opening), MG (marginal gap), AG (axial gap), and OG (occlusal gap). Data were statistically analyzed using ANOVA and Tukey’s HSD test. The fitting accuracy of PMMA (polymethyl methacrylate) FDPs milled using the worn or new bur were evaluated by the same procedure (n = 6). The mean dimensions of titanium FDP for all measuring positions, except for AG, were significantly increased from the third milling. However, no difference was noted between the first FDP and the second FDP milled with the same set of burs. Severe edge chippings were observed in all milling burs. Detrimental effects of the worn burs on the fitting accuracy were demonstrated in the CAD/CAM-milled PMMA FDP. The results recommend proper changing frequency of cutting burs to achieve the quality of fit and predictable outcomes for dental CAD/CAM prostheses. MDPI 2021-03-13 /pmc/articles/PMC7998422/ /pubmed/33805802 http://dx.doi.org/10.3390/ma14061401 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Song, Doo-Bin
Han, Man-So
Kim, Si-Chul
Ahn, Junyong
Im, Yong-Woon
Lee, Hae-Hyoung
Influence of Sequential CAD/CAM Milling on the Fitting Accuracy of Titanium Three-Unit Fixed Dental Prostheses
title Influence of Sequential CAD/CAM Milling on the Fitting Accuracy of Titanium Three-Unit Fixed Dental Prostheses
title_full Influence of Sequential CAD/CAM Milling on the Fitting Accuracy of Titanium Three-Unit Fixed Dental Prostheses
title_fullStr Influence of Sequential CAD/CAM Milling on the Fitting Accuracy of Titanium Three-Unit Fixed Dental Prostheses
title_full_unstemmed Influence of Sequential CAD/CAM Milling on the Fitting Accuracy of Titanium Three-Unit Fixed Dental Prostheses
title_short Influence of Sequential CAD/CAM Milling on the Fitting Accuracy of Titanium Three-Unit Fixed Dental Prostheses
title_sort influence of sequential cad/cam milling on the fitting accuracy of titanium three-unit fixed dental prostheses
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7998422/
https://www.ncbi.nlm.nih.gov/pubmed/33805802
http://dx.doi.org/10.3390/ma14061401
work_keys_str_mv AT songdoobin influenceofsequentialcadcammillingonthefittingaccuracyoftitaniumthreeunitfixeddentalprostheses
AT hanmanso influenceofsequentialcadcammillingonthefittingaccuracyoftitaniumthreeunitfixeddentalprostheses
AT kimsichul influenceofsequentialcadcammillingonthefittingaccuracyoftitaniumthreeunitfixeddentalprostheses
AT ahnjunyong influenceofsequentialcadcammillingonthefittingaccuracyoftitaniumthreeunitfixeddentalprostheses
AT imyongwoon influenceofsequentialcadcammillingonthefittingaccuracyoftitaniumthreeunitfixeddentalprostheses
AT leehaehyoung influenceofsequentialcadcammillingonthefittingaccuracyoftitaniumthreeunitfixeddentalprostheses